CEI EN 60953-1 : 1996
Current
The latest, up-to-date edition.
RULES FOR STEAM TURBINE THERMAL ACCEPTANCE TESTS - PART 1: METHOD A - HIGH ACCURACY FOR LARGE CONDENSING STEAM TURBINES
Hardcopy , PDF
English - Italian
01-01-1996
FOREWORD
INTRODUCTION
1 SCOPE AND OBJECT
2 UNITS, SYMBOLS, TERMS AND DEFINITIONS
3 GUIDING PRINCIPLES
4 MEASURING TECHNIQUES AND MEASURING
INSTRUMENTS
5 EVALUATION OF TESTS
6 CORRECTION OF TEST RESULTS AND COMPARISON
WITH GUARANTEE
Annex A (informative) - FEEDWATER HEATER LEAKAGE
AND CONDENSER LEAKAGE TESTS
Annex B (normative) - THROAT TAP NOZZLE
Annex C (normative) - THE USE OF FLOW STRAIGHTENERS
IN FLUID FLOW MEASUREMENTS
Annex ZA (normative) - Normative references to
International Publications with their
corresponding European Publications
Related to thermal acceptance tests with high accuracy for condensing steam turbines driving generators for electric power services.
| Committee |
CT 4/5
|
| DevelopmentNote |
Classificazione CEI 5-3/1 (09/2001)
|
| DocumentType |
Standard
|
| Pages |
116
|
| PublisherName |
Comitato Elettrotecnico Italiano
|
| Status |
Current
|
| Standards | Relationship |
| IEC 60953-1:1990 | Identical |
| EN 60953-1:1995 | Identical |