• CEI EN 60660 : 2000

    Current The latest, up-to-date edition.

    INSULATORS TESTS ON INDOOR POST INSULATORS OF ORGANIC MATERIAL FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1 KV UP TO BUT NOT INCLUDING 300 KV

    Available format(s):  Hardcopy, PDF

    Language(s):  English - Italian

    Published date:  01-01-2000

    Publisher:  Comitato Elettrotecnico Italiano

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1. General
    2. General requirements for tests
    3. Type tests
    4. Sample tests
    5. Tests
    Annex A (Informative) - Tolerances of form and position
    ANNEX ZA (normative) - Normative references to international
                           publications with their corresponding
                           european publications

    Abstract - (Show below) - (Hide below)

    Describes the post insulators of organic material for indoor service in electrical installations or equipment operating in air at atmospheric pressure on alternating current with a nominal voltage greater than 1000 V up to, but not including, 300 kV, as defined by range I of IEC 60071-1, and a frequency not greater than 100 Hz.

    General Product Information - (Show below) - (Hide below)

    Committee CT 36
    Development Note Classificazione CEI 36-26. (08/2001) Supersedes CEI 36. (05/2008)
    Document Type Standard
    Publisher Comitato Elettrotecnico Italiano
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    CEI 28-3 : 2ED 1986 COORDINAMENTO DELL'ISOLAMENTO PER TENSIONI SUPERIORI A 1 KV
    IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
    CEI 42-3 : 2ED 1997
    IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
    HD 588.1 : S1 AMD 1 HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS
    CEI 15-29 : 1ED 1997 METODI DI PROVA PER LA VALUTAZIONE DELLA RESISTENZA A TRACCIAMENTO ED EROSIONE DI MATERIALI ISOLANTI ELETTRICI IMPIEGATI IN CONDIZIONI AMBIENTALI SEVERE
    EN ISO 9000-1 : 1994 QUALITY MANAGEMENT AND QUALITY ASSURANCE STANDARDS - PART 1: GUIDELINES FOR SELECTION AND USE (ISO 9000-1:1994)
    ISO 9000-2:1997 Quality management and quality assurance standards — Part 2: Generic guidelines for the application of ISO 9001, ISO 9002 and ISO 9003
    IEC 60273:1990 Characteristic of indoor and outdoor post insulators for systems with nominal voltages greater than 1000 V
    IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
    EN 60071-1:2006/A1:2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
    CEI 36-12 : 1998 CHARACTERISTICS OF INDOOR AND OUTDOOR POST INSULATORS FOR SYSTEMS WITH NOMINAL VOLTAGES GREATER THAN 1000 V
    HD 380 : 200S2 TEST METHODS FOR EVALUATING RESISTANCE TO TRACKING AND EROSION OF ELECTRICAL INSULATING MATERIALS USED UNDER SEVERE AMBIENT CONDITIONS
    IEC 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
    IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
    IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
    ISO 9000-1:1994 Quality management and quality assurance standards — Part 1: Guidelines for selection and use
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective