• CEI EN 61347-2-3 : 2012

    Current The latest, up-to-date edition.

    LAMP CONTROLGEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS

    Available format(s):  Hardcopy, PDF

    Language(s):  English - Italian

    Published date:  01-01-2012

    Publisher:  Comitato Elettrotecnico Italiano

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 General requirements
    5 General notes on tests
    6 Classification
    7 Marking
    8 Protection against accidental contact with live parts
    9 Terminals
    10 Provisions for protective earthing
    11 Moisture resistance and insulation
    12 Electric strength
    13 Thermal endurance test for windings
    14 Fault conditions
    15 Protection of associated components
    16 Abnormal conditions
    17 Behaviour of the controlgear at end of lamp life
    18 Construction
    19 Creepage distances and clearances
    20 Screws, current-carrying parts and connections
    21 Resistance to heat, fire and tracking
    22 Resistance to corrosion
    Annex A (normative) - Test to establish whether a conductive
            part is a live part which may cause an electric shock
    Annex B (normative) - Particular requirements for
            thermally protected lamp controlgear
    Annex C (normative) - Particular requirements for electronic
            lamp controlgear with means of protection against
            overheating
    Annex D (normative) - Requirements for carrying out the
            heating tests of thermally protected lamp controlgear
    Annex E (normative) - Use of constant S other than
            4500 in t[w] tests
    Annex F (normative) - Draught-proof enclosure
    Annex G (normative) - Explanation of the derivation of the
            values of pulse voltages
    Annex H (normative) - Tests
    Annex I (normative) - Measurement of high-frequency
            leakage current
    Annex J (normative) - Particular additional safety
            requirements for a.c., a.c./d.c. or d.c. supplied
            electronic control gear for emergency lighting
    Annex K (informative) - Components used in the
            asymmetric pulse test circuit
    Annex L (normative) - Information for controlgear design
    Bibliography
    Annex ZA (normative) - Normative references to international
             publications with their corresponding European
             publications

    Abstract - (Show below) - (Hide below)

    Describes the electronic control gear for use on a.c. and d.c. supplies up to 1000 V at 50 Hz or 60 Hz with operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation.

    General Product Information - (Show below) - (Hide below)

    Committee CT 34
    Development Note Classificazione CEI 34-94. (01/2002) Supersedes CEI EN 60928. (02/2003) To be read in conjunction with CEI EN 61347-1. (07/2005) Supersedes CEI EN 61347-2-4, CEI EN 61347-2-5, CEI EN 61347-2-6 & CEI EN 60925. (03/2012) AMD 1 Issued on 01/10/2017 is only available in English. (12/2017)
    Document Type Standard
    Publisher Comitato Elettrotecnico Italiano
    Status Current
    Supersedes

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
    IEC 61347-1:2015 RLV Lamp controlgear - Part 1: General and safety requirements
    EN 60929:2011/A1:2016 AC AND/OR DC-SUPPLIED ELECTRONIC CONTROL GEAR FOR TUBULAR FLUORESCENT LAMPS - PERFORMANCE REQUIREMENTS
    IEC 60929:2011+AMD1:2015 CSV AC and/or DC-supplied electronic control gear for tubularfluorescent lamps - Performance requirements
    IEC 61199:2011+AMD1:2012+AMD2:2014 CSV Single-capped fluorescent lamps - Safety specifications
    EN 61347-2-7:2012 Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
    EN 61347-1:2015 Lamp controlgear - Part 1: General and safety requirements
    IEC 61347-2-7:2011+AMD1:2017 CSV Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)
    IEC 60598-2-22:2014+AMD1:2017 CSV Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting
    EN 61547:2009 Equipment for general lighting purposes - EMC immunity requirements
    IEC TS 60479-2:2007 Effects of current on human beings and livestock - Part 2: Special aspects
    IEC 61195:1999+AMD1:2012+AMD2:2014 CSV Double-capped fluorescent lamps - Safety specifications
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective