• BS ISO 7240-8:2014

    Current The latest, up-to-date edition.

    Fire detection and alarm systems Point-type fire detectors using a carbon monoxide sensor in combination with a heat sensor

    Available format(s):  Hardcopy, PDF

    Language(s):  English

    Published date:  31-01-2015

    Publisher:  British Standards Institution

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions and abbreviated terms
    4 Requirements
    5 Tests
    6 Test report
    7 Marking
    8 Data
    Annex A (normative) - Gas test chamber for CO
            response value and cross sensitivity measurements
    Annex B (normative) - Heat tunnel for response time and
            response temperature measurements
    Annex C (normative) - Apparatus for impact test
    Annex D (normative) - Fire test room
    Annex E (normative) - Smouldering (pyrolysis) wood fire (TF2)
    Annex F (normative) - Glowing smouldering cotton fire (TF3)
    Annex G (normative) - Open plastics (polyurethane) fire (TF4)
    Annex H (normative) - Liquid (n-heptane) fire (TF5)
    Annex I (informative) - Information concerning the construction
            of the gas test chamber
    Annex J (informative) - Construction of the heat tunnel

    Abstract - (Show below) - (Hide below)

    Describes requirements, test methods, and performance criteria for point multi-sensor fire detectors that incorporate at least one carbon monoxide (CO) sensor in combination with one or more heat sensors, for use in fire detection and alarm systems installed in buildings.

    Scope - (Show below) - (Hide below)

    This part of ISO7240 specifies requirements, test methods, and performance criteria for point multi-sensor fire detectors that incorporate at least one carbon monoxide (CO) sensor in combination with one or more heat sensors, for use in fire detection and alarm systems installed in buildings (see ISO7240-1).

    For the testing of other types of CO multi-sensor fire detectors, or CO and heat multi-sensor fire detectors working on different principles, this part of ISO7240 is only to be used for guidance. CO and heat multi-sensor fire detectors with special characteristics and developed for specific risks are not covered by this part of ISO7240.

    General Product Information - (Show below) - (Hide below)

    Committee FSH/12/2
    Development Note Supersedes 05/30141222 DC. (11/2007)
    Document Type Standard
    Publisher British Standards Institution
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    BS 5839-6:2013 Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises
    BS 5839-1(2002) : 2002 FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
    BS 5839-1:2017 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
    12/30260278 DC : 0 BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE
    BS 5839-1:2013 Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises
    07/30171700 DC : DRAFT OCT 2007 BS 5839-1 AMD1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR SYSTEM DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
    IEC 62599-2:2010 Alarm systems - Part 2: Electromagnetic compatibility - Immunity requirements for components of fire and security alarm systems
    IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
    IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
    ISO 7240-5:2012 Fire detection and alarm systems Part 5: Point-type heat detectors
    IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
    ISO 7240-1:2014 Fire detection and alarm systems — Part 1: General and definitions
    IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective