BS ISO 4037-3:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
Hardcopy , PDF
22-02-2021
English
15-09-1999
1 Scope
2 Normative references
3 Definitions
3.1 Quantities and units
3.2 Calibration factor and response
determination
4 Procedures applicable to all areas and personal
dosemeters
4.1 General principles
4.2 Methods for the determination of the
calibration factor and the response
5 Particular procedures for area dosemeters
5.1 General principles
5.2 Quantities to be measured
5.3 Conversion coefficients
6 Particular procedures for personal dosemeters
6.1 General principles
6.2 Quantities to be measured
6.3 Experimental conditions
6.4 Conversion coefficients
7 Presentation of results
7.1 Records and certificates
7.2 Statement of uncertainties
Annex A (informative) Additional information
Bibliography
Defines the calibration of dosemeters and doserate meters used for individual and for area monitoring in photon reference radiation fields with energies between 8 KeV and 9 MeV. Excludes the in-situ calibration of fixed installed area dosemeters.
Committee |
NCE/2
|
DevelopmentNote |
Supersedes 97/700865 DC. (05/2005)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ISO 4037-3:1999 | Identical |
DEFSTAN 05-55(PT3)/2(2016) : 2016 | MEASUREMENT AND CALIBRATION SYSTEM REQUIREMENTS FOR MINISTRY OF DEFENCE TEST AND MEASUREMENT EQUIPMENT - PART 3: SUB CONTRACT OF CALIBRATION |
ISO 6980:1996 | Reference beta radiations for calibrating dosemeters and dose-rate meters and for determining their response as a function of beta-radiation energy |
ISO 4037-2:1997 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV |
ISO 4037-1:1996 | X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods |