Electromagnetic compatibility - Emission measurements in fully anechoic chambers
12-03-2010
1 Scope
2 References
3 Definitions and abbreviations
4 Test and measurement equipment
5 Anechoic room performance
6 Emission measurement
7 Test procedure
8 Test plan
9 Test report
Annex A (informative) - Determining the Site Reference
Annex B (informative) - Limit values
Annex C (informative) - Comparison of measurement uncertainties
for 3 m OATS and 3 m FAR
Annex D (informative) - Derivation of free space NSA formula
Annex E (informative) - Corrections of field strength for test
distance
Annex F (informative) - NSA measurements with biconical antennas
Annex G (informative) - Measurement of Balun imbalance
Annex H (informative) - FAR project
Bibliography
This Technical Report applies to emission measurements of radiated electromagnetic fields in Fully Anechoic Rooms (FAR) in the frequency range from 30 MHz to 18 GHz. This Technical Report covers the frequency range from 30 MHz – 1 000 MHz. The frequency range above 1 GHz is under consideration, due to the absence of practical experience. This Technical Report describes the validation procedure for the Fully Anechoic Room for radiated emission tests and the procedures to carry out the tests (e.g. test set up, EUT position, cable layout and termination, test procedures). Recommendations for the relation between FAR emission limits and common Open Area Test Site (OATS) emission limits given in standards such as EN 55011 and EN 55022 are given in Annex B. This FAR emission method may be chosen by product committees as an alternative method to emission measurement on an Open Area Test Site (OATS) as described in CISPR 16 series. In such cases, the product committee should also define the appropriate limits. Typical measurement uncertainty values for FARs and OATS are given in Annex C.
Committee |
CLC/TC 210
|
DevelopmentNote |
Supersedes R210-010. (04/2010)
|
DocumentType |
Technical Report
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PD CLC/TR 50485:2010 | Identical |
CEI CLC/TR 50485 : 2013 | Identical |
NEN NPR CLC/TR 50485 : 2010 | Identical |
S.R. CLC/TR 50485:2010 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
CLC/TR 50484:2009 | Recommendations for shielded enclosures |
EN 50147-1:1996 | Anechoic chambers - Part 1: Shield attenuation measurement |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
EN 55022:2010/AC:2011 | INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008) |
CISPR 16-2:2003 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity |
ANSI C63.5 : 2006 | ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
CISPR 16-1:1999+AMD1:2002 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.