• There are no items in your cart

CSA C22.2 NO. 61010-2-051:19

Current

Current

The latest, up-to-date edition.

Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-051: Particular requirements for laboratory equipment for mixing and stirring (Adopted IEC 61010-2-051:2018, fourth edition, 2018-10, with Canadian deviations) | Exigences de sécurité pour appareils électriques de mesurage, de régulation, et de laboratoire — Partie 2-051 : Exigences particulières pour appareils de laboratoire utilisés pour mélanger et agiter (norme IEC 61010-2-051:2018 adoptée, quatrième édition, 2018-10, avec exigences propres au Canada)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

01-01-2019

€48.46
Excluding VAT

CSA Preface This is the fourth edition of CSA C22.2 No. 61010-2-051, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-051: Particular requirements for laboratory equipment for mixing and stirring, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-051 (fourth edition, 2018-10). It supersedes the previous edition published in 2015 as CAN/CSA-C22.2 No. 61010-2-051 (adopted IEC 61010-2-051:2015). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as \"CSA C22.2 No. 61010-2-051\" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian and US deviations); and Amendment 1:2018 to CAN/CSA-C22.2 No. 61010-1:12 (adopted IEC Amendment 1:2016, with Canadian and US deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the text, except the first paragraph, with the following new text: This part of IEC 61010 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices can contain heating elements. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of the IEC 61010 series as well as within the scope of this document, consideration is given to those other Part 2 standards. The standard for equipment which contains heating devices is IEC 61010-2-010. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la quatrième édition de CSA C22.2 nº 61010-2-051, Exigences de sécurité pour appareils électriques de mesurage, de régulation, et de laboratoire — Partie 2-051 : Exigences particulières pour appareils de laboratoire utilisés pour mélanger et agiter. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-051 (quatrième édition, 2018-10), qui porte le même titre. Il remplace l\'édition antérieure publiée en 2015 qui portait la désignation CAN/CSA-C22.2 nº 61010-2-051 (norme IEC 61010-2-051:2015 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CSA C22.2 nº 61010-2-051 ». Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada et aux États-Unis); et Modification 1:2018 à CAN/CSA-C22.2 nº 61010-1:12 (IEC Amendement 1:2016 adopté, avec exigences propres au Canada et aux États-Unis). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application et objet L’article de la Partie 1 est applicable à l’exception de ce qui suit: 1.1.1 Appareils inclus dans le domaine d’application Remplacement: Remplacer le texte, excepté le premier alinéa, par le nouveau texte suivant: La présente partie de l’IEC 61010 est applicable aux appareils de laboratoire électriques et à leurs accessoires, destinés à mélanger et à agiter, et qui, par l’énergie mécanique dispensée, modifient la forme, la taille ou l’homogénéité des matériaux et de leurs accessoires. De tels appareils peuvent contenir des éléments de chauffage. NOTE Si une ou toutes les parties de l’appareil relèvent du domaine d’application d’une ou plusieurs autres Parties 2 de la série IEC 61010, ainsi que du domaine d’application du présent document, ces autres Parties 2 sont prises en compte. La norme relative aux appareils qui contiennent des dispositifs de chauffage est l’IEC 61010-2-010.

DocumentType
Standard
ISBN
978-1-4883-2445-1
Pages
48
ProductNote
THIS STANDARD ALSO REFERS - CAN/CSA-C22.2 No. 0-10 (R2015),CAN/CSA-C22.2 No. 61010-1:12 (R2017)
PublisherName
Canadian Standards Association
Status
Current

CSA Preface This is the fourth edition of CSA C22.2 No. 61010-2-051, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-051: Particular requirements for laboratory equipment for mixing and stirring, which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 61010-2-051 (fourth edition, 2018-10). It supersedes the previous edition published in 2015 as CAN/CSA-C22.2 No. 61010-2-051 (adopted IEC 61010-2-051:2015). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. For brevity, this Standard will be referred to as \"CSA C22.2 No. 61010-2-051\" throughout. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 61010-1:12, Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements (adopted IEC 61010-1:2010, with Canadian and US deviations); and Amendment 1:2018 to CAN/CSA-C22.2 No. 61010-1:12 (adopted IEC Amendment 1:2016, with Canadian and US deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object This clause of Part 1 is applicable except as follows: 1.1.1 Equipment included in scope Replacement: Replace the text, except the first paragraph, with the following new text: This part of IEC 61010 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices can contain heating elements. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of the IEC 61010 series as well as within the scope of this document, consideration is given to those other Part 2 standards. The standard for equipment which contains heating devices is IEC 61010-2-010. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la quatrième édition de CSA C22.2 nº 61010-2-051, Exigences de sécurité pour appareils électriques de mesurage, de régulation, et de laboratoire — Partie 2-051 : Exigences particulières pour appareils de laboratoire utilisés pour mélanger et agiter. Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 61010-2-051 (quatrième édition, 2018-10), qui porte le même titre. Il remplace l\'édition antérieure publiée en 2015 qui portait la désignation CAN/CSA-C22.2 nº 61010-2-051 (norme IEC 61010-2-051:2015 adoptée). Il fait partie d’une série de normes publiées par Groupe CSA qui constituent le Code canadien de l’électricité, Deuxième partie. Par souci de brièveté, tout au long de ce document, il sera appelé « CSA C22.2 nº 61010-2-051 ». Cette norme est conçue pour être utilisée de concert avec CAN/CSA-C22.2 nº 61010-1:12, Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire — Partie 1 : Exigences générales (norme IEC 61010-1:2010 adoptée, avec exigences propres au Canada et aux États-Unis); et Modification 1:2018 à CAN/CSA-C22.2 nº 61010-1:12 (IEC Amendement 1:2016 adopté, avec exigences propres au Canada et aux États-Unis). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application et objet L’article de la Partie 1 est applicable à l’exception de ce qui suit: 1.1.1 Appareils inclus dans le domaine d’application Remplacement: Remplacer le texte, excepté le premier alinéa, par le nouveau texte suivant: La présente partie de l’IEC 61010 est applicable aux appareils de laboratoire électriques et à leurs accessoires, destinés à mélanger et à agiter, et qui, par l’énergie mécanique dispensée, modifient la forme, la taille ou l’homogénéité des matériaux et de leurs accessoires. De tels appareils peuvent contenir des éléments de chauffage. NOTE Si une ou toutes les parties de l’appareil relèvent du domaine d’application d’une ou plusieurs autres Parties 2 de la série IEC 61010, ainsi que du domaine d’application du présent document, ces autres Parties 2 sont prises en compte. La norme relative aux appareils qui contiennent des dispositifs de chauffage est l’IEC 61010-2-010.

Standards Relationship
IEC 61010-2-051:2018 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.