• CEI EN 60601-2-24 : 2016

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MEDICAL ELECTRICAL EQUIPMENT - PART 2-24: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF INFUSION PUMPS AND CONTROLLERS

    Available format(s):  Hardcopy, PDF

    Superseded date:  24-01-2019

    Language(s):  English

    Published date:  01-01-2016

    Publisher:  Comitato Elettrotecnico Italiano

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    201.1 Scope, object and related standards
    201.2 Normative references
    201.3 Terms and definitions
    201.4 General requirements
    201.5 General requirements for testing of ME EQUIPMENT
    201.6 Classification of ME EQUIPMENT and ME SYSTEMS
    201.7 ME EQUIPMENT identification, marking and documents
    201.8 Protection against electrical HAZARDS from ME
           EQUIPMENT
    201.9 Protection against MECHANICAL HAZARDS of ME
           EQUIPMENT and ME SYSTEMS
    201.10 Protection against unwanted and excessive radiation
           HAZARDS
    201.11 Protection against excessive temperatures and other
           HAZARDS
    201.12 Accuracy of controls and instruments and protection
           against hazardous outputs
    201.13 HAZARDOUS SITUATIONS and fault conditions
    201.14 PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)
    201.15 Construction of ME EQUIPMENT
    201.16 ME SYSTEMS
    201.17 Electromagnetic compatibility of ME EQUIPMENT
           and ME SYSTEMS
    202 Electromagnetic compatibility - Requirements and tests
    206 Usability
    208 General requirements, tests and guidance for alarm
           systems in medical electrical equipment and medical
           electrical systems
    Annexes
    Annex AA (informative) - Particular guidance and rationale
    Bibliography
    Index of defined terms used in this particular standard
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications
    Annex ZZ (informative) - Coverage of Essential Requirements
             of EU Directives

    Abstract - (Show below) - (Hide below)

    Pertains to the BASIC SAFETY and ESSENTIAL PERFORMANCE of INFUSION PUMPS and VOLUMETRIC INFUSION CONTROLLERS, hereafter referred to as ME EQUIPMENT.

    General Product Information - (Show below) - (Hide below)

    Committee CT 62
    Development Note Classificazione CEI 62-99 (08/2001) Supersedes CEI 62-16 (03/2004) 1ED 1999 Edition is valid until 14-04-2018. (02/2016) Italian translation of 2ED 2016 Issued on 01/02/2018. (03/2018)
    Document Type Standard
    Publisher Comitato Elettrotecnico Italiano
    Status Superseded
    Superseded By
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
    EN ISO 8536-4:2013/A1:2013 INFUSION EQUIPMENT FOR MEDICAL USE - PART 4: INFUSION SETS FOR SINGLE USE, GRAVITY FEED (ISO 8536-4:2010/AMD 1:2013)
    IEC 60601-1-6:2010+AMD1:2013 CSV Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability
    EN 60601-1-6:2010/A1:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-6: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: USABILITY (IEC 60601-1-6:2010/A1:2013)
    IEC 60601-1-8:2006+AMD1:2012 CSV Medical electrical equipment - Part 1-8: General requirements forbasic safety and essential performance - Collateral Standard: General requirements, tests and guidance for alarm systems inmedical electrical equipment and medical electrical systems
    EN ISO 7864:2016 Sterile hypodermic needles for single use - Requirements and test methods (ISO 7864:2016)
    IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
    ISO 7864:2016 Sterile hypodermic needles for single use — Requirements and test methods
    ISO 8536-4:2010 Infusion equipment for medical use Part 4: Infusion sets for single use, gravity feed
    ISO 3696:1987 Water for analytical laboratory use — Specification and test methods
    EN ISO 3696:1995 Water for analytical laboratory use - Specification and test methods (ISO 3696:1987)
    EN 60601-1-8:2007/A11:2017 MEDICAL ELECTRICAL EQUIPMENT - PART 1-8: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: GENERAL REQUIREMENTS, TESTS AND GUIDANCE FOR ALARM SYSTEMS IN MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS (IEC 60601-1-8:2006/A1:2012)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective