BS ISO 6980-2:2004
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Nuclear energy. Reference beta-particle radiation Calibration fundamentals related to basic quantities characterizing the radiation field
Hardcopy , PDF
17-11-2022
English
18-10-2004
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Calibration and traceability of reference radiation
fields
5 General principles for calibrations of radionuclide
beta-particle fields
5.1 General
5.2 Scaling to derive equivalent thicknesses of various
materials
5.3 Characterization of the radiation field in terms of
penetrability
6 Calibration procedures using the extrapolation chamber
6.1 General
6.2 Determination of the reference beta-particle
absorbed-dose rate
7 Calibrations with other measurement devices
7.1 Calibrations with thermoluminescence dosemeters
7.2 Calibrations with thermally stimulated exo-electron
emission dosemeters
7.3 Calibrations with ionization chambers
7.4 Calibrations with scintillator detectors
8 Measurements at non-perpendicular incidence
9 Uncertainties
Annex A (informative) List of symbols
Annex B (normative) Extrapolation chamber measurements
Annex C (normative) Extrapolation chamber measurement
correction factors
Annex D (informative) Example of an uncertainty analysis
Bibliography
Provides methods for the measurement of the directional absorbed-dose rate in a tissue-equivalent slab phantom in the ISO 6980 reference beta-particle radiation fields.
Committee |
NCE/2
|
DevelopmentNote |
Supersedes 99/715925 DC. (12/2004) Together with BS ISO 6980-1 and BS ISO 6980-3, supersedes BS ISO 6980. (10/2006) Reviewed and confirmed by BSI, March 2014. (02/2014)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This part of ISO6980 specifies methods for the measurement of the directional absorbed-dose rate in a tissue-equivalent slab phantom in the ISO6980 reference beta-particle radiation fields. The energy range of the beta-particle-emitting isotopes covered by these reference radiations is 0,066 to 3,54 MeV (maximum energy). Radiation energies outside this range are beyond the scope of this standard. While measurements in a reference geometry (depth of 0,07mm at perpendicular incidence in a tissue-equivalent slab phantom) with a reference class extrapolation chamber are dealt with in detail, the use of other measurement systems and measurements in other geometries are also described, although in less detail. The ambient dose equivalent, H*(10) as used for area monitoring of strongly penetrating radiation, is not an appropriate quantity for any beta radiation, even for that penetrating a 10mm thick layer of ICRU tissue (i.e. Emax>2 MeV). If adequate protection is provided at 0,07mm, only rarely will one be concerned with other depths, for example3mm.
This document is geared towards organizations wishing to establish reference-class dosimetry capabilities for beta particles, and serves as a guide to the performance of dosimetry with the reference class extrapolation chamber for beta-particle dosimetry in other fields. Guidance is also provided on the statement of measurement uncertainties.
Standards | Relationship |
ISO 6980-2:2004 | Identical |
ISO 6980:1996 | Reference beta radiations for calibrating dosemeters and dose-rate meters and for determining their response as a function of beta-radiation energy |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.