• Shopping Cart
    There are no items in your cart

CSA C22.2 No. 125 : 1984

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

ELECTROMEDICAL EQUIPMENT

Available format(s)

Hardcopy , PDF

Withdrawn date

06-04-2009

Language(s)

English

Published date

01-01-1999

Technical Committee on Environmental Products
Technical Committee on Electromedical Equipment
Subcommittee on C22.2 No.125
Preface
Introduction
Foreword
1 Scope
2 Definitions
3 General Requirements
    3.1 Reference Publications
    3.2 Standard Classification of Electromedical
          Equipment
    3.3 Safety Criteria
          3.3.1 General
          3.3.2 Risk Current
          3.3.3 Patient Current Accuracy
    3.4 Equipment Sets (or Systems)
4 Construction
    4.1 General
          4.1.1 Electrical Components
          4.1.2 Unassembled Equipment
          4.1.3 Battery Chargers
    4.2 Enclosures
          4.2.1 General
          4.2.2 Enclosure Strength
          4.2.3 Enclosure Durability
          4.2.4 Protection from Electric Shock
          4.2.5 Resistance to Burning
          4.2.6 Confinement of Fire Hazard
          4.2.7 Source of Fire Hazard
          4.2.8 Reduction of Fire Hazard to a Safe
                  Level
    4.3 Mechanical Assembly
          4.3.1 General
          4.3.2 Parts Subjected to Fluid Pressure
          4.3.3 Stability and Transportability
    4.4 Means for Limiting Hazards
          4.4.1 Interlocks
          4.4.2 Capacitor Discharge
          4.4.3 Protection Against Ionizing Radiation
          4.4.4 Equipment for Use in Oxygen Enriched
                  Environments
    4.5 Supply Connections
          4.5.1 General
          4.5.2 Cord-Connected Equipment
          4.5.3 Equipment for Permanent Connection
          4.5.4 Terminal Parts and Leads
    4.6 Interconnections
    4.7 Bushings
    4.8 Internal Wirings
          4.8.1 General
          4.8.2 Protection
          4.8.3 Insulation
          4.8.4 Printed Wiring Boards
    4.9 Motors
    4.10 Transformers
    4.11 Switches and controls
    4.12 Overcurrent, Overload and Overtemperature
          Protection
          4.12.1 General
          4.12.2 Interconnecting Cords and Cables
                  Overcurrent Protection
          4.12.3 Limitation of Secondary Power Input
          4.12.4 Motor Protection
    4.13 Spacings
    4.14 Separation of Circuits
    4.15 Grounding for Protection from Electric Shock
5 Marking
    5.1 General
    5.2 Marking of Therapeutic Equipment
    5.3 Operating Manuals
    5.4 Receptacles
    5.5 Chassis Risk Current
    5.6 Equipment for Permanent Connection
    5.7 Interconnections
    5.8 Double-Insulated Equipment
    5.9 High-Voltage Equipment
    5.10 Transportable Equipment
6 Tests
    6.1 General
    6.2 Conditions for Test
          6.2.1 Test Voltage
          6.2.2 Frequency
          6.2.3 Ambient Temperatures
          6.2.4 Load
          6.2.5 Test Location
    6.3 Risk Current
          6.3.1 General
          6.3.2 Test Arrangements
          6.3.3 Risk Current Test Procedure
    6.4 Patient Current Accuracy Test
    6.5 Rating (Input)
    6.6 Temperature (Normal Load)
    6.7 Dielectric Strength
    6.8 Humidity and Ingress of Fluids Test
    6.9 Abnormal Test
          6.9.1 General
          6.9.2 Compliance
          6.9.3 Test Procedure
    6.10 Deflection Test
    6.11 Endurance Test
          6.11.1 General
          6.11.2 Conditioning Procedure
    6.12 Drop Test
          6.12.1 General
          6.12.2 Procedure
          6.12.3 Compliance
    6.13 Impact Tests for Enclosures and Equipment
          6.13.1 Cathode-Ray Tube Enclosures
          6.13.2 Enclosures for Other than Cathode-Ray
                  Tubes
          6.13.3 Bench Handling Impact Test
    6.14 Extreme Temperature Test
    6.15 Starting
    6.16 Flaming Oil Test for Other than Cathode-Ray
          Tubes
    6.17 Molten PVC and Copper Test
    6.18 Implosion Test for Cathode-Ray Tubes
          6.18.1 General
          6.18.2 Thermite Test
          6.18.3 Liquid Nitrogen
    6.19 Pressure Tests
    6.20 Bond Strength of Printed Wiring Boards
          6.20.1 General
          6.20.2 Test Procedure
    6.21 Test for Stability and Transportability
7 Requirements for Specific Equipment Types
    7.1 General
    7.2 Defibrillators
          7.2.1 Risk Current
          7.2.2 Construction of Defibrillators
    7.3 High Frequency Electromedical Equipment
          7.3.1 General
          7.3.2 Electrosurgery Equipment
          7.3.3 Diathermy Equipment
    7.4 Laser Surgical Equipment
8 Double-Insulated Equipment
    8.1 General
    8.2 Mechanical Assembly
    8.3 Supply Connections
    8.4 Electrical Insulation
    8.5 Transformers
    8.6 Spacings
9 Battery Powered Equipment
    9.1 General
    9.2 Risk Current
    9.3 Resistance to Burning
    9.4 Overcurrent and Overload Protection
Tables
Figures
Appendix A Notes on Requirements
Appendix B Mechanical Hazards
Appendix C Flammability of Enclosures

Applicable to electromedical equipment designed for installation and use according to Part 1 of the Canadian Electrical Code, together with battery-powered equipment, not including battery implantable devices, insofar as the requirements apply.

DocumentType
Standard
Pages
70
ProductNote
Reconfirmed EN
PublisherName
Canadian Standards Association
Status
Withdrawn
SupersededBy

CSA C22.2 No. 63 : 1993 HOUSEHOLD REFRIGERATORS AND FREEZERS
CSA C22.2 No. 49 : 2014 FLEXIBLE CORDS AND CABLES
CSA B51 : 2014 BOILER, PRESSURE VESSEL, AND PRESSURE PIPING CODE
CSA C22.2 No. 77 : 2014 MOTORS WITH INHERENT OVERHEATING PROTECTION
CSA C22.2 No. 0.4 : 2004(R2013) BONDING OF ELECTRICAL EQUIPMENT
CSA C22.2 No. 21 : 2014 CORD SETS AND POWER-SUPPLY CORDS
CSA C22.2 No. 114 : 1990 DIAGNOSTIC IMAGING AND RADIATION THERAPY EQUIPMENT
CSA C22.2 No. 24 : 2015 TEMPERATURE-INDICATING AND -REGULATING EQUIPMENT
CSA C22.2.16 : M86(R1997) INSULATED CONDUCTORS FOR POWER-OPERATED ELECTRONIC DEVICES (rp: 05/87, 03/89, 02/90)
CSA Z32.2 : M89 ELECTRICAL SAFETY IN PATIENT CARE AREAS
CSA C22.2 No. 127 : 2015 EQUIPMENT AND LEAD WIRES
CSA C68.4 : M86 PORTABLE POWER CABLES
CSA C22.2.0.6 : M82 FLAMMABILITY TESTING OF POLYMERIC MATERIALS (rp: 09/83, 01/85, 05/89)
CSA C22.2 No. 66 : 0 SPECIALITY TRANSFORMERS
CSA C22.2 No. 120 : 2013 REFRIGERATION EQUIPMENT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.