CR 14377:2002
Current
The latest, up-to-date edition.
Air quality - Approach to uncertainty estimation for ambient air reference measurement methods
16-01-2002
Foreword
1 Introduction
2 Assumption and interpretations in this Report of the
EC Air Quality Framework and Daughter Directives
2.1 Annexes to the Daughter Directives
2.2 Definitions and interpretation pf measurement
uncertainty, level of confidence, and confidence
interval, within the Ambient Air Quality Daughter
Directives
3 EC Terms of Reference
3.1 General
3.2 Guide to the Expression of Uncertainty in Measurement
3.3 International Standards ISO 5725 Parts 1 to 6
3.4 International Vocabulary of Basic and General Terms
in Metrology
3.5 Other International Standards
4 Recommendations for the assessment of uncertainty of
ambient air measurement methods
4.1 Introduction
4.2 Consistent approach to the assessment of uncertainty
in the Ambient Air Quality Daughter Directives
5 Requirements for on-going quality assurance and quality
control of field measurements covered by the EC Directives
5.1 Overview of requirements
5.2 Specific requirements of the Framework Directive
5.3 Types of organisations involved
5.4 Requirement for traceability to national or
international accepted standards
5.5 Demonstration of the competence of organisations
involved with QA/QC activities
5.6 The role of quality assurance and quality control
for the on-going field measurements
5.7 Procedures for the regular auditing of the performance
of laboratories involved in QA/QC activities
5.8 Conclusions
6 General philosophy for the development of future ambient air
measurement methods
Annex A - Principles of the Reference Methods prescribed in the
EC Air Quality Daughter Directives
Annex B - Data quality objectives contained in the Ambient Air
Quality Daughter Directive covering benzene and
carbon monoxide
Annex C - Reference measurement method for the implementation
of EU Air Quality Directives
Annex D - Examples illustrating the approach specified in this
Report for uncertainty estimation for ambient air
measurement methods
Annex E - Definitions of measurement uncertainty terms used
in this Report
Annex F - Outline description of a methodology for a proficiency
testing scheme which could be used to underpin
European harmonisation of ambient air quality
measurements
Annex G - Members of the Ad-hoc Group on an approach to
uncertainty estimation for ambient air measurement
methods
Annex H - Acknowledgements
Bibliography
The Report is to provide guidance on uncertainty evaluation to CEN/TC 264 Working Group(s), who are involved in the preparation of Reference Methods to measure ambient air quality, as required by the EU Daughter Directives of the European Framework Directive on Ambient Air-quality Assessment and Management (96/62/EC)
Committee |
CEN/TC 264
|
DocumentType |
Report
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN SPEC 1168:2010-07 | Identical |
UNE-CR 14377:2005 IN | Identical |
I.S. CR 14377:2002 | Identical |
NEN NPR CR 14377 : 2005 | Identical |
I.S. EN 15853:2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF MERCURY DEPOSITION |
03/306292 DC : DRAFT APR 2003 | EN 14662-1 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF BENZENE CONCENTRATION - PART 1: PUMPED SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY METHOD |
UNE-EN 15852:2010 | Ambient air quality - Standard method for the determination of total gaseous mercury |
PREN 14625 : DRAFT 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF OZONE BY ULTRAVIOLET PHOTOMETRY |
08/30175672 DC : DRAFT SEP 2008 | BS EN 15852 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF TOTAL GASEOUS MERCURY |
DIN EN 15853:2010-11 | Ambient air quality - Standard method for the determination of mercury deposition |
10/30210750 DC : 0 | BS EN 14212 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF SULPHUR DIOXIDE BY ULTRAVIOLET FLUORESCENCE |
03/306295 DC : DRAFT APR 2003 | EN 14662-4 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 4: DIFFUSIVE SAMPLING FOLLOWED BY THERMAL DESORPTION AND GAS CHROMATOGRAPHY |
04/19981537 DC : DRAFT MARCH 2004 | EN 14902 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB/CD/AS/NI IN AMBIENT AIR |
DIN EN 13528-2:2002-12 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours; Requirements and test methods - Part 2: Specific requirements and test methods |
EN 13528-2:2002 | Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods |
DIN EN 14907:2005-11 | AMBIENT AIR QUALITY - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM[2,5] MASS FRACTION OF SUSPENDED PARTICULATE MATTER |
