• There are no items in your cart

CSA E60730-2-14:20

Current

Current

The latest, up-to-date edition.

Automatic electrical controls — Part 2-14: Particular requirements for electric actuators (Adopted IEC 60730-2-14:2017, edition 2:2017 consolidated with amendment 1:2019, with Canadian deviations) | Dispositifs de commande électrique automatiques — Partie 2-14 : Exigences particulières pour les actionneurs électriques (norme IEC 60730-2-14:2017 adoptée, édition 2:2017 consolidée par l’amendement 1:2019, avec exigences propres au Canada)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

01-01-2020

CSA Preface This is the second edition of CSA E60730-2-14, Automatic electrical controls — Part 2-14: Particular requirements for electric actuators , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-14 (edition 2:2017 consolidated with Amendment 1:2019). It supersedes the previous edition, published in 2013 as CAN/CSA-E60730-2-14 (adopted IEC 60730-2-14:1995+A1:2001+A2:2007). This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:15, Automatic electrical controls — Part 1: General requirements (adopted IEC 60730-1:2013, with Canadian deviations); and Amendment 1:2017 to CAN/CSA-E60730-1:15 (adopted IEC Amendment 1:2015, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This clause of Part 1 is applicable except as follows: 1.1 Replacement: This part 2-14 applies to electric actuators for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. NOTE Throughout this standard the word \"equipment\" means \"appliance and equipment.\" EXAMPLE 1 Electric actuators for appliances within the scope of IEC 60335. This International Standard is applicable to controls for building automation within the scope of ISO 16484. This part 2-14 also applies to automatic electrical controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. EXAMPLE 2 Controls for commercial catering, heating and air-conditioning equipment. This part 2-14 is also applicable to individual electric actuators utilized as part of a control system or controls, which are mechanically integral with multifunctional controls having non-electrical outputs. EXAMPLE 3 Independently mounted water valves, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2. This part 2-14 does not apply to automatic electric actuators intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. This part 2-14 applies to electric actuators powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. 1.1.1 This part 2-14 applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of electric actuators used in or in association with equipment. NOTE Requirements for specific operating values, operating times and operating sequences may be given in the standards for appliances and equipment. This standard is also applicable to the functional safety of low complexity safety related systems and controls. This part 2-14 does not apply to electric actuators which are mechanically integrated with valves covered by a separate part 2, e.g. IEC 60730-2-8. This part 2-14 does not apply to electric motors, requirements for which are contained in IEC 60034. 1.1.2 Requirements for manual switches not integral with an electric actuator are contained in IEC 61058-1. 1.1.3 Replacement This part 2-14 applies to a.c. or d.c. powered electric actuators with a rated voltage not exceeding 690 V a.c. or 600 V d.c. 1.1.4 Replacement This part 2-14 does not take into account the response value of an automatic action of an electric actuator, if such a response value is dependent upon the method of mounting the electric actuator in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment or as determined by the manufacturer shall apply. 1.1.5 Void. 1.1.6 Void. 1.1.7 Replacement: This part 2-14 applies also to electric actuators incorporating electronic devices, requirements for which are contained in Annex H. 1.1.8 Replacement: This part 2-14 applies also to electric actuators using NTC or PTC thermistors, requirements for which are contained in Annex J. 1.1.9 Replacement: This part 2-14 applies to the electrical and functional safety of electric actuators capable of receiving and responding to communications signals, including signals for power billing rate and demand response. The signals may be transmitted to or received from external units being part of the electric actuator (wired), or to and from external units, which are not part of the electric actuator (wireless) under test. 1.1.10 Replacement: This part 2-14 does not address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de CSA E60730-2-14, Dispositifs de commande électrique automatiques — Partie 2-14 : Exigences particulières pour les actionneurs électriques . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60730-2-14 (édition 2:2017 consolidée par l’amendement 1:2019), qui porte le même titre. Il remplace l’édition antérieure publiée en 2013 qui portait la désignation CAN/CSA-E60730-2-14 (norme IEC 60730-2-14:1995+A1:2001+A2:2007 adoptée). Cette norme est conçue pour être utilisée de concert avec CAN/CSA-E60730-1:15, Dispositifs de commande électrique automatiques — Partie 1 : Exigences générales (norme IEC 60730-1:2013 adoptée, avec exigences propres au Canada); et Modification 1:2017 à CAN/CSA-E60730-1:15 (IEC Amendement 1:2015 adopté, avec exigences propres au Canada). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application L\'article de la Partie 1 s\'applique avec les exceptions suivantes: 1.1 Remplacement: La présente partie 2-14 s\'applique aux actionneurs électriques utilisés dans, sur ou avec les matériels pour usage domestique et analogue. Le matériel peut utiliser l\'électricité, le gaz, le pétrole, des combustibles solides, l\'énergie thermique solaire, etc. ou une combinaison de ces sources d\'énergie. NOTE Dans la présente norme, le terme «matériel» signifie «appareil et matériel». EXEMPLE 1 Actionneurs électriques pour appareils relevant du domaine d’application de l’IEC 60335. La présente Norme internationale s’applique aux dispositifs de commande pour l’automatisation du bâtiment relevant du domaine d’application de l’ISO 16484. La présente partie 2-14 s’applique également aux dispositifs de commande électrique automatiques des matériels qui peuvent être utilisés par le public tels que les matériels destinés à être utilisés dans des magasins, des bureaux, des hôpitaux, des fermes et des applications commerciales et industrielles. EXEMPLE 2 Dispositifs de commande pour les installations de restauration, de chauffage et d’air conditionné. La présente partie 2-14 est applicable également aux actionneurs électriques individuels utilisés comme partie d’un système de commande ou de dispositifs de commande solidaire mécaniquement de dispositifs de commande multifonctions ayant des sorties non électriques. EXEMPLE 3 Les vannes hydrauliques montées indépendamment, les dispositifs de commande des systèmes de réseau électrique intelligent et