• Shopping Cart
    There are no items in your cart

CAN/CSA-ISO 11138-4:17 (R2022)

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Sterilization of health care products - Biological indicators - Part 4: Biological indicators for dry heat sterilization (Adopted ISO 11138-4:2017, second edition, 2017-03)

Available format(s)

PDF

Language(s)

French, English

Published date

01-01-2017

Superseded date

16-05-2025

€54.50
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Test organism
6 Suspension
7 Carrier and primary packaging
8 Inoculated carriers and biological indicators
9 Population and resistance
Annex A (normative) - Method for determination of
        resistance to dry heat sterilization
Annex B (normative) - Calculation of z value
Bibliography

Defines requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilization processes employing dry heat as the sterilizing agent at sterilizing temperatures within the range of 120 degrees C to 180 degrees C.

DocumentType
Standard
ISBN
978-1-4883-1190-1
Pages
0
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy

CSA Preface This is the first edition of CAN/CSA-ISO 11138-4, Sterilization of health care products — Biological indicators — Part 4: Biological indicators for dry heat sterilization processes, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 11138-4 (second edition, 2017-03). For brevity, this Standard will be referred to as “CAN/CSA-ISO 11138-4” throughout. This Standard was reviewed for Canadian adoption by the SCC Mirror Committee to ISO/TC 198, under the jurisdiction of the CSA Technical Committee on Medical Device Reprocessing and the CSA Strategic Steering Committee on Health Care Technology & Systems, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This document specifies requirements for test organisms, suspensions, inoculated carriers, biological indicators and test methods intended for use in assessing the performance of sterilization processes employing dry heat as the sterilizing agent at sterilizing temperatures within the range of 120 °C to 180 °C. NOTE 1 Requirements for validation and control of dry heat sterilization processes are provided by ISO 20857. NOTE 2 Requirements for work place safety can be provided by national or regional regulations.

Standards Relationship
ISO 11138-4:2017 Identical

ISO 18472:2006 Sterilization of health care products — Biological and chemical indicators — Test equipment
ISO 20857:2010 Sterilization of health care products — Dry heat — Requirements for the development, validation and routine control of a sterilization process for medical devices
ISO 11138-1:2017 Sterilization of health care products — Biological indicators — Part 1: General requirements
ISO 14161:2009 Sterilization of health care products — Biological indicators — Guidance for the selection, use and interpretation of results

€54.50
Excluding VAT