• CSA C22.2 No. 601.2.4 : 0

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    MEDICAL ELECTRICAL EQUIPMENT - PART 2: PARTICULAR REQUIREMENTS FOR THE SAFETY OF CARDIAC DEFIBRILLATORS AND CARDIAC DEFIBRILLATOR-MONITORS

    Available format(s):  Hardcopy, PDF

    Superseded date:  01-04-2004

    Language(s):  English

    Published date: 

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Technical Committee on Environmental Products
    Technical Committee on Medical Electrical Equipment
    Subcommittee on Cardiac Defibrillators
    CSA Preface
    CSA Foreword
    Glossary of Equivalent Terms
    Reference Publications
    Canadian Deviations
    IEC Standard 601-2-4 (1983)
    Foreword
    Preface
    SECTION ONE - GENERAL
    1 Scope and Object
    2 Terminology and Definitions
    3 General Requirements
    4 General Requirements for Tests
    5 Classification
    6 Identification, Marking and Documents
    7 Power Input
    SECTION TWO - SAFETY REQUIREMENTS
    SECTION THREE - PROTECTION AGAINST ELECTRIC SHOCK
    14 Requirements Related to Classification
    17 Insulation and PROTECTIVE IMPEDANCES
    19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY
       CURRENTS
    20 Dielectric Strength
    SECTION FOUR - PROTECTION AGAINST MECHANICAL HAZARDS
    SECTION FIVE - PROTECTION AGAINST HAZARDS FROM UNWANTED
                   OR EXCESSIVE RADIATION
    SECTION SIX - PROTECTION AGAINST HAZARDS OF EXPLOSIONS
                  IN MEDICALLY USED ROOMS
    SECTION SEVEN - PROTECTION AGAINST EXCESSIVE TEMPERATURES,
                    FIRE AND OTHER HAZARDS, SUCH AS HUMAN
                    ERRORS
    42 Excessive Temperatures
    44 Overflow, Spillage, Leakage, Humidity, Ingress of
       Liquids, Cleaning, Sterilization and Disinfection
    46 Human Errors
    SECTION EIGHT - ACCURACY OF OPERATING DATA AND PROTECTION
                    AGAINST INCORRECT OUTPUT
    50 Accuracy of Operating Data
    51 protection Against Incorrect Output
    SECTION NINE - FAULT CONDITIONS CAUSING OVERHEATING AND/OR
                   MECHANICAL DAMAGE; ENVIRONMENTAL TESTS
    SECTION TEN - CONSTRUCTIONAL REQUIREMENTS
    56 Components and General Assembly
    57 MAINS PARTS, Components and Layout
    SECTION 101 - ADDITIONAL REQUIREMENTS RELATING TO SAFETY
    101 Charging Time
    102 INTERNAL ELECTRICAL POWER SOURCE
    103 Endurance
    104 SYNCHRONIZER
    105 Recovery of the CARDIAC MONITOR after Defibrillation
    106 Disturbance of the CARDIAC MONITOR from Charging or
        Internal Discharging
    Figures 101 to 109
    APPENDIX B - Testing During Manufacturing and/or
                 Installation
    APPENDIX AA - Rationale

    Abstract - (Show below) - (Hide below)

    Defines requirements for the safety of CARDIAC DEFIBRILLATORS and CARDIAC DEFIBRILLATOR-MONITORS as defined in Sub-clauses 2.1.101 and 2.1.102, hereinafter referred to as EQUIPMENT, incorporating a capacitive energy storage device and which are designed to be installed and used in accordance with the Rules of the Canadian Electrical Code, Part I.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher Canadian Standards Association
    Status Superseded

    Standards Referencing This Book - (Show below) - (Hide below)

    C22.1-15 Canadian Electrical Code, Part I (23rd Edition), Safety Standard for Electrical Installations
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective