CLC/TS 50131-2-8:2012
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Alarm systems - Intrusion and hold-up systems - Part 2-8: Intrusion detectors - Shock detectors
10-03-2023
13-04-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Functional requirements
5 Marking, identification and documentation
6 Testing
Annex A (normative) - Standard test material
Annex B (normative) - Dimensions and requirements of the
standardised Test Magnets
Annex C (normative) - General Testing Matrix
Annex D (normative) - Standard immunity glass pane
Annex E (normative) - Spring operated Hammer
Annex F (informative) - Example list of small tools
Annex G (normative) - Minimum performance requirements
gross and shock integration attack tests
Annex H (normative) - Immunity test: Small objects hit
sensitivity
Annex I (normative) - Immunity test: Hard objects hit
sensitivity
Annex J (normative) - Immunity test: Static pressure
sensitivity
Annex K (normative) - Immunity test: Dynamic pressure
sensitivity
Bibliography
This Technical Specification is for shock detectors installed in buildings to detect the shock or series of shocks due to a forcible attack through a physical barrier (for example doors or windows). It provides for security Grades 1-4 (see EN 50131-1), specific or non specific wired or wire-free detectors and uses Environmental Classes i-iv (see EN 50130-5). This Technical Specification does not include requirements for detectors intended to protect for example vaults and safes from penetration attacks from e.g. drilling, cutting or thermal lance. This Technical Specification does not include requirements for shock detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this Technical Specification may be included in the detector, providing they do not adversely influence the correct operation of the mandatory functions. This Technical Specification does not apply to system interconnections.
Committee |
CLC/TC 79
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy |
Standards | Relationship |
VDE V 0830-2-2-8 : 2013 | Identical |
NEN NPR CLC/TS 50131-2-8 : 2012 | Identical |
DIN CLC/TS 50131-2-8 : 2013 | Identical |
CEI CLC/TS 50131-2-8 : 2013 | Identical |
PD CLC/TS 50131-2-8:2012 | Identical |
S.R. CLC/TS 50131-2-8:2012 | Identical |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60404-8-1:2015 | Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
IEC 60404-14:2002 | Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60404-5:2015 RLV | Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties |
EN 50131-1:2006/A2:2017 | ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS |
EN 50131-6:2017 | Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 60404-5:2015 | Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60404-14:2002 | Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 50130-5:2011 | ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS |