    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Operating condition of water spray systems
    5 Fire hazards and system design
    6 Simultaneous operation of water spray installations
    7 Special considerations for water spray systems
    8 System activation
    9 Sprayer design characteristics and uses
    Annex A (informative)- Exposure protection
    Bibliography

    Abstract - (Show below) - (Hide below)

    This standard specifies requirements and gives recommendations for the design, installation and maintenance of fixed deluge water spray systems internal and external to buildings and industrial plant and other premises on land. This standard covers only the use of the types of sprinklers and sprayers specified in EN 12259-1. The requirements and recommendations of this standard are also applicable to any addition, extension, repair or other modification to a water spray system. This standard does not deal with sprinkler systems.It covers the hazards, provision of water supplies, components to be used, installation and testing of the system, maintenance, and the extension of existing systems, and identifies construction details of buildings which are necessary for the satisfactory performance of water spray systems complying with this standard.The general principles may well apply to other uses (e.g. maritime use), for these other uses additional considerations will almost certainly have to be taken into account.For water spray systems covered by this standard the authority shall be consulted.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 191
    Document Type Technical Specification
    Publisher Comite Europeen de Normalisation
    Status Current

    Standards Referenced By This Book - (Show below) - (Hide below)

    13/30279579 DC : 0 BS ISO 19372 - MICROTURBINES APPLICATIONS - SAFETY
    I.S. EN 50600-2-5:2016 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    EN 50600-2-5:2016 Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems
    ISO 19372:2015 Microturbines applications — Safety
    CEI EN 50600-2-5 : 2017 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    ISO/IEC TS 22237-6:2018 Information technology Data centre facilities and infrastructures Part 6: Security systems
    BS ISO 19372:2015 Microturbines applications. Safety
    16/30339494 DC : 0 BS EN 13565-2 - FIXED FIREFIGHTING SYSTEMS - FOAM SYSTEMS - PART 2: DESIGN, CONSTRUCTION AND MAINTENANCE
    PREN 13565-2 : DRAFT 2016 FIXED FIREFIGHTING SYSTEMS - FOAM SYSTEMS - PART 2: DESIGN, CONSTRUCTION AND MAINTENANCE

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
    EN 54-2:1997/A1:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT
    EN 12259-2:1999/A2:2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 2: WET ALARM VALVE ASSEMBLIES
    PREN 12259-9 : DRAFT 2016 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 9: DELUGE ALARM VALVES
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    EN 54-10:2002/A1:2005 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS
    EN 54-3:2014 Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders
    ISO 9001:2015 Quality management systems — Requirements
    EN 12259-3:2000/A2:2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 3: DRY ALARM VALVE ASSEMBLIES
    EN 12259-1:1999 + A1:2001/A3:2006 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 1: SPRINKLERS
    EN 54-4:1997/A2:2006 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT
    EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
    EN 54-11:2001/A1:2005 FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective