• Shopping Cart
    There are no items in your cart

BS ISO 11843-5:2008+A1:2017

Current

Current

The latest, up-to-date edition.

Capability of detection Methodology in the linear and non-linear calibration cases

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

24-11-2017

€243.07
Excluding VAT

Committee
SS/6
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Current

This part of ISO11843 is concerned with calibration functions that are either linear or non-linear.

It specifies basic methods to

  • construct a precision profile for the response variable, namely a description of the standard deviation (SD) or coefficient of variation (CV) of the response variable as a function of the net state variable,

  • transform this precision profile into a precision profile for the net state variable in conjunction with the calibration function, and

  • use the latter precision profile to estimate the critical value and minimum detectable value of the net state variable.

The methods described in this part of ISO11843 are useful for checking the detection of a certain substance by various types of measurement equipment to which ISO11843-2 cannot be applied. Included are assays of persistent organic pollutants (POPs) in the environment, such as dioxins, pesticides and hormone-like chemicals, by competitive ELISA (enzyme-linked immunosorbent assay), and tests of bacterial endotoxins that induce hyperthermia in humans.

The definition and applicability of the critical value and minimum detectable value of the net state variable are described in ISO11843-1 and ISO11843-2 . This part of ISO11843 extends the concepts in ISO11843-2 to the cases of non-linear calibration.

The critical value, x c, and minimum detectable value, x d, are both given in the units of the net state variable. If x c and x d are defined based on the distribution for the response variable, the definition should include the calibration function to transform the response variable to the net state variable. This part of ISO11843 defines x c and x d based on the distribution for the net state variable independently of the form of the calibration function. Consequently, the definition is available irrespective of the form of this function, whether it is linear or non-linear.

The calibration function should be continuous, differentiable, and monotonically increasing or decreasing.

A further method is described for the cases where the SD or CV is known only in the neighbourhood of the minimum detectable value.

Examples are provided.

Standards Relationship
ISO 11843-5:2008/Amd 1:2017 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.