CEN/TR 16638:2014
Current
The latest, up-to-date edition.
Non-destructive testing - Penetrant and magnetic particle testing using blue light
19-02-2014
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Safety precautions
5 General principles
6 Equipment
7 Test products
8 Viewing conditions
9 Verification and calibration of instruments
10 Qualification records
11 Test report
Annex A (normative) - Measurement of fluorescent
coefficient
Bibliography
This Technical Report specifies the requirements for penetrant and magnetic particle testing, the materials and viewing conditions when using fluorescent detection media excited by actinic blue light.It is not intended that this sub-method technique is used as a substitute for the existing colour contrast and fluorescent techniques standardised in the EN ISO 3452 series and EN ISO 9934 series.
Committee |
CEN/TC 138
|
DocumentType |
Technical Report
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-CEN/TR 16638:2014 | Identical |
PD CEN/TR 16638:2014 | Identical |
NEN NPR CEN/TR 16638 : 2014 | Identical |
S.R. CEN/TR 16638:2014 | Identical |
FD CEN/TR 16638 : 2014 FD | Identical |
DIN CEN/TR 16638;DIN SPEC 19273:2014-05 | Identical |
CEN/TS 17100:2017 | Non-destructive testing - Penetrant testing - Reference photographs and sizing of indications |
PD CEN/TS 17100:2017 | Non-destructive testing. Penetrant testing. Reference photographs and sizing of indications |
S.R. CEN/TS 17100:2017 | NON-DESTRUCTIVE TESTING - PENETRANT TESTING - REFERENCE PHOTOGRAPHS AND SIZING OF INDICATIONS |
PD CEN/TS 17108:2017 | Non-destructive testing. Lighting in penetrant and magnetic particle testing, good practice |
S.R. CEN/TR 17108:2017 | NON-DESTRUCTIVE TESTING - LIGHTING IN PENETRANT AND MAGNETIC PARTICLE TESTING, GOOD PRACTICE |
CEN/TR 17108:2017 | Non-destructive testing - Lighting in penetrant and magnetic particle testing, good practice |
ISO 3452-6:2008 | Non-destructive testing Penetrant testing Part 6: Penetrant testing at temperatures lower than 10 degrees C |
EN ISO 3452-2:2013 | Non-destructive testing - Penetrant testing - Part 2: Testing of penetrant materials (ISO 3452-2:2013) |
EN ISO 3452-1:2013 | Non-destructive testing - Penetrant testing - Part 1: General principles (ISO 3452-1:2013, Corrected version 2014-05-01) |
ISO 9712:2012 | Non-destructive testing Qualification and certification of NDT personnel |
ISO 3059:2012 | Non-destructive testing — Penetrant testing and magnetic particle testing — Viewing conditions |
EN ISO 3452-3:2013 | Non-destructive testing - Penetrant testing - Part 3: Reference test blocks (ISO 3452-3:2013) |
CEN/TR 14748:2004 | Non-destructive testing - Methodology for qualification of non-destructive tests |
EN ISO 9934-3:2015 | Non-destructive testing - Magnetic particle testing - Part 3: Equipment (ISO 9934-3:2015) |
EN ISO 9712:2012 | Non-destructive testing - Qualification and certification of NDT personnel (ISO 9712:2012) |
ISO 3452-1:2013 | Non-destructive testing Penetrant testing Part 1: General principles |
EN ISO 9934-1:2016 | Non-destructive testing - Magnetic particle testing - Part 1: General principles (ISO 9934-1:2016) |
EN ISO 3452-6:2008 | Non-destructive testing - Penetrant testing - Part 6: Penetrant testing at temperatures lower than 10 degrees C (ISO 3452-6:2008) |
ISO 3452-3:2013 | Non-destructive testing — Penetrant testing — Part 3: Reference test blocks |
ISO 3452-2:2013 | Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials |
ISO 9934-1:2016 | Non-destructive testing — Magnetic particle testing — Part 1: General principles |
ISO 9934-2:2015 | Non-destructive testing — Magnetic particle testing — Part 2: Detection media |
ISO 9934-3:2015 | Non-destructive testing — Magnetic particle testing — Part 3: Equipment |
EN ISO 3452-5:2008 | Non-destructive testing - Penetrant testing - Part 5: Penetrant testing at temperatures higher than 50 degrees C (ISO 3452-5:2008) |
EN ISO 9934-2:2015 | Non-destructive testing - Magnetic particle testing - Part 2: Detection media (ISO 9934-2:2015) |
EN ISO 12706:2009 | Non-destructive testing - Penetrant testing - Vocabulary (ISO 12706:2009) |
EN 1330-7:2005 | Non-destructive testing - Terminology - Part 7: Terms used in magnetic particle testing |
ISO 12706:2009 | Non-destructive testing Penetrant testing Vocabulary |
EN ISO 3059:2012 | Non-destructive testing - Penetrant testing and magnetic particle testing - Viewing conditions (ISO 3059:2012) |
ISO 3452-5:2008 | Non-destructive testing Penetrant testing Part 5: Penetrant testing at temperatures higher than 50 degrees C |
ISO 3452-4:1998 | Non-destructive testing Penetrant testing Part 4: Equipment |
EN ISO 3452-4:1998 | Non-destructive testing - Penetrant testing - Part 4: Equipment (ISO 3452-4:1998) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.