CEI EN 61442 : 2006
Current
The latest, up-to-date edition.
TEST METHODS FOR ACCESSORIES FOR POWER CABLES WITH RATED VOLTAGES FROM 6 KV (U[M] = 7,2 KV) UP TO 36 KV (U[M] = 42 KV)
Hardcopy , PDF
English - Italian
01-01-2006
1 Scope
2 Normative references
3 Test installations and conditions
4 AC voltage tests
5 DC voltage tests
6 Impulse voltage tests
7 Partial discharge test
8 Tests at elevated temperature
9 Heating cycles voltage test
10 Thermal short-circuit test (screen)
11 Thermal short-circuit test (conductor)
12 Dynamic short-circuit test
13 Humidity and salt fog tests
14 Impact test at ambient temperature
15 Screen resistance measurement
16 Screen leakage current measurement
17 Screen fault current initiation test
18 Operating force test
19 Operating eye test
20 Capacitive test point performance
Annex A (informative) - Determination of the cable
conductor temperature
Annex B (informative) - Details of the test chamber
and spray equipment for
humidity and salt fog tests
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes the test methods to be used for type testing accessories for power cables with rated voltages from 6 kV (U[M] = 7,2 kV) up to 36 kV (U[M] = 42 kV).
Committee |
CT 20
|
DevelopmentNote |
Classificazione CEI 20-61. (08/2005) Supersedes CEI 20-61 V1. (05/2008)
|
DocumentType |
Standard
|
Pages |
66
|
PublisherName |
Comitato Elettrotecnico Italiano
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 61442:2005 | Identical |
IEC 61442:2005 | Identical |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60055-1:1997+AMD1:2005 CSV | Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60986:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
EN 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 36 kV (Um = 42 kV) - Part 1: Test methods and requirements |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
CEI 42-3 : 2ED 1997 | |
IEC 60885-3:2015 RLV | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
CEI 20-34 : 1ED 1985 | METODI DI PROVA PER ISOLANTI E GUAINE DEI CAVI ELETTRICI RIGIDI E FLESSIBILI (MESCOLE ELASTOMERICHE E TERMOPLASTICHE) |
HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60811-1-2:1985 | Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods |
IEC 61238-1:2003 | Compression and mechanical connectors for power cables for rated voltages up to 30 kV (Um = 36 kV) - Part 1: Test methods and requirements |
EN 60811-1-2:1995/A2:2000 | INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS |
EN 60885-3:2015 | Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables |
EN 60230:2002 | Impulse tests on cables and their accessories |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
CEI 42-4 : 1997 | TECNICHE DI PROVA AD ALTA TENSIONE - PARTE 1: DEFINIZIONI E PRESCRIZIONI GENERALI RELATIVE ALLE PROVE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.