CEN/TS 16272-7:2015
Current
The latest, up-to-date edition.
Railway applications - Track - Noise barriers and related devices acting on airborne sound propagation - Test method for determining the acoustic performance - Part 7: Extrinsic characteristics - In situ values of insertion loss
30-09-2015
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 Methods
6 Instrumentation
7 Acoustic environment
8 Sources and source equivalence
9 Measurement procedure
10 Measurement uncertainty
11 Test report
Annex A (informative) - Measurement uncertainty
Bibliography
This Technical Specification specifies methods for the determination of insertion loss of outdoor noise barriers intended to shield railway noise. It specifies detailed procedures for in situ measurement of barrier insertion loss including microphone positions, source conditions and acoustic environments of the measurement sites.This Technical Specification allows one to measure the insertion loss of a given noise barrier at a given site including given meteorological conditions. It does not make it possible to compare insertion loss values of an equivalent barrier at a different site. It can be used for comparing insertion loss values of different types of barriers at the same site under given meteorological conditions by the "direct method".This Technical Specification gives a method for determining insertion loss:a)from the level difference before and after the installation of noise barriers (the "direct method") and when this is not possible because a barrier has already been installed;b)using an indirect method to estimate the sound pressure levels before installation of the barrier by measurement at another site which has been judged to be equivalent.For equivalent sites, a close match is required in source characteristics, microphone locations, terrain profiles ground surface characteristics, surrounding artificial structures and meteorological conditions. This Technical Specification prescribes principles for ensuring that sufficiently equivalent conditions are maintained between "before" and "after" cases to permit certain, reliable and repeatable determination of barrier insertion loss.This Technical Specification does not cover the determination of the intrinsic acoustic characteristics of the barrier, for example the sound insulation index and the sound absorption coefficient.The equivalent continuous A-weighted sound pressure level and one-third-octave band sound pressure level are used as noise descriptors.This Technical Specification can be used for routine determination of barrier performance or for engineering or diagnostic evaluation. It can be used in situations where the barrier is to be installed or has already been installed.
Committee |
CEN/TC 256
|
DocumentType |
Technical Specification
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN CEN/TS 16272-7;DIN SPEC 1638:2015-12 | Identical |
UNE-CEN/TS 16272-7:2015 | Identical |
S.R. CEN/TS 16272-7:2015 | Identical |
UNI CEN/TS 16272-7 : 2015 | Identical |
PD CEN/TS 16272-7:2015 | Identical |
EN 16272-3-2:2014 | Railway applications - Track - Noise barriers and related devices acting on airborne sound propagation - Test method for determining the acoustic performance - Part 3-2: Normalized railway noise spectrum and single number ratings for direct field applications |
IEC 60942:2003 | Electroacoustics - Sound calibrators |
ISO 9613-1:1993 | Acoustics Attenuation of sound during propagation outdoors Part 1: Calculation of the absorption of sound by the atmosphere |
EN 61672-1:2013 | Electroacoustics - Sound level meters - Part 1: Specifications |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
EN 60942:2003 | Electroacoustics - Sound calibrators |
EN 61260:1995/A1:2001 | ELECTROACOUSTICS - OCTAVE-BAND AND FRACTIONAL-OCTAVE-BAND FILTERS |
EN 16272-3-1:2012 | Railway applications - Track - Noise barriers and related devices acting on airborne sound propagation - Test method for determining the acoustic performance - Part 3-1: Normalized railway noise spectrum and single number ratings for diffuse field applications |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-