BS ISO 15767:2009
Current
The latest, up-to-date edition.
Workplace atmospheres. Controlling and characterizing uncertainty in weighing collected aerosols
Hardcopy , PDF
English
31-07-2009
Foreword
Introduction
1 Scope
2 Terms and definitions
3 Weight instability - Causes and minimization
3.1 General
3.2 Moisture sorption
3.3 Electrostatic effects
3.4 Effects of volatile compounds (other than water)
3.5 Handling damage
3.6 Buoyancy changes
4 Correcting for weight instability by use of blanks
4.1 General
4.2 Minimum number of blanks
4.3 Weighing times and sequence
4.4 Conditioning times
4.5 Storage stability
5 Transport of collection substrates with collected aerosol
samples to laboratory
5.1 General
5.2 Recommended packaging
6 Weighing equipment and procedure
6.1 The balance
6.2 Recommended environmental controls
6.3 Other equipment requirements
6.4 Procedure
7 Recommendations for the reporting of measured mass
relative to LOD and LOQ
8 Estimation of the uncertainty of the analytical procedure
of weighing aerosol collection substrates
8.1 Introduction
8.2 Within-laboratory estimated standard deviation s[w]
obtained over an extended period
9 Measures to assure the validity of previously determined
measurement uncertainty
9.1 Continued determination of within-laboratory
reproducibility
9.2 Participation in laboratory performance proficiency
testing
9.3 Laboratory self-check on weighing uncertainty
Annex A (normative) - Uncertainty component in weighing
collected aerosol
Annex B (informative) - Interpretation of LOD and LOQ
Annex C (informative) - Method evaluation example
Annex D (normative) - Test of transportation integrity
Annex E (informative) - Check on weighing uncertainty
Annex F (informative) - Balance uncertainty
Bibliography
Defines recommendations for controlling the analytical uncertainty associated with aerosol collection medium instability, where collection medium or collection substrate includes any article used to collect particles (e.g. filter or foam material) as well as those supporting elements which must be analysed by weighing.
Committee |
EH/2/2
|
DevelopmentNote |
Supersedes 00/565237 DC. (07/2003) Supersedes 08/30159437 DC. (07/2009)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard provides recommendations for controlling the analytical uncertainty associated with aerosol collection medium instability, where collection medium or collection substrate includes any article used to collect particles (e.g. filter or foam material) as well as those supporting elements which must be analysed by weighing.
This International Standard is applicable to results compiled both from the literature and, if necessary and feasible, through laboratory experiment. Expected uncertainty associated with given aerosol capture methods is quantified where possible. Recommendations as to materials to be used are given. Means of minimizing uncertainty arising from instability are provided. Recommendations for the weighing procedure are given. A procedure for estimating weighing uncertainty is described. Finally, recommendations are given for the reporting of measured mass, including an uncertainty component and limits of detection and quantification.
Standards | Relationship |
ISO 15767:2009 | Identical |
ISO 7708:1995 | Air quality — Particle size fraction definitions for health-related sampling |
EN 482:2012+A1:2015 | Workplace exposure - General requirements for the performance of procedures for the measurement of chemical agents |
NFX 43 257 : 2016 | AIR QUALITY - WORKPLACE AIR - SAMPLING OF AN AEROSOL USING A CLOSED-FACE CARTRIDGE (4 MM OPENING) |
EN 13205:2001 | Workplace atmospheres - Assessment of performance of instruments for measurement of airborne particle concentrations |
ISO 16107:2007 | Workplace atmospheres Protocol for evaluating the performance of diffusive samplers |
UNE 81599:2014 | Workplace exposure. Determination of airborne particles (inhalable, thoracic and respirable fractions). Gravimetric method. |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.