CSA C22.2 NO. 137-18
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Electric luminaires for use in hazardous locations
Hardcopy , PDF
07-11-2023
English
01-01-2018
Preface
1 Scope
2 Reference publications
3 Definitions
4 General requirements for all hazardous location
electric luminaires
5 Luminaires for Class I, Division 1, Groups A, B, C
and D
6 Luminaires for Class I, Division 2, Groups A, B, C
and D
7 Luminaires for Class II, Division 1, Groups E, F
and G, and Class III
8 Luminaires for Class II, Division 2, Groups E, F
and G, and Class III
9 Portable luminaires Class I, Division 1 and
Class II, Division
Preface This is the second edition of CSA C22.2 No. 137 Electric Luminaires for Use in Hazardous Locations. One of a series of Standards issued under the Canadian Electrical Code Part II. It supersedes the previous edition published in 1981. Changes to this edition include the a) addition of portable luminaires; and b) removal of requirements covered by other standards. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to fixed and portable luminaires for installation and use in hazardous locations Class I Divisions 1 and 2, Groups A,B,C,D; Class II, Divisions 1 and 2, Groups E,F,G; Class III, Divisions 1 and 2 in accordance with CSA C22.1, Canadian Electrical Code, Part I. 1.1A This Standard does not apply to self-contained replacement lamps or components that alter the original assessment of the fixture. 1.2 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
DocumentType |
Standard
|
ISBN |
978-1-4883-0473-6
|
Pages |
33
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
Supersedes |
Preface This is the second edition of CSA C22.2 No. 137 Electric Luminaires for Use in Hazardous Locations. One of a series of Standards issued under the Canadian Electrical Code Part II. It supersedes the previous edition published in 1981. Changes to this edition include the a) addition of portable luminaires; and b) removal of requirements covered by other standards. This Standard is considered suitable for use for conformity assessment within the stated scope of the Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard applies to fixed and portable luminaires for installation and use in hazardous locations Class I Divisions 1 and 2, Groups A,B,C,D; Class II, Divisions 1 and 2, Groups E,F,G; Class III, Divisions 1 and 2 in accordance with CSA C22.1, Canadian Electrical Code, Part I. 1.1A This Standard does not apply to self-contained replacement lamps or components that alter the original assessment of the fixture. 1.2 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.
CSA C22.2 No. 25 : 1966 | ENCLOSURES FOR USE IN CLASS 2, DIVISION 1, GROUPS E, F, AND G HAZARDOUS LOCATIONS |
CSA C22.2 No. 0.4 : 2004(R2013) | BONDING OF ELECTRICAL EQUIPMENT |
CSA C22.2 No. 0.5 : 2016 | THREADED CONDUIT ENTRIES |
CSA C22.2 No. 60529 : 2016 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) |
CSA C22.2 No. 60079-31 : 2015 | EXPLOSIVE ATMOSPHERES - PART 31: EQUIPMENT DUST IGNITION PROTECTION BY ENCLOSURE 'T' |
C22.2 NO. 213-17 | Nonincendive electrical equipment for use in Class I and II, Division 2 and Class III, Divisions 1 and 2 hazardous (classified) locations (Binational standard with UL 121201) |
CSA C22.2 No. 94.2 : 2015 | ENCLOSURES FOR ELECTRICAL EQUIPMENT, ENVIRONMENTAL CONSIDERATIONS |