• Shopping Cart
    There are no items in your cart

CLC/TR 62271-303:2009

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 303: USE AND HANDLING OF SULPHUR HEXAFLUORIDE (SF[6])

Superseded date

01-11-2013

Superseded by

EN 62271-4 : 2013

Published date

12-01-2013

Sorry this product is not available in your region.

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Storage and transportation of SF[6]
5 Safety and first aid
6 Training and certification
7 SF[6] handling during installation and commissioning
8 SF[6] handling during normal service life
9 SF[6] recovering and reclaiming during maintenance
10 Dismantling of SF[6] electric power equipment at
   the end-of-life
11 Description of SF[6] handling equipment
Annex A (informative) - Sulphur hexafluoride
Annex B (informative) - Environmental effects of SF[6]
Annex C (informative) - SF[6] by-products
Annex D (informative) - Potential effects on health of SF[6]
                        by-products
Bibliography
Annex ZA (normative) - Normative references to international
                       publications with their corresponding
                       European publications

Describes the procedures for safe and environmental compatible handling of SF[6] during installation, commissioning, normal and abnormal operations, disposal at the end-of-life of high-voltage switchgear and controlgear.

DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Superseded
SupersededBy

CEI EN 62271-204 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES ABOVE 52 KV
BS EN 62271-203:2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
BS EN 62271-200:2012 High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
UNE-EN 62271-203:2013 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
UNE-EN 62271-204:2012 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
I.S. EN 61936-1:2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
BS EN 61936-1 : 2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES
UNE-EN 61936-1:2012 Power installations exceeding 1 kV a.c. -- Part 1: Common rules
EN 62271-204:2011 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
CEI EN 62271-203 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
I.S. EN 62271-204:2011 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 204: RIGID GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGE ABOVE 52 KV (IEC 62271-204:2011 (EQV))
BS EN 62271-204:2011 High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV
I.S. EN 62271-203:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV))
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
EN 60376:2005 Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
EN 60480:2004 Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use
IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60695-7-1:2010 Fire hazard testing - Part 7-1: Toxicity of fire effluent - General guidance
ISO 14040:2006 Environmental management Life cycle assessment Principles and framework

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.