CISPR 16-4:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Specification for radio disturbance and immunity measuring apparatus and methods - Part 4: Uncertainty in EMC measurements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
26-11-2003
English - French
29-05-2002
FOREWORD
1 Scope
2 Normative references
3 Definitions and symbols
3.1 General symbols
3.2 Measurands
3.3 Input quantities
4 Measurement instrumentation uncertainty
4.1 Overview
4.2 Quantities to be considered for conducted
disturbance measurements at a mains port
4.3 Quantities to be considered for disturbance power
measurements
4.4 Quantities to be considered for radiated
disturbance measurements of electric field strength
on an open area test site or alternative test site
Annex A (informative) Basis for U[cispr] values in Table 1
Bibliography
This part of CISPR 16 is designated a basic standard, which specifies the manner in which measurement uncertainty is to be taken into account in determining compliance with CISPR limits. The material is also relevant to any EMC test when interpretation of the results and conclusions reached will be impacted by the uncertainty of the instrumentation used during the testing.
DocumentType |
Standard
|
Pages |
37
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
BS CISPR 16-4:2002 | Identical |
DIN EN 55016-4 : DRAFT 2004 | Identical |
VDE 0876-16-4 : DRAFT 2004 | Identical |
DIN EN 55016-4 : DRAFT 2004 | Corresponds |
PNE-prEN 55016-4 | Identical |
TS 103 051 : 1.1.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); EXPANDED MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS |
04/30118430 DC : DRAFT AUG 2004 | EN 50420 - BASIC STANDARD FOR THE EVALUATION OF HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS FROM A STAND ALONE BROADCAST TRANSMITTER (30 MHZ - 40 GHZ) |
03/108397 DC : DRAFT MAY 2003 | IEC CISPR 22 ED.4 AMD 2 - INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT - NEW CLAUSE 11: MEASUREMENT UNCERTAINTY |
TR 102 215 : 1.3.1 | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); RECOMMENDED APPROACH, AND POSSIBLE LIMITS FOR MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS ABOVE 1 GHZ |
EG 202 290 : 1.1.1 FINAL DRAFT | ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); MEASUREMENT UNCERTAINTIES AND TEST METHODOLOGIES FROM 1 GHZ TO 40 GHZ |
CISPR 16-2:2003 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
CISPR TR 16-3:2010+AMD1:2012+AMD2:2015 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 3: CISPR technical reports |