BS IEC 62153-4-6:2017
Current
The latest, up-to-date edition.
Metallic cables and other passive components test methods Electromagnetic compatibility (EMC). Surface transfer impedance. Line injection method
Hardcopy , PDF
English
18-09-2017
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Physical background
5 Test set-up
6 Preparation of the test sample
7 Measurement
8 Expression of test results
9 Requirement
Bibliography
Describes the screening effectiveness of a shielded metallic communication cable by applying a well-defined current and voltage to the screen of the cable and measuring the induced voltage in order to determine the surface transfer impedance.
| Committee |
EPL/46
|
| DevelopmentNote |
Supersedes 15/30321843 DC. (10/2017)
|
| DocumentType |
Standard
|
| Pages |
26
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of IEC62153 determines the screening effectiveness of a shielded metallic communication cable by applying a well-defined current and voltage to the screen of the cable and measuring the induced voltage in order to determine the surface transfer impedance. Measurements in the frequency range from a few kHz up to and above 1GHz can be made with the use of normal high frequency instrumentation.
| Standards | Relationship |
| IEC 61076-2-106:2011 | Identical |
| IEC 62153-4-6:2017 | Identical |