Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 22: Selection and application principles - Wind turbine applications
14-05-2010
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Equipment to be protected
6 Configuration of a typical wind turbine
7 Protection of power circuits within a wind turbine
Annex A (informative) - Typical values of vibration
withstand of SPDs used in wind turbine systems
Bibliography
This Technical Specification applies to surge protection of wind turbine generators and wind power systems. Normative references are made to generic standards for lightning protection, low-voltage systems and high-voltage systems for machinery and installations and electromagnetic compatibility (EMC). This Technical Specification defines requirements for selection and installation of surge protective devices for the power circuits. Some special information about particular testing are also included since there is not a current standard for testing surge protective devices for wind turbines.
Committee |
CLC/TC 37A
|
DocumentType |
Technical Specification
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Current
|
Standards | Relationship |
DIN CLC/TS 50539-22 : 2010 | Identical |
VDE V 0675-39-22 : 2010 | Identical |
CEI CLC/TS 50539-22 : 2012 | Identical |
DD CLC/TS 50539-22:2010 | Identical |
NEN NPR CLC/TS 50539-22 : 2010 | Identical |
S.R. CLC/TS 50539-22:2010 | Identical |
IEC TR 61400-24:2002 | Wind turbine generator systems - Part 24: Lightning protection |
EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
CLC/TS 50539-12:2013 | Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 12: Selection and application principles - SPDs connected to photovoltaic installations |
IEC 61643-12:2008 | Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power distribution systems - Selection and application principles |
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV | Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods |
EN 62305-4:2011/AC:2016-11 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-1:2010 | Protection against lightning - Part 1: General principles |
EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
IEC 61643-22:2015 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
IEC 61643-1:2005 | Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests |
EN 61400-24:2010 | Wind turbines - Part 24: Lightning protection |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
EN 61643-21:2001/A2:2013 | LOW VOLTAGE SURGE PROTECTIVE DEVICES - PART 21: SURGE PROTECTIVE DEVICES CONNECTED TO TELECOMMUNICATIONS AND SIGNALLING NETWORKS - PERFORMANCE REQUIREMENTS AND TESTING METHODS (IEC 61643-21:2000/A2:2012) |
EN 62305-2:2012 | Protection against lightning - Part 2: Risk management |
CLC/TS 61643-12:2009 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
CLC/TS 61643-22:2016 | Low-voltage surge protective devices - Part 22: Surge protective devices connected to telecommunications and signalling networks - Selection and application principles |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-