CSA C22.2 NO. 198.2:15 (R2020)
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Sealed wire connector systems (Tri-national standard, with UL 486D and NMX-J-519-ANCE)
Hardcopy , PDF
01-01-2023
English
01-01-2015
Preface This is the harmonized ANCE, CSA Group, and UL standard for Sealed wire connector systems . It is the third edition of NMX-J-519-ANCE, the third edition of CSA C22.2 No. 198.2, and the sixth edition of UL 486D. This edition of NMX-J-519-ANCE supersedes the previous edition published in 2006. This edition of CSA C22.2 No. 198.2 supersedes the previous edition published in 2005. This edition of UL 486D supersedes the previous edition published in 2005. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 The requirements in this standard cover sealed wire connector systems, including insulating caps, covers, resins, tubing, and tapes provided with, or for use with, specific wire connectors. These systems are intended for wet or damp locations, and other installations such as direct burial, below grade, or above grade where protected from direct exposure to sunlight. The wire connectors covered by these requirements are intended for use with copper conductor, aluminum conductor, or both in accordance with installations covered by the National Electrical Code, NFPA 70; the Canadian Electrical Code, Part I, C22.1; and NOM 001 SEDE, Standard for Electrical Installations. Note 1: Unless marked for the purpose, these wire connector systems have not been evaluated for direct exposure to sunlight. Additional performance considerations to show equivalency to the connected conductors should be considered for UV exposure. Note 2: These wire connector systems have only been evaluated for fresh water unless marked for direct exposure to salt or seawater. Note 3: These wire connector systems may also be used indoors. 1.2 These requirements also cover sealed wire connector systems intended for use with single or multiple conductor underground feeder cable, golf course sprinkler cable, underground low energy cable, irrigation cable, or other cable with insulation acceptable for direct burial, below grade use, or wet locations. 1.3 These requirements apply to sealed wire connector systems intended for use with 30 AWG (0.05 mm2) through 2,000 kcmil (1,012 mm2) conductors with currents not exceeding the ampacity of insulated conductors rated either 75°C (167°F) or 90°C (194°F) and intended for use at 1500 V or less. 1.4 This standard does not apply to twist-on style splicing sealed wire connectors.600 V or less.
DocumentType |
Standard
|
ISBN |
978-1-77139-893-0
|
Pages |
69
|
ProductNote |
THIS STANDARD ALSO REFERS:NMX-J-543-ANCE-13,NMX-J-548-ANCE-13,NMX-J-553-ANCE,ANSI C119.1-2011,NOM-001-SEDE
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Preface This is the harmonized ANCE, CSA Group, and UL standard for sealed wire connector systems . It is the third edition of NMX-J-519-ANCE, the third edition of CSA C22.2 No. 198.2, and the sixth edition of UL 486D. This edition of NMX-J-519-ANCE supersedes the previous edition published in 2006. This edition of CSA C22.2 No. 198.2 supersedes the previous edition published in 2005. This edition of UL 486D supersedes the previous edition published in 2005. This harmonized standard was prepared by the Association of Standardization and Certification (ANCE), CSA Group, and Underwriters Laboratories Inc. (UL). The efforts and support of the Technical Harmonization Committee for Connectors, THC 99, of the Council on the Harmonization of Electrotechnical Standards of the Nations of the Americas (CANENA), are gratefully acknowledged. This standard is considered suitable for use for conformity assessment within the stated scope of the standard. The present Mexican standard was developed by the SC 20D – Conectadores part of the CT 20 - Conductores from the Comite de Normalizacion de la Asociacion de Normalizacion y Certificacion, A.C., CONANCE, with the collaboration of the connectors manufacturers and users. This standard was reviewed by the CSA Subcommittee on C22.2 No. 198.2, under the jurisdiction of the CSA Technical Committee on Wiring Products and the CSA Strategic Steering Committee on Requirements for Electrical Safety, and has been formally approved by the CSA Technical Committee. This standard has been approved by the American National Standards Institute (ANSI) as an American National Standard. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 The requirements in this standard cover sealed wire connector systems, including insulating caps, covers, resins, tubing, and tapes provided with, or for use with, specific wire connectors. These systems are intended for wet or damp locations, and other installations such as direct burial, below grade, or above grade where protected from direct exposure to sunlight. The wire connectors covered by these requirements are intended for use with copper conductor, aluminum conductor, or both in accordance with installations covered by the National Electrical Code, NFPA 70; the Canadian Electrical Code, Part I, C22.1; and NOM 001 SEDE, Standard for Electrical Installations. Note 1: Unless marked for the purpose, these wire connector systems have not been evaluated for direct exposure to sunlight. Additional performance considerations to show equivalency to the connected conductors should be considered for UV exposure. Note 2: These wire connector systems have only been evaluated for fresh water unless marked for direct exposure to salt or seawater. Note 3: These wire connector systems may also be used indoors. 1.2 These requirements also cover sealed wire connector systems intended for use with single or multiple conductor underground feeder cable, golf course sprinkler cable, underground low energy cable, irrigation cable, or other cable with insulation acceptable for direct burial, below grade use, or wet locations. 1.3 These requirements apply to sealed wire connector systems intended for use with 30 AWG (0.05 mm2) through 2,000 kcmil (1,012 mm2) conductors with currents not exceeding the ampacity of insulated conductors rated either 75°C (167°F) or 90°C (194°F) and intended for use at 1500 V or less. 1.4 This standard does not apply to twist-on style splicing sealed wire connectors.600 V or less.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.