• There are no items in your cart

CSA B149.2:20

Current

Current

The latest, up-to-date edition.

Propane storage and handling code

Available format(s)

Hardcopy , PDF

Language(s)

French, English

Published date

01-01-2020

€139.08
Excluding VAT

Preface This is the twelfth edition of CSA B149.2, Propane storage and handling code. It supersedes the previous editions, published in 2015, 2010, 2005, and 2000 by CSA Group (CSA) as CAN/CSA-B149.2, in 1995, 1991, 1986, 1980, 1978, and 1976 by the Canadian Gas Association (CGA), and in 1969 by CSA Group. The main changes from the previous edition are as follows: a) updated Code Scope exclusions (Clause 1.2); b) updated reference publications (Clause 2); c) added requirements for cylinders used on hot air balloon applications (Clauses 6.1.12 and 6.4.7to 6.4.10; d) updated requirements for cylinder exchange (Clauses 6.4.5, 6.5.1.8, 6.5.2.6.1, and 6.5.2.6.2); e) added requirements for handling of cylinders at shows, exhibitions, or other similar events (Clause 6.10 and Annex Q); f) added requirements for handling of cylinders in classrooms (Clause 6.11 and Annex O); g) added requirements for underground tank installations (Clause 7.8.19); h) updated requirements for tank location and support (Clauses 7.10.2, 7.10.3, and 7.11.3 and Table 7.4); i) updated requirements for signage at filling plants and refill centres (Clause 7.12.10); j) updated requirements for protection against vehicular traffic (Clauses 7.19.4.2 and 7.19.4.5); k) updated requirements for vehicle fuel dispensers (Clauses 7.20.12 and 7.20.13); l) updated requirements for vaporizers (Clause 9.1.10, 9.2.4, and 9.3.5); and m) added Annex R — \"Inspection and servicing of pressure relief devices on tanks\". This Code has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Code applies to a) the storage, handling, and transfer of propane; b) propane used as an engine fuel in other than motor vehicles; and c) the installation, operation, and maintenance of containers and equipment to be used for propane at customer locations, in distribution locations and filling plants. 1.2 This Code does not apply to a) transportation of propane; b) manufacture, selection, and use of standardized means of containment under the Transportation of Dangerous Goods Act and Regulations; c) new containers which have not contained propane or used containers identified as having been purged to less than 5% of the LEL as determined by a calibrated gas meter; d) marine or pipeline terminals; e) gas where used as a feedstock in petroleum refineries or chemical plants; f) utility pipeline distribution and transmission pipelines; g) refrigerated storage or underground formations for propane; h) propane used on boats; i) propane used as a propellant in aerosol containers; j) butane fuel cylinders of 6.2 oz (175 g) capacity or less; k) any equipment extending downstream from the inlet to any container pressure regulator (commonly referred to as first-stage regulator); l) the installation of propane fuel system components and containers on vehicles covered by CSA B149.5; and m) propane used as refrigerant. 1.3 Where the term \"propane\" is used, the requirements of this Code include, and apply equally to, any material that is composed predominantly of any of the following hydrocarbons or mixtures of them: propane, propylene, butanes (normal butane or isobutane), and butylenes. 1.4 The values given in yard/pound units are the standard, unless noted otherwise. This Code contains SI (metric) equivalents to yard/pound units so that the Code can be used in SI (metric) units. SI (metric) equivalents may be approximate unless they are the standard. 1.5 In this Code, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Code; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Code. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 This Code and any standards referenced in it do not make or imply any assurance or guarantee with respect to the life expectancy, durability, or operating performance of equipment and materials referenced in the Code.

DocumentType
Standard
ISBN
978-1-4883-2276-1
Pages
152
ProductNote
THIS STANDARD ALSO REFERS:Z240.4.1,CEI 60812,CEI 61882,ULC/ORD-C1275,ULC/ORD-C1349,
PublisherName
Canadian Standards Association
Status
Current
Supersedes

