• BS IEC 61467:1997

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Insulators for overhead lines with a nominal voltage above 1000 V. AC power arc tests on insulator sets

    Available format(s):  Hardcopy, PDF

    Superseded date:  31-03-2009

    Language(s):  English

    Published date:  15-05-1999

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    1 Scope and object
    2 Normative references
    3 Definitions
    4 Symbols and abbreviations
    5 Test arrangement
    6 Test current
    7 Supply and return circuit conditions
    8 Arc initiation
    9 Ambient conditions
    10 Test series and characteristics of the power arcs
    11 Test report
    12 Evaluation of results
        12.1 Visual examination
        12.2 Porcelain or glass insulators
        12.3 Composite insulators
        12.4 Acceptance criteria
    TABLES
    1 Supply and return conditions
    2 Test series
    3 Test assessment criteria
    FIGURES
    1 Illustration of supply and return currents
    2 Arc initiation
    ANNEXES
    A Test arrangements and practical methods of tower simulation
        (return circuit)
    B Determination of the r.m.s. value of the current
    C No-load voltage of the power source
    D Power arcs on insulator sets and their true simulation by appropriate
        positioning of fusible wires
    E Wind velocity during power arc tests
    F Variation of the fault current magnitude and reasons for the choice
        of the prescribed test parameters
    G Recommendations for the test report
    H Sample of a power arc test report

    Abstract - (Show below) - (Hide below)

    Defines insulator sets comprising string insulator units of ceramic material, glass or composite material for use on a.c. overhead lines and traction lines with a nominal voltage above 1 000 V and a frequency between 15 Hz and 100 Hz. Applicable to insulator sets of similar design used in substations. Not applicable to mounted on non-metallic poles or towers.

    General Product Information - (Show below) - (Hide below)

    Committee PEL/36
    Document Type Standard
    Publisher British Standards Institution
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
    IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
    IEC 60383-2:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective