• There are no items in your cart

C22.2 NO. 29-15 (R2019)

Current

Current

The latest, up-to-date edition.

Panelboards and enclosed panelboards

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2015

Preface This is the sixth edition of C22.2 No. 29, Panelboards and enclosed panelboards , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2011, 1989, 1983, 1955, and 1936. In addition to incorporating minor edits and corrections to the previous edition, this new edition includes the requirements for: a) determining the accessibility of live parts by use of a finger probe; b) the integration of transfer switch equipment within a panelboard; c) clarification of neutral assembly requirements; and d) clarification of ampacity termination temperature markings. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to panelboards and enclosed panelboards, rated 600 V and less, for use in nonhazardous locations in accordance with the Canadian Electrical Code, Part I, to provide overcurrent protection for a number of circuits. 1.2 Clauses 1 to 6 apply to panelboards and enclosed panelboards of other than the service entrance type and apply, unless otherwise noted, to the panelboards covered by Clauses 8 and 9 as follows: a) Clause 8 - panelboards for service entrance use; and b) Clause 9 - custom-built panelboard assemblies. 1.3 This Standard covers the construction of the synthetic fuses to be used in the simulated load cycle test on fusible panelboards. (See Clause 10.) 1.4 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

Preface This is the sixth edition of C22.2 No. 29, Panelboards and enclosed panelboards , one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. It supersedes the previous editions published in 2011, 1989, 1983, 1955, and 1936. In addition to incorporating minor edits and corrections to the previous edition, this new edition includes the requirements for: a) determining the accessibility of live parts by use of a finger probe; b) the integration of transfer switch equipment within a panelboard; c) clarification of neutral assembly requirements; and d) clarification of ampacity termination temperature markings. For general information on the Standards of the Canadian Electrical Code, Part II, see the Preface of CAN/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to panelboards and enclosed panelboards, rated 600 V and less, for use in nonhazardous locations in accordance with the Canadian Electrical Code, Part I, to provide overcurrent protection for a number of circuits. 1.2 Clauses 1 to 6 apply to panelboards and enclosed panelboards of other than the service entrance type and apply, unless otherwise noted, to the panelboards covered by Clauses 8 and 9 as follows: a) Clause 8 - panelboards for service entrance use; and b) Clause 9 - custom-built panelboard assemblies. 1.3 This Standard covers the construction of the synthetic fuses to be used in the simulated load cycle test on fusible panelboards. (See Clause 10.) 1.4 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

DocumentType
Standard
ISBN
978-1-77139-712-4
Pages
84
ProductNote
This standard also refers to CAN/CSA-C22.2 No. 0-M91(R2010), C22.2 No. 0.12-M1985 (R2012) , C22.2 No. 39-M1987 (R2013), C22.2 No. 59.1-M1987, C22.2 No. 65-1956 (R2013), C22.2 No. 178.2-04 (R2009) , C22.2 No. 197-M1983 (R2013) , CAN/CSA-C22.2 No. 198.1-06 (R2010) ,
PublisherName
Canadian Standards Association
Status
Current
Supersedes

View more information
€227.74
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.