• CSA C50052 : 1999 : INC : UPD 1 : 1999 : R2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    CAST ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR

    Available format(s):  Hardcopy, PDF

    Superseded date:  23-07-2013

    Language(s):  English

    Published date:  01-01-2016

    Publisher:  Canadian Standards Association

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    0 Introduction
    1 Scope
    2 Quality assurance
    3 Definitions
    4 Materials
       4.1 Selection of material
       4.2 Chemical analysis
    5 Design
       5.1 General
       5.2 Corrosion allowance
       5.3 Design stresses
       5.4 Calculation methods
       5.5 Manholes and inspection openings
    6 Manufacture and workmanship
       6.1 Manufacture
       6.2 Consultation between manufacturer and founder
       6.3 Foundry technique
       6.4 Geometry and dimensions
       6.5 Chemical composition and mechanical properties
       6.6 Workmanship
    7 Repair of casting defects
       7.1 General
       7.2 Repair by welding
       7.3 Impregnation of castings
    8 Heat treatment
       8.1 Heat treatment procedure
       8.2 Methods of heating
       8.3 Quenching
       8.4 Calibration of furnace temperature
       8.5 Heat treatment charts
    9 Inspection, testing and certification
       9.1 Proof tests
       9.2 Inspection and routine tests
       9.3 Certification
    10 Pressure relief devices
       10.1 General
       10.2 Bursting discs
       10.3 Self-closing pressure relief valves
       10.4 Non-self-closing pressure relief devices
    Table
    Figure
    Annex
    A Welder performance test

    Abstract - (Show below) - (Hide below)

    Applicable to cast aluminium alloy enclosures pressurized with dry air, inert gases, for example, sulphur hexafluoride, carbon tetrafluoride, or nitrogen or a mixtures of these gases, used in indoor or outdoor installations of high-voltage switchgear and control gear, where the gas is used principally for its dielectric and/or arc-quenching properties, with rated voltages: (a) 1 kV and up to and including 52 kV and with gas-filled compartments with design pressure greater than 3 bar (gauge); and (b) 72.5 kV and above. Also covers pressurized components such as the centre chamber of live tank switchgear, gas-insulated current transformers, etc.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Product Note Reconfirmed EN
    Publisher Canadian Standards Association
    Status Superseded
    Superseded By
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective