CAN/CSA-ISO 11140-3:18 (R2023)
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test (Adopted ISO 11140-3:2007, second edition, 2007-03-15, including technical corrigendum 1:2007)
French, English
01-01-2018
20-05-2025
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Indicator system format
6 Performance requirements
7 Packaging and labeling
8 Quality assurance
Annex A (normative) - Determination of
strength after steam sterilization
Annex B (normative) - Estimation of visual
difference between colour of
the substrate and the changed
(or unchanged) indicator system
by determination of relative
reflectance density
Annex C (normative) - Determination of
indicator colour change on
exposure to dry saturated
steam
Annex D (normative) - Determination of
indicator colour change on
exposure to dry heat
Annex E (normative) - Accelerated ageing
of test samples
Annex F (normative) - Determination of
transfer of indicator to
standard test pack on
processing
Annex G (normative) - Determination of
shelf life of the product
Annex H (normative) - Steam exposure apparatus
Annex I (normative) - Determination of sensitivity
of the indicator to the
presence of air
Annex J (normative) - Air injection system
Annex K (normative) - Standard test pack
Bibliography
CSA Preface This is the first edition of CAN/CSA-ISO 11140-3, Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 11140-3 (second edition, 2007-03-15), including Technical Corrigendum 1:2007. Scope This part of ISO 11140 specifies the requirements for chemical indicators to be used in the steam penetration test for steam sterilizers for wrapped goods, e.g. instruments and porous materials. The indicator for this purpose is a Class 2 indicator as described in ISO 11140-1. Indicators complying with this part of ISO 11140 are intended for use in combination with the standard test pack as described in EN 285. This part of ISO 11140 does not consider the performance of the standard test pack, but does specify the performance of the indicator systems.
| DocumentType |
Standard
|
| ISBN |
978-1-4883-1666-1
|
| Pages |
42
|
| PublisherName |
Canadian Standards Association
|
| Status |
Superseded
|
| SupersededBy |
CSA Preface This is the first edition of CAN/CSA-ISO 11140-3, Sterilization of health care products — Chemical indicators — Part 3: Class 2 indicator systems for use in the Bowie and Dick-type steam penetration test, which is an adoption without modification of the identically titled ISO (International Organization for Standardization) Standard 11140-3 (second edition, 2007-03-15), including Technical Corrigendum 1:2007. For brevity, this Standard will be referred to as “CAN/CSA-ISO 11140-3” throughout. This Standard was reviewed for Canadian adoption by the SCC Mirror Committee to ISO/TC 198, under the jurisdiction of the CSA Technical Committee on Medical Device Reprocessing and the CSA Strategic Steering Committee on Health Care Technology & Systems, and has been formally approved by the Technical Committee. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This part of ISO 11140 specifies the requirements for chemical indicators to be used in the steam penetration test for steam sterilizers for wrapped goods, e.g. instruments and porous materials. The indicator for this purpose is a Class 2 indicator as described in ISO 11140-1. Indicators complying with this part of ISO 11140 are intended for use in combination with the standard test pack as described in EN 285. This part of ISO 11140 does not consider the performance of the standard test pack, but does specify the performance of the indicator systems.
| Standards | Relationship |
| ISO 11140-3:2007 | Identical |
| ISO 5636-3:2013 | Paper and board — Determination of air permeance (medium range) — Part 3: Bendtsen method |
| EN 285:2015 | Sterilization - Steam sterilizers - Large sterilizers |
| ISO 187:1990 | Paper, board and pulps — Standard atmosphere for conditioning and testing and procedure for monitoring the atmosphere and conditioning of samples |
| ISO 11140-1:2014 | Sterilization of health care products — Chemical indicators — Part 1: General requirements |
| ISO 5-4:2009 | Photography and graphic technology — Density measurements — Part 4: Geometric conditions for reflection density |
| ISO 5457:1999 | Technical product documentation — Sizes and layout of drawing sheets |
| ISO 5-3:2009 | Photography and graphic technology — Density measurements — Part 3: Spectral conditions |
| ISO 5-1:2009 | Photography and graphic technology — Density measurements — Part 1: Geometry and functional notation |
| ISO/CIE 10526:1999 | CIE standard illuminants for colorimetry |
| ISO 2248:1985 | Packaging — Complete, filled transport packages — Vertical impact test by dropping |