BS ISO 6162-1:2012
Current
The latest, up-to-date edition.
Hydraulic fluid power. Flange connections with split or one-piece flange clamps and metric or inch screws Flange connectors, ports and mounting surfaces for use at pressures of 3,5 MPa (35 bar) to 35 MPa (350 bar), DN 13 to DN 127
Hardcopy , PDF
English
31-12-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Material
5 Selection
6 Dimensions and tolerances
7 Corrosion protection
8 Pressure/temperature requirements
9 Marking
10 Designation of flange connections and
their parts
Annex A (informative) - Recommended assembly
procedures and screw torque levels for
flange connections conforming to ISO 6162-1
Annex B (informative) - O-ring designation codes and
dimensions
Bibliography
Provides general and dimensional specifications for flanged heads, split flange clamps (FCS and FCSM), one-piece flange clamps (FC and FCM), ports and mounting surfaces applicable to four-screw, split and one-piece flange clamp type tube connectors and hose fittings for use at pressures of 3,5 MPa (35 bar) to 35 MPa (350 bar).
| Committee |
MCE/18/-/4
|
| DevelopmentNote |
Supersedes 98/714958 DC. (01/2003) Together with BS ISO 6162-2 supersedes BS 7796(1995). (12/2004) Supersedes 10/30199074 DC. (01/2013)
|
| DocumentType |
Standard
|
| Pages |
32
|
| PublisherName |
British Standards Institution
|
| Status |
Current
|
| Supersedes |
This part of ISO6162 gives general and dimensional specifications for flanged heads, split flange clamps (FCS and FCSM), one-piece flange clamps (FC and FCM), ports and mounting surfaces applicable to four-screw, split and one-piece flange clamp type tube connectors and hose fittings for use at pressures of 3,5MPa (35 bar1)) to 35MPa (350 bar). It also specifies the dimensions of the seals to be used, as well as the grooves that house the seals.
This part of ISO6162 also recognizes the need to accommodate metric screw fasteners (type1), as well as to provide a means to use existing inch screw fasteners (type2).
These connections are intended for application in hydraulic systems on industrial and commercial products where it is desired to avoid the use of threaded connectors.
Surges of pressure higher than the nominal ratings can reduce the ability of the flange connections to retain the hydraulic fluid. This needs to be taken into account in the design of the hydraulic system.
| Standards | Relationship |
| ISO 6162-1:2012 | Identical |