BS ISO 16063-34:2019

Current

Current

The latest, up-to-date edition.

Methods for the calibration of vibration and shock transducers Testing of sensitivity at fixed temperatures

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

09-04-2020

€217.36
Excluding VAT

This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers.

Committee
GME/21/5
DocumentType
Standard
ISBN
9780539007565
Pages
24
PublisherName
British Standards Institution
Status
Current

This document details specifications for the instrumentation and methods to be used for testing fixed temperature sensitivity of vibration transducers. It applies to rectilinear velocity and acceleration transducers.The methods specified use both a comparison to a reference transducer and an absolute measurement by laser interferometer.This document is applicable for a frequency range from 10Hz to 3kHz (method-dependent), a dynamic range from 1m/s2 to 100m/s2 (frequency-dependent) and a temperature range from –1 90°C to 800°C (method-dependent). Although it is possible to achieve these ranges among all the described systems, generally each has limitations within them.Method1 (using a laser interferometer) is applicable to magnitude of sensitivity and phase calibration in the frequency range 10Hz to 3kHz at fixed temperatures (see Clause7). Method2 (using a reference transducer inside a chamber whose temperature limit is –70°C to 500°C) can be used for magnitude of sensitivity and phase calibration in the frequency range 10Hz to 1kHz at fixed temperatures (see Clause8). Method3 (using a reference transducer outside the chamber) can only be used for the determination of the temperature response of complex sensitivity over a certain temperature range (see Clause9). NOTE Method1 and Method2 can provide the deviation of complex sensitivity over a certain temperature range if the calibration is also done at the reference temperature (room temperature 23°C±5°C).To ensure the consistency of the use and test condition, the transducer, its cable and the conditioning amplifier are intended to be considered as a single unit and tested together.

Standards Relationship
ISO 16063-34:2019 Identical