1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Conformance tests for ISO/IEC 18000-4 - 2,45 GHz
  5.1 Default items applicable to the test methods
      5.1.1 Test environment
      5.1.2 Pre-conditioning
      5.1.3 Default tolerance
      5.1.4 Total measurement uncertainty
  5.2 Conformance tests for ISO/IEC 18000-4 Mode 2
      5.2.1 Test set-up and measurement equipment
            for Mode 2
            5.2.1.1 Test set-up for interrogator testing
            5.2.1.2 Test set-up for tag testing
            5.2.1.3 Test equipment
      5.2.2 Functional test - interrogator
            5.2.2.1 Modulation
            5.2.2.2 Operating frequency accuracy
      5.2.3 Functional test - tag
            5.2.3.1 Modulation
            5.2.3.2 Coding
            5.2.3.3 Sub-carrier frequency

Defines test methods for determining the conformance of radio frequency identification (RFID) devices (tags and interrogators) for item management with the specifications given in the corresponding part of ISO/IEC 18000, but does not apply to the testing of conformity with regulatory or similar requirements.

Committee
IST/34
DocumentType
Standard
Pages
20
PublisherName
British Standards Institution
Status
Current

This part of ISO/IECTR18047 defines test methods for determining the conformance of radio frequency identification devices (tags and interrogators) for item management with the specifications given in the corresponding part of ISO/IEC18000, but does not apply to the testing of conformity with regulatory or similar requirements.

The test methods require only that the mandatory functions, and any optional functions which are implemented, be verified. This may, in appropriate circumstances, be supplemented by further, application specific functionality criteria that are not available in the general case.

The interrogator and tag conformance parameters in this part of ISO/IECTR18047 are:

  • mode-specific conformance parameters including nominal values and tolerances;

  • parameters that apply directly affecting system functionality and inter-operability.

The following are not included in this part of ISO/IECTR18047:

  • parameters that are already included in regulatory test requirements;

  • high-level data encoding conformance test parameters (these are specified in ISO/IEC15962).

Unless otherwise specified, the tests in this part of ISO/IECTR18047 apply exclusively to RFID tags and interrogator defined in ISO/IEC18000-4 Mode 2.

Standards Relationship
ISO/IEC TR 18047-4:2004 Identical

ISO/IEC 18000-4:2015 Information technology Radio frequency identification for item management Part 4: Parameters for air interface communications at 2,45 GHz
ISO/IEC 18000-1:2008 Information technology Radio frequency identification for item management Part 1: Reference architecture and definition of parameters to be standardized

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.