BS ISO 3966:2020
Current
The latest, up-to-date edition.
Measurement of fluid flow in closed conduits. Velocity area method using Pitot static tubes
Hardcopy , PDF
English
27-07-2020
This document specifies a method for the determination in a closed conduit of the volume rate of flow of a regular flow a) of a fluid of substantially constant density or corresponding to a Mach number not exceeding 0,25, b) with substantially uniform stagnation temperature across the measuring cross-section, c) running full in the conduit, and d) under steady flow conditions.
Committee |
CPI/30/5
|
DocumentType |
Standard
|
ISBN |
9780539000993
|
Pages |
64
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This document specifies a method for the determination in a closed conduit of the volume rate of flow of a regular flow of a fluid of substantially constant density or corresponding to a Mach number not exceeding 0,25, with substantially uniform stagnation temperature across the measuring cross-section, running full in the conduit, and under steady flow conditions. In particular, it deals with the technology and maintenance of Pitot static tubes, with the calculation of local velocities from measured differential pressures and with the computation of the flow rate by velocity integration.