BS ISO 16063-34:2019
Current
The latest, up-to-date edition.
Methods for the calibration of vibration and shock transducers Testing of sensitivity at fixed temperatures
Hardcopy , PDF
English
09-04-2020
This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers.
Committee |
GME/21/5
|
DocumentType |
Standard
|
ISBN |
9780539007565
|
Pages |
24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers. It applies to rectilinear velocity and acceleration transducers.The methods specified use both a comparison to a reference transducer and an absolute measurement by laser interferometer.This document is applicable for a frequency range from 10Hz to 3kHz (method-dependent), a dynamic range from 1m/s2 to 100m/s2 (frequency-dependent) and a temperature range from –1 90°C to 800°C (method-dependent). Although it is possible to achieve these ranges among all the described systems, generally each has limitations within them.Method1 (using a laser interferometer) is applicable to magnitude of sensitivity and phase calibration in the frequency range 10Hz to 3kHz at fixed temperatures (see Clause7). Method2 (using a reference transducer inside a chamber whose temperature limit is –70°C to 500°C) can be used for magnitude of sensitivity and phase calibration in the frequency range 10Hz to 1kHz at fixed temperatures (see Clause8). Method3 (using a reference transducer outside the chamber) can only be used for the determination of the temperature response of complex sensitivity over a certain temperature range (see Clause9). NOTE Method1 and Method2 can provide the deviation of complex sensitivity over a certain temperature range if the calibration is also done at the reference temperature (room temperature 23°C±5°C).To ensure the consistency of the use and test condition, the transducer, its cable and the conditioning amplifier are intended to be considered as a single unit and tested together.
Standards | Relationship |
ISO 16063-34:2019 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.