CSA C22.2 No. 601.1.3 : 1998

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

MEDICAL ELECTRICAL EQUIPMENT - GENERAL REQUIREMENTS FOR SAFETY -3 COLLATERAL STANDARD: GENERAL REQUIREMENTS FOR RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT

Available format(s)

Hardcopy , PDF

Superseded date

01-11-2009

Language(s)

English

Published date

01-01-2002

FOREWORD
INTRODUCTION
SECTION 1 : GENERAL
1 Scope, object and relationship to other standards
    1.201 Scope
    1.202 Object
    1.203 Relationship to other standards
2 Terminology and definitions
    2.201 Defined terms
    2.202 Qualifying conditions for defined terms
    2.203 Composition of reference materials
    2.204 Degrees of requirement and miscellaneous terms
    2.205 RADIATION QUANTITIES and units
4 General requirement for tests
    4.201 Compliance
6 Identification, marking and documents
    6.1 Marking on the outside of EQUIPMENT or EQUIPMENT parts
    6.8 ACCOMPANYING DOCUMENTS
SECTION 5 : PROTECTION AGAINST HAZARDS FROM UNWANTED
            UNWANTED OR EXCESSIVE RADIATION
29 X-RADIATION
29.201 RADIATION QUALITY
29.202 Limitation and indication of the extent of the X-RAY BEAM
29.203 Relationship between X-RAY FIELD and IMAGE RECEPTION AREA
29.204 LEAKAGE RADIATION
29.205 FOCAL SPOT TO SKIN DISTANCE
29.206 ATTENUATION of the X-RAY BEAM
29.207 PRIMARY PROTECTIVE SHIELDING
29.208 Protection against STRAY RADIATION
Annexes
AAA - Recommendation for the provision of information concerning
      STRAY RADIATION
BBB - Index of defined terms
CCC - Normative references to ACCOMPANYING DOCUMENTS, INSTRUCTIONS
      FOR USE and ASSEMBLING INSTRUCTIONS
Tables
201 - Subclauses containing requirements for marking
202 - Subclauses requiring statements in ACCOMPANYING DOCUMENTS
203 - Voltage restrictions in dental X-RAY EQUIPMENT
205 - Minimum FOCAL SPOT TO SKIN DISTANCES
206 - ATTENUATION EQUIVALENT of items in the X-RAY BEAM
207 - Parameters for testing ATTENUATION EQUIVALENT
208a- Application categories
208b- Requirements for PRIMARY PROTECTIVE SHIELDING
209 - STRAY RADIATION IN SIGNIFICANT ZONES OF OCCUPANCY
Figures
201 - Zone of EXTRA - FOCAL RADIATION
202 - Discrepancies in visual indication of the X-RAY FIELD
203 - Discrepancies in covering the IMAGE RECEPTION AREA
204 - Testing for STRAY RADIATION (undertable tube with X-RAY
      BEAM horizontal)
205 - Testing for STRAY RADIATION (overtable tube with X-RAY
      BEAM vertical)
206 - Testing for STRAY RADIATION (overtable tube with X-RAY
      BEAM horizontal)
207 - Testing for STRAY RADIATION (overtable with X-RAY BEAM
      vertical)
208 - Example of presentation of data on STRAY RADIATION

Aim is to protect against ionizing radiation in medical diagnostic X-ray equipment and its sub-assemblies to protect against ionizing radiation so that doses are kept as low as reasonably possible.

DocumentType
Standard
Pages
110
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy

Standards Relationship
IEC 60601-1-3:2008+AMD1:2013 CSV Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.