Preface This is the twelfth edition of CSA B149.2, Propane storage and handling code. It supersedes the previous editions, published in 2015, 2010, 2005, and 2000 by CSA Group (CSA) as CAN/CSA-B149.2, in 1995, 1991, 1986, 1980, 1978, and 1976 by the Canadian Gas Association (CGA), and in 1969 by CSA Group. The main changes from the previous edition are as follows: a) updated Code Scope exclusions (Clause 1.2); b) updated reference publications (Clause 2); c) added requirements for cylinders used on hot air balloon applications (Clauses 6.1.12 and 6.4.7to 6.4.10; d) updated requirements for cylinder exchange (Clauses 6.4.5, 6.5.1.8, 6.5.2.6.1, and 6.5.2.6.2); e) added requirements for handling of cylinders at shows, exhibitions, or other similar events (Clause 6.10 and Annex Q); f) added requirements for handling of cylinders in classrooms (Clause 6.11 and Annex O); g) added requirements for underground tank installations (Clause 7.8.19); h) updated requirements for tank location and support (Clauses 7.10.2, 7.10.3, and 7.11.3 and Table 7.4); i) updated requirements for signage at filling plants and refill centres (Clause 7.12.10); j) updated requirements for protection against vehicular traffic (Clauses 7.19.4.2 and 7.19.4.5); k) updated requirements for vehicle fuel dispensers (Clauses 7.20.12 and 7.20.13); l) updated requirements for vaporizers (Clause 9.1.10, 9.2.4, and 9.3.5); and m) added Annex R — \"Inspection and servicing of pressure relief devices on tanks\". This Code has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Code applies to a) the storage, handling, and transfer of propane; b) propane used as an engine fuel in other than motor vehicles; and c) the installation, operation, and maintenance of containers and equipment to be used for propane at customer locations, in distribution locations and filling plants. 1.2 This Code does not apply to a) transportation of propane; b) manufacture, selection, and use of standardized means of containment under the Transportation of Dangerous Goods Act and Regulations; c) new containers which have not contained propane or used containers identified as having been purged to less than 5% of the LEL as determined by a calibrated gas meter; d) marine or pipeline terminals; e) gas where used as a feedstock in petroleum refineries or chemical plants; f) utility pipeline distribution and transmission pipelines; g) refrigerated storage or underground formations for propane; h) propane used on boats; i) propane used as a propellant in aerosol containers; j) butane fuel cylinders of 6.2 oz (175 g) capacity or less; k) any equipment extending downstream from the inlet to any container pressure regulator (commonly referred to as first-stage regulator); l) the installation of propane fuel system components and containers on vehicles covered by CSA B149.5; and m) propane used as refrigerant. 1.3 Where the term \"propane\" is used, the requirements of this Code include, and apply equally to, any material that is composed predominantly of any of the following hydrocarbons or mixtures of them: propane, propylene, butanes (normal butane or isobutane), and butylenes. 1.4 The values given in yard/pound units are the standard, unless noted otherwise. This Code contains SI (metric) equivalents to yard/pound units so that the Code can be used in SI (metric) units. SI (metric) equivalents may be approximate unless they are the standard. 1.5 In this Code, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Code; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Code. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.6 This Code and any standards referenced in it do not make or imply any assurance or guarantee with respect to the life expectancy, durability, or operating performance of equipment and materials referenced in the Code.

CGA V 1 : 2013 STANDARD FOR COMPRESSED GAS CYLINDER VALVE OUTLET AND INLET CONNECTIONS
CGSB 1.184 : 1998 COAL TAR-EPOXY COATING
CSA B51 : 2014 BOILER, PRESSURE VESSEL, AND PRESSURE PIPING CODE
NFPA 30B : 2015 CODE FOR THE MANUFACTURE AND STORAGE OF AEROSOL PRODUCTS
CGSB 3.14 : 2013 COR 1 2015 PROPANE FOR FUEL PURPOSES
CGSB 43.123 : 2017 AEROSOL CONTAINERS AND GAS CARTRIDGES FOR TRANSPORT OF DANGEROUS GOODS
CSA Z240 MH SERIES : 2016 MANUFACTURED HOMES
NFPA 13 : 2016 INSTALLATION OF SPRINKLER SYSTEMS
CSA Z240 RV SERIES : 2014 RECREATIONAL VEHICLES
CGSB 3.13 : M88 LIQUEFIED PETROLEUM GAS (BUTANES)
CFR 40(PTS64-71) : JUL 2017 PROTECTION OF ENVIRONMENT - ENVIRONMENTAL PROTECTION AGENCY
CGA S 1.1 : 2011 PRESSURE RELIEF DEVICE STANDARDS - PART 1: CYLINDERS FOR COMPRESSED GASES
UL 2227:2ED 2007-02-16 Standard for Overfilling Prevention Devices

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.