BS IEC 61156-9:2016
Current
The latest, up-to-date edition.
Multicore and symmetrical pair/quad cables for digital communications Cables for channels with transmission characteristics up to 2 GHz. Sectional specification
30-04-2016
Committee |
EPL/46
|
DevelopmentNote |
Supersedes 14/30296057 DC. (07/2016)
|
DocumentType |
Standard
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of IEC61156 describes cables primarily intended for the fixed part of channels as defined in ISO/IEC11801 and in ISO/IECTR11801‑9901 which is planned to be included in the next edition of ISO/IEC11801‑1 . It covers overall screened cables with screened (X/FTP) or unscreened (X/UTP) pairs, where X stands for F, S or SF, as well as pair-screened cables without overall screen (U/FTP). The transmission characteristics of these cables are specified up to a frequency of 2000MHz and at a temperature of 20°C. Two categories of cables are recognised: Category8.1 for use in Class I according to ISO/IECTR11801‑9901 ; Category8.2 for use in Class II according to ISO/IECTR11801‑9901 . These cables are intended to be used for communication channels which use at least four pairs simultaneously. The cables covered by this International Standard are intended to operate with voltages and currents normally encountered in communication systems. While these cables are not intended to be used in conjunction with low impedance sources, e.g. the electric power supplies of public utility mains, they are intended to be used to support the delivery of low voltage remote powering applications such as IEEE802.3af (Power over Ethernet) or further developments e.g. according to IEEE802.3at or IEEE802.3bt. More information on the capacity to support these applications according to the installation practices is given in IECPAS61156‑1‑4 , IECTR61156‑1‑6 and ISO/IECTR29125 .
Standards | Relationship |
IEC 61156-9:2016 | Identical |
IEC TR 61156-1-2:2009+AMD1:2014 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1-2: Electrical transmission characteristicsand test methods of symmetrical pair/quad cables |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
ISO/IEC TR 11801-9901:2014 | Information technology Generic cabling systems for customer premises Part 9901: Guidance for balanced cabling in support of at least 40 Gbit/s data transmission |
IEC PAS 61156-1-4:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 1-4: Symmetrical pair/quad cables with transmission characteristics up to 1 000 MHz - Conductor heating of bundled data grade cables for limited power transmission based on IEEE 802.3 |
IEC TR 61156-1-5:2013 | Multicore and symmetrical pair/quad cables for digital communications - Part 1-5: Correction procedures for the measurement results of return loss and input impedance |
ISO/IEC TR 29125:2010 | Information technology Telecommunications cabling requirements for remote powering of terminal equipment |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
IEC 62153-4-5:2006 | Metallic communication cables test methods - Part 4-5: Electromagnetic compatibility (EMC) - Coupling or screening attenuation - Absorbing clamp method |
IEC 62153-4-9:2008 | Metallic communication cable test methods - Part 4-9: Electromagnetic compatibility (EMC) - Coupling attenuation of screened balanced cables, triaxial method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.