CEI EN 55011 : 2017
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
INDUSTRIAL, SCIENTIFIC AND MEDICAL EQUIPMENT - RADIO-FREQUENCY DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT
Hardcopy , PDF
English - Italian
01-01-2017
28-07-2025
European foreword
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Frequencies designated for ISM use
5 Classification of equipment
6 Limits of electromagnetic disturbances
7 Measurement requirements
8 Special provisions for test site measurements (9 kHz to
1 GHz)
9 Radiation measurements: 1 GHz to 18 GHz
10 Measurement in situ
11 Safety precautions for emission measurements on ISM RF
equipment
12 Measurement uncertainty
Annex A (informative) - Examples of equipment classification
Annex B (informative) - Precautions to be taken in the use of a
spectrum analyzer
Annex C (normative) - Measurement of electromagnetic radiation
disturbance in the presence of signals from radio
transmitters
Annex D (informative) - Propagation of interference from
industrial radio-frequency equipment at frequencies
between 30 MHz and 300 MHz
Annex E (informative) - Recommendations of CISPR for
protection of certain radio services in particular
areas
Annex F (informative) - Frequency bands allocated for
safety-related radio services
Annex G (informative) - Frequency bands allocated for
sensitive radio services
Annex H (informative) - Statistical assessment of series
produced equipment against the requirements
of CISPR standards
Annex I (normative) - Artificial Network (AN) for the
assessment of disturbance voltages at d.c. power
ports of semiconductor power converters
Annex J (informative) - Measurements on Grid Connected
Power Converters (GCPC) - Setups for an effective
test site configuration
Annex K (informative) - Test site configuration and
instrumentation - Guidance on prevention of
saturation effects in mitigation filters of
transformer-less power converters during
type tests according to this standard
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZB (normative) - Frequencies designated on a national
basis in CENELEC countries for use as fundamental
ISM frequencies
Annex ZZ (informative) - Coverage of Essential Requirements
of EU Directives
Bibliography
Pertains to industrial, scientific and medical electrical equipment operating in the frequency range 0 Hz to 400 GHz and to domestic and similar appliances designed to generate and/or use locally radio-frequency energy.
| Committee |
CT 210
|
| DevelopmentNote |
Classificazione CEI 110-6 (08/2001) 5ED 2013 Edition is valid until 15-02-2019. (02/2017)
|
| DocumentType |
Standard
|
| Pages |
102
|
| ProductNote |
New child AMD 1 2017 is now added
|
| PublisherName |
Comitato Elettrotecnico Italiano
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| EN 55011:2016/A1:2017 | Identical |
| CEI 64-8/5 : 2012 | LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 5: ERECTION AND SELECTION OF ELECTRICAL EQUIPMENT |
| CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
| EN 62135-2:2015 | Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
| CISPR 16-4-2:2011+AMD1:2014 CSV | Specification for radio disturbance and immunity measuring apparatusand methods - Part 4-2: Uncertainties, statistics and limit modelling - Measurement instrumentation uncertainty |
| EN 55016-2-3:2017 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
| EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
| CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
| IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
| CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
| IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
| CISPR 16-2-1:2014 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements |
| IEC 61922:2002 | High-frequency induction heating installations - Test methods for the determination of power output of the generator |
| CISPR 15:2013+AMD1:2015 CSV | Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment |
| IEC 60974-10:2014+AMD1:2015 CSV | Arc welding equipment - Part 10: Electromagnetic compatibility (EMC)requirements |
| IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
| IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
| EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
| IEC 60601-2-2:2017 | Medical electrical equipment - Part 2-2: Particular requirements for the basic safety and essential performance of high frequency surgical equipment and high frequency surgical accessories |
| IEC 61308:2005 | High-frequency dielectric heating installations - Test methods for the determination of power output |
| EN 61307:2011 | Industrial microwave heating installations - Test methods for the determination of power output |
| IEC 62135-2:2015 | Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements |
| CISPR 16-2-3:2016 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements |
| EN 60974-10:2014/A1:2015 | ARC WELDING EQUIPMENT - PART 10: ELECTROMAGNETIC COMPATIBILITY (EMC) REQUIREMENTS (IEC 60974-10:2014/A1:2015) |
| CEI 62-11 : 1ED 1983 | APPARECCHI ELETTROMEDICALI. NORME PARTICOLARI DI SICUREZZA PER GLI APPARECCHI DI ELETTROCHIRURGIA AD ALTA FREQUENZA |
| IEC 61307:2011 | Industrial microwave heating installations - Test methods for the determination of power output |
| EN 55016-2-1:2014/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 2-1: METHODS OF MEASUREMENT OF DISTURBANCES AND IMMUNITY - CONDUCTED DISTURBANCE MEASUREMENTS (CISPR 16-2-1:2014/A1:2017) |
| IEC 60705:2010+AMD1:2014 CSV | Household microwave ovens - Methods for measuring performance |
| EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.