• There are no items in your cart

BS IEC TR 61334-5.2 : 1998

Current

Current

The latest, up-to-date edition.

DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - PART 5-2: LOWER LAYER PROFILES - FREQUENCY SHIFT KEYING (FSK) PROFILE

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-1998

€254.76
Excluding VAT

FOREWORD
1 General
    1.1 Scope and object
    1.2 Normative references
    1.3 Acronyms
2 The lower layer profile structure
    2.1 MAC sublayer
    2.2 PLS sublayer
    2.3 MAU
3 MAC sublayer
    3.1 Overview
    3.2 Classes of service
          3.2.1 Class of service in connection oriented
                  (CO) mode
          3.2.2 Class of service in connectionless (CL) mode
    3.3 MAC services
    3.4 MAC to LLC interfaces
          3.4.1 MA_Data.request
                  3.4.1.1 Function
                  3.4.1.2 Structure
                  3.4.1.3 Use
          3.4.2 MA_Data.indication
                  3.4.2.1 Function
                  3.4.2.2 Structure
                  3.4.2.3 Use
          3.4.3 MA_Data.confirm
                  3.4.3.1 Function
                  3.4.3.2 Structure
                  3.4.3.3 Use
    3.5 MAC to Physical layer interfaces
    3.6 MAC to Layer Management Interface
          3.6.1 Function
          3.6.2 Structure
          3.6.3 Use
    3.7 MAC frame format
    3.8 MAC frame
    3.9 Elements of the MAC frame
          3.9.1 Preamble
          3.9.2 Flag
          3.9.3 Address
          3.9.4 Control
                  3.9.4.1 Repetition Style 1
                  3.9.4.2 Repetition Style 2
          3.9.5 Repetition
          3.9.6 Information
          3.9.7 Frame Checking Sequence (FCS)
    3.10 MAC invalid frame
    3.11 MAC procedures
          3.11.1 MACph procedures
                  3.11.1.1 Transmit a frame
                  3.11.1.2 Receive a frame
                  3.11.1.3 Detection of the AC phase delay
          3.11.2 MACre procedures
          3.11.3 MAC repetition procedures Style 1
                  3.11.3.1 Service_Class = 1
                  3.11.3.2 Service_Class = 2
          3.11.4 MAC repetition procedures Style 2
    3.12 Repetition management
    3.13 MAC state transition
          3.13.1 State transition table for the operation
                  Style 1
          3.13.2 State description
          3.13.3 Event description
          3.13.4 Actions description
          3.13.5 Notation used in the transition table
4 PLS sublayer
    4.1 PLS service specification
          4.1.1 General description of the service
          4.1.2 Detailed specification of the service
                  4.1.2.1 Ph_Data.request
                  4.1.2.2 Ph_Data.confirm
                  4.1.2.3 Ph_Data.indication
                  4.1.2.4 Ph_ZC.indication
    4.2 Frame structure and synchronization
          4.2.1 Frame structure
          4.2.2 Frame synchronization
    4.3 MI characteristics
          4.3.1 General description of the characteristics
          4.3.2 Detailed description of the signals
                  4.3.2.1 Transmit Data (TD)
                  4.3.2.2 Receive Data (RD)
                  4.3.2.3 Mode Control (MC)
                  4.3.2.4 Bit Clock (BC)
                  4.3.2.5 Zero Crossing (ZC)
    4.4 Description of the procedures
          4.4.1 PLS component state descriptions
          4.4.2 PLS component event descriptions
          4.4.3 PLS component action descriptions
5 MAU
    5.1 General
    5.2 General characteristics
          5.2.1 Modulation rate
          5.2.2 Frequency range
          5.2.3 Optional interchange circuits
    5.3 MV modem characteristics
          5.3.1 Nominal input-output impedance
          5.3.2 Load impedance
          5.3.3 Nominal signal output power
          5.3.4 Nominal signal frequency band (BN)
          5.3.5 Transmission mask
          5.3.6 Carrier stabilization
          5.3.7 Input sensitivity
          5.3.8 Input dynamic range
          5.3.9 Bit error rate
          5.3.10 Recovered clock jitter
    5.4 LV modem characteristics
          5.4.1 Frequency bands
          5.4.2 Input-output impedance
          5.4.3 Load impedance
          5.4.4 Transmission mask
          5.4.5 Signal frequency stabilization
          5.4.6 Input sensitivity
          5.4.7 Input dynamic range
          5.4.8 Bit error rate
          5.4.9 Recovered clock jitter

Covers a lower layer profile which includes the medium access control sublayer, physical signalling sublayer and the mains attachment units, in order to give a contribution to build up a set of standards for effective communication on MV and LV network for distribution line carrier systems.

Committee
PEL/57
DevelopmentNote
Supersedes 92/28106 DC. (06/2005)
DocumentType
Standard
Pages
44
PublisherName
British Standards Institution
Status
Current
Supersedes

IEC 61334-4-32:1996 Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC)
IEC 61334-4-33:1998 Distribution automation using distribution line carrier systems - Part 4-33: Data communication protocols - Data link layer - Connection oriented protocol
ISO/IEC 3309:1993 Information technology — Telecommunications and information exchange between systems — High-level data link control (HDLC) procedures — Frame structure
IEC 61334-3-1:1998 Distribution automation using distribution line carrier systems - Part 3-1: Mains signalling requirements - Frequency bands and output levels
IEC 60495:1993 Single sideband power-line carrier terminals

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.