BS ISO 7507-3:2006
Current
The latest, up-to-date edition.
Petroleum and liquid petroleum products. Calibration of vertical cylindrical tanks Optical-triangulation method
Hardcopy , PDF
English
31-01-2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Precautions
5 Equipment
5.1 Equipment for measurement of angles
5.2 Stadia
6 Equipment set-up and procedure
6.1 Preparation of tank
6.2 Establishment of calibration conditions
6.3 Set-up of theodolites and/or total stations
7 Stadia set-up and procedure
8 Measurement of horizontal distance between two theodolite
stations using a stadia
9 Measurement of horizontal distance between two theodolite
stations using a total station
10 Procedure for internal optical tank wall measurements
11 Procedures for external measurements
11.1 General
11.2 Reference circumference measured by strapping
11.3 Reference distances measured between pairs of
theodolite stations
12 Tolerances
12.1 Distances between theodolites
12.2 Horizontal angles
12.3 Reference circumference
13 Other measurements for tank calibrations
13.1 Tank-bottom calibrations
13.2 Other measurements and data
14 Calculations and development of tank capacity tables
14.1 From the internal procedure
14.2 From the reference circumference procedure
14.3 From the reference distances between pairs of
theodolites
14.4 Corrections
14.5 Tank capacity table
Annex A (normative) Computation of internal radii from
internal measurements
Annex B (normative) Determination of the radius of the
circle by the least-squares method
Annex C (normative) Computation of internal radii from
reference circumference and external
measurements
Annex D (normative) Computation of internal radii from
reference distances between pairs of
theodolite stations
Annex E (informative) Calibration uncertainties
Annex F (normative) Procedure for checking the theodolite(s)
Bibliography
Defines a calibration procedure for application to tanks above 8 m in diameter with cylindrical courses that are substantially vertical. It provides a method for determining the volumetric quantity contained within a tank at gauged liquid levels.
Committee |
PTI/12
|
DevelopmentNote |
Supersedes BS 7723-3(1994) and 05/30060740 DC. (01/2007)
|
DocumentType |
Standard
|
Pages |
48
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This part of ISO7507 specifies a calibration procedure for application to tanks above 8m in diameter with cylindrical courses that are substantially vertical. It provides a method for determining the volumetric quantity contained within a tank at gauged liquid levels. The measurements required to determine the radius are made either internally (Clause10) or externally (Clause11). The external method is applicable only to tanks that are free of insulation.
This method is suitable for tanks tilted up to a 3%deviation from the vertical provided that a correction is applied for the measured tilt as described in ISO7507-1.
Standards | Relationship |
ISO 7507-3:2006 | Identical |
ISO 7507-2:2005 | Petroleum and liquid petroleum products Calibration of vertical cylindrical tanks Part 2: Optical-reference-line method |
ISO 7507-1:2003 | Petroleum and liquid petroleum products Calibration of vertical cylindrical tanks Part 1: Strapping method |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.