CLSI EP17 A2 : 2ED 2012
Current
The latest, up-to-date edition.
EVALUATION OF DETECTION CAPABILITY FOR CLINICAL LABORATORY MEASUREMENT PROCEDURES
Hardcopy , PDF
English
18-06-2012
Abstract
Committee Membership
Foreword
1 Scope
2 Standard Precautions
3 Terminology
4 Background
5 Protocols for Evaluation of the Limit of Blank
and Limit of Detection
6 Protocol for Evaluation of the Limit of Quantitation
7 Verification of Detection Capability Claims
8 Reporting Detection Capability
References
Appendix A - Worked Example: Evaluation of Limits
of Blank and Detection by the Classical
Approach
Appendix B - Worked Example: Evaluation of Limit
of Detection by the Precision Profile Approach
Appendix C - Worked Example: Evaluation of Limit
of Detection by the Probit Approach
Appendix D - Worked Examples: Evaluation of Limit
of Quantitation
Appendix E - Worked Example: Verification of Limits
of Blank and Detection Claims
Appendix F - Worked Example: Verification of Limit
of Quantitation Claim
The Quality Management System Approach
Related CLSI Reference Materials
Gives guidance for evaluation and documentation of the detection capability of clinical laboratory measurement procedures (ie, limits of blank, detection, and quantitation), for verification of manufacturers' detection capability claims, and for the proper use and interpretation of different detection capability estimates.
| DevelopmentNote |
Supersedes CLSI EP17 A. (07/2012)
|
| DocumentType |
Miscellaneous Product
|
| ISBN |
1-56238-796-0
|
| Pages |
80
|
| PublisherName |
Clinical Laboratory Standards Institute
|
| Status |
Current
|
| Supersedes |
| CLSI EP43 ED1:2021 | Implementing a Laboratory Test Under Emergency Use Conditions, 1st Edition |
| CLSI EP35 : 2019 | Assessment of Equivalence or Suitability of Specimen Types for Medical Laboratory Measurement Procedures, 1st Edition |
| CLSI C49:2018(R2023) | Analysis of Body Fluids in Clinical Chemistry |
| CLSI EP12:2023 | Evaluation of Qualitative, Binary Output Examination Performance |
| CLSI EP39 ED1:2021 | A Hierarchical Approach to Selecting Surrogate Samples for the Evaluation of In Vitro Medical Laboratory Tests |
| CLSI EP35:2025 | Assessment of Equivalence or Suitability of Specimen Types for Medical Laboratory Measurement Procedures |
| CLSI EP34:2018(R2023) | Establishing and Verifying an Extended Measuring Interval Through Specimen Dilution and Spiking |
| CLSI EP05-A3:2014(R2019) | Evaluation of Precision of Quantitative Measurement Procedures; Approved Guideline—Third Edition |
| CLSI EP06 ED2:2020 | Evaluation of Linearity of Quantitative Measurement Procedures, 2nd Edition |
| CLSI EP14 A2 : 2ED 2005 | EVALUATION OF MATRIX EFFECTS |
| CLSI EP5 A2 : 2ED 2004 | EVALUATION OF PRECISION PERFORMANCE OF QUANTITATIVE MEASUREMENT METHODS |
| CLSI EP12 A2 : 2ED 2008 | USER PROTOCOL FOR EVALUATION OF QUALITATIVE TEST PERFORMANCE |
| CLSI EP6 A : 1ED 2003 | EVALUATION OF THE LINEARITY OF QUANTITATIVE MEASUREMENT PROCEDURES - A STATISTICAL APPROACH |
| CLSI M29 A3 : 3ED 2005 | ACQUIRED INFECTIONS; APPROVED GUIDELINE |
| CLSI EP29 A : 1ED 2012 | EXPRESSION OF MEASUREMENT UNCERTAINTY IN LABORATORY MEDICINE |
| CLSI EP7 A2 : 2ED 2005 | INTERFERENCE TESTING IN CLINICAL CHEMISTRY |
| CLSI MM3 A2 : 2ED 2006 | MOLECULAR DIAGNOSTIC METHODS FOR INFECTIOUS DISEASES |