CAN/CSA-C22.2 NO. 61010-2-020:17
Current
The latest, up-to-date edition.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges (Adopted IEC 61010-2-020:2016, third edition, 2016-05) | Exigences de scurit pour appareils lectriques de mesurage, de rgulation et de laboratoire - Partie 2-020: Exigences particulires pour centrifugeuses de laboratoire (norme IEC 61010-2-020:2016 adopte, troisime dition, 2016-05)
PDF , Hardcopy
English - French, English
01-01-2017
FOREWORD
1 Scope and object
2 Normative references
3 Terms and definitions
4 Tests
5 Marking and documentation
6 Protection against electric shock
7 Protection against mechanical HAZARDS
8 Mechanical resistance to shock and impact
9 Protection against the spread of fire
10 Equipment temperature limits and resistance to heat
11 Protection against HAZARDS from fluids
12 Protection against radiation, including laser sources, and
against sonic and ultrasonic pressure
13 Protection against liberated gases and substances, explosion
and implosion
14 Components
15 Protection by interlocks
16 Hazards resulting from application
17 Risk assessment
Annexes
Annex L - Index of defined terms
Annex AA (normative) - Dynamic microbiological test
method for BIOSEALS
Annex BB (informative) - General guidance and rationale for
particular subclauses
Annex CC (informative) - General guidance for an empirical
method to determine the kinetic energy of a ROTOR
Bibliography
Pertains to electrically powered LABORATORY CENTRIFUGES.
DevelopmentNote |
Supersedes CSA C22.2.1010.2.020. (09/2009)
|
DocumentType |
Standard
|
ISBN |
978-1-4883-0946-5
|
Pages |
0
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
Preface This is the third edition of CAN/CSA-C22.2 No. 61010-2-020, Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-020: Particular requirements for laboratory centrifuges, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-020 (third edition, 2016-05). It supersedes the previous edition published in 2009 as CAN/CSA-C22.2 No. 61010-2-020 (adopted IEC 61010-2-020:2006). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as \"CAN/CSA-C22.2 No. 61010-2-020\" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian deviations). Scope This clause of Part 1 is applicable except as follows: 1.1.1 Scope Replacement: This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES. This group safety publication is primarily intended to be used as a product safety standard for the products mentioned in the scope, but shall also be used by technical committees in the preparation of its publications for products similar to those mentioned in the scope of this standard, in accordance with the principles laid down in IEC Guide 104 and lSO/lEC Guide 51. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard, it will also need to meet the requirements of those other Part 2 standards. 1.1.2 Equipment excluded from scope Addition: Add the following new item: aa) IEC 60034 (Rotating electrical machinery); ------------------------------------------------------------------------------------------------------------ Prface CSA Ce document constitue la troisime dition de la CAN/CSA-C22.2 n 61010-2-020, Exigences de scurit pour appareils lectriques de mesurage, de rgulation et de laboratoire - Partie 2-020 : Exigences particulires pour centrifugeuses de laboratoire. Il s\'agit de l\'adoption, avec exigences propres au Canada, de la norme IEC (Commission lectrotechnique Internationale) 61010-2-020 (troisime dition, 2016-05) qui porte le mme titre. Il remplace l\'dition antrieure, publie en 2009 qui portait la dsignation CAN/CSA-C22.2 n 61010-2-020 (norme IEC 61010-2-020:2006 adopte). Il fait partie d\'une srie de normes publies par le Groupe CSA qui constituent le Code canadien de l\'lectricit, Deuxime partie. Par souci de brivet, tout au long de ce document, il sera appel CAN/CSA-C22.2 n 61010-2-020. Cette norme est conue pour tre utilise de concert avec la CAN/CSA-C22.2 n 61010-1:12, Rgles de scurit pour appareils lectriques de mesurage, de rgulation et de laboratoire - Partie 1 : Exigences gnrales (norme IEC 61010-1:2010 adopte, avec exigences propres au Canada). Cette norme est juge convenable l\'valuation de la conformit selon le domaine d\'application tabli dans la norme. Domaine d\'application L\'article de la Partie 1 s\'applique avec les exceptions suivantes: 1.1.1 Domaine d\'application Remplacement: La prsente Partie 2 s\'applique aux CENTRIFUGEUSES DE LABORATOIRE alimentes en nergie lectrique. Cette publication groupe de scurit est principalement destine tre utilise comme une norme de scurit de produit pour les produits mentionns dans le domaine d\'application. Elle doit galement tre utilise par les comits d\'tudes pour l\'laboration de leurs publications relatives des produits semblables ceux mentionns dans le domaine d\'application de la prsente norme, conformment aux principes tablis dans le Guide IEC 104 et le Guide lSO/lEC 51. NOTE Si une ou toutes les parties de l\'appareil relvent du domaine d\'application d\'une ou plusieurs autres Parties 2 de l\'IEC 61010, ainsi que du domaine d\'application de la prsente Norme, il est galement ncessaire que l\'appareil satisfasse l\'ensemble des exigences de ces parties 2. 1.1.2 Appareils exclus du domaine d\'application Addition: Ajouter le nouveau point suivant: aa) IEC 60034 (Machines lectriques tournantes).
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.