BS ISO 4037-2:1997
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Dosimetry for radiation protection over the energy ranges 8 keV to 1, 3 MeV and 4 MeV to 9 MeV
Hardcopy , PDF
22-02-2021
English
15-03-1998
1 Scope
2 Normative references
3 Definitions
4 Apparatus
5 General procedures
6 Procedures applicable to ionization chambers
7 Additional procedures and precautions specific to
gamma radiation dosimetry using radionuclide sources
8 Additional procedures and precautions specific to
X-radiation dosimetry
9 Special procedures and precautions specific to fluorescence
X-radiation - Limitation of extraneous radiation in beams
10 Dosimetry of reference radiation at photon energies
between 4 MeV and 9 MeV
11 Uncertainty of measurement
Annex A (informative) Determination by ionization chamber
measurements of air kerma under receptorabsent conditions and
of absorbed dose to tissue (water) under receptor conditions
Annex B (informative) Bibliography
Defines methods for dosimetry of X and gamma reference radiation for calibrating radiation protection instruments over the energy range from approximately 8 keV to 1.3 MeV and from 4 MeV to 9 Mev.
Committee |
NCE/2
|
DevelopmentNote |
Supersedes 95/703160 DC and BS 5869(1980). (07/2005) Reviewed and confirmed by BSI, March 2014. (02/2014)
|
DocumentType |
Standard
|
Pages |
34
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 4037-2:1997 | Identical |
DEFSTAN 05-55(PT3)/2(2016) : 2016 | MEASUREMENT AND CALIBRATION SYSTEM REQUIREMENTS FOR MINISTRY OF DEFENCE TEST AND MEASUREMENT EQUIPMENT - PART 3: SUB CONTRACT OF CALIBRATION |
ASTM E 1026 : 2015 : REDLINE | Standard Practice for Using the Fricke Dosimetry System |
IEC 60050-391:1975 | International Electrotechnical Vocabulary (IEV) - Part 391: Detection and measurement of ionizing radiation by electric means |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |
ISO 4037-3:1999 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence |