CLC/TS 50429:2005
Current
The latest, up-to-date edition.
Optical fibre cables - Sewer cables - Family specification for cables to be installed in storm and sanitary sewers
10-02-2005
1 Scope
2 Normative references
3 Symbols
4 Family specification for sewer cables and conduits for
installation by blowing and/or pulling in sewers (blank
detail specification and minimum requirements)
4.1 Construction
4.1.1 General
4.1.2 Conduits
4.1.3 Sewer cables
4.1.4 Rodent protection
4.2 Product descriptions
4.2.1 Sewer cables description
4.2.2 Conduit description
4.3 Optical fibres
4.3.1 Single-mode dispersion unshifted (B1.1) optical
fibre
4.3.2 Single mode dispersion shifted (B2) optical
fibre
4.3.3 Single mode non-zero dispersion (B4) optical
fibre
4.3.4 Multimode fibres
4.4 Sewer cable constructions
4.4.1 Cable for installation within conduits (previously
fixed to the sewer wall)
4.4.2 Cable for direct installation into the sewer duct
4.4.3 Conduit construction
4.5 Installation and operating conditions
4.5.1 Tests applicable
4.5.2 Installation conditions
4.6 Mechanical and environmental tests
4.6.1 Conduit
4.6.2 Cable for installation within conduits (previously
fixed to the sewer wall)
4.6.3 Cables for direct installation into the sewer duct
4.7 Examples of conduits and sewer cables
4.7.1 Cables for installation within conduits
4.7.2 Cables for direct installation into the sewer duct
4.8 Examples of installation schemes
4.8.1 Installation within conduits
4.8.2 Installation directly into the sewer
Annex A (informative) - O.F. cables for non-man-accessible sewers
This document is a family specification that covers sewer cables and conduits for installation by blowing and/ or pulling in non-man accessible storm and sanitary sewers, also applicable for man-accessible and lateral ones. Systems built with components covered by this standard are subject to the requirements of sectional specifications EN 60794-3 and EN 60794-4 where applicable. Sewer cable and conduit constructions have to meet the different requirements of the sewer operating companies and / or associations regarding chemical, environmental, operational, cleaning and in general maintenance conditions. A table of preferential applications, describing sewer cable characteristics versus methods of installation is reported in Annex A for non-man accessible sewers. Clause 4 describes a blank detail specification for sewer cables and conduits for installation by blowing and/or pulling in storm and sanitary sewers. It incorporates some minimum requirements. Detail specifications may be prepared on the basis of this family specification. The parameters specified in this standard may be affected by measurement uncertainty arising either from measurement errors or calibration errors due to lack of suitable standards. Acceptance criteria should be interpreted with respect to this consideration. The number of fibres tested is representative of the sewer cable and should be agreed between the customer and supplier.
| Committee |
CLC/TC 86A
|
| DocumentType |
Technical Specification
|
| PublisherName |
European Committee for Standards - Electrical
|
| Status |
Current
|
| Standards | Relationship |
| I.S. CLC TS 50429:2005 | Identical |
| CEI CLC/TS 50429 : 2005 | Identical |
| NEN NPR CLC/TS 50429 : 2005 | Identical |
| DD CLC/TS 50429:2005 | Identical |