08/30175675 DC : DRAFT SEP 2008 | BS EN 15853 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF MERCURY DEPOSITION |
I.S. EN 14907:2005 | AMBIENT AIR QUALITY - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM[2,5] MASS FRACTION OF SUSPENDED PARTICULATE MATTER |
BS EN 15852:2010 | Ambient air quality. Standard method for the determination of total gaseous mercury |
03/306296 DC : DRAFT APR 2003 | EN 14662-5 - AMBIENT AIR QUALITY - STANDARD METHOD FOR MEASUREMENT OF BENZENE CONCENTRATIONS - PART 5: DIFFUSIVE SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
03/306293 DC : DRAFT APR 2003 | EN 14662-1 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF BENZENE CONCENTRATION - PART 2: PUMPED SAMPLING FOLLOWED BY SOLVENT DESORPTION AND GAS CHROMATOGRAPHY |
PREN 14211 : DRAFT 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF NITROGEN DIOXIDE AND NITROGEN MONOXIDE BY CHEMILUMINESCENCE |
PREN 14626 : DRAFT 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF CARBON MONOXIDE BY NONDISPERSIVE INFRARED SPECTROSCOPY |
04/30111960 DC : DRAFT APR 2004 | EN 14907 - AMBIENT AIR QUALITY - REFERENCE GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM2,5 MASS FRACTION OF SUSPENDED PARTICULATE MATTER |
PREN 14212 : DRAFT 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF SULPHUR DIOXIDE BY ULTRAVIOLET FLUORESCENCE |
I.S. EN 15852:2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF TOTAL GASEOUS MERCURY |
UNI EN 15852 : 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF TOTAL GASEOUS MERCURY |
UNI EN 15853 : 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF MERCURY DEPOSITION |
BS EN 14907:2005 | Ambient air quality. Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter |
BS EN 14902:2005 | Ambient air quality. Standard method for the measurement of Pb, Cd, AS, and Ni in the PM 10 fraction of suspended particulate matter |
UNI EN 14902 : 2005 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB, CD, AS AND NI IN THE PM10 FRACTION OF SUSPENDED PARTICULATE MATTER |
NF EN 15852 : 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF TOTAL GASEOUS MERCURY |
BS EN 13528-2:2002 | Ambient air quality. Diffusive samplers for the determination of concentrations of gases and vapours. Requirements and test methods Specific requirements and test methods |
DIN EN 14902:2005-10 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF PB, CD, AS AND NI IN THE PM10 FRACTION OF SUSPENDED PARTICULATE MATTER |
EN 15852:2010 | Ambient air quality - Standard method for the determination of total gaseous mercury |
EN 14907:2005 | Ambient air quality - Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter |
EN 15853:2010 | Ambient air quality - Standard method for the determination of mercury deposition |
DIN EN 15852:2010-11 | Ambient air quality - Standard method for the determination of total gaseous mercury |
10/30210747 DC : 0 | BS EN 14211 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF NITROGEN DIOXIDE AND NITROGEN MONOXIDE BY CHEMILUMINESCENCE |
10/30210756 DC : 0 | BS EN 14626 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF CARBON MONOXIDE BY NONDISPERSIVE INFRARED SPECTROSCOPY |
BS EN 15853:2010 | Ambient air quality. Standard method for the determination of mercury deposition |
10/30210753 DC : 0 | BS EN 14625 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF OZONE BY ULTRAVIOLET PHOTOMETRY |
03/306294 DC : DRAFT APR 2003 | EN 14662-3 - AMBIENT AIR QUALITY - STANDARD METHOD FOR THE MEASUREMENT OF BENZENE CONCENTRATION - PART 3: AUTOMATED PUMPED SAMPLING WITH IN SITU GAS CHROMATOGRAPHIC ANALYSIS |
NF EN 15853 : 2010 | AMBIENT AIR QUALITY - STANDARD METHOD FOR THE DETERMINATION OF MERCURY DEPOSITION |
UNE-EN 15853:2010 | Ambient air quality - Standard method for the determination of mercury deposition |
ISO 5725-1:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions |
ISO 5725-3:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method |
ISO 5725-6:1994 | Accuracy (trueness and precision) of measurement methods and results — Part 6: Use in practice of accuracy values |
ISO 5725-4:1994 | Accuracy (trueness and precision) of measurement methods and results Part 4: Basic methods for the determination of the trueness of a standard measurement method |
ISO 5725-2:1994 | Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method |
ISO 5725-5:1998 | Accuracy (trueness and precision) of measurement methods and results — Part 5: Alternative methods for the determination of the precision of a standard measurement method |
ISO 9169:2006 | Air quality Definition and determination of performance characteristics of an automatic measuring system |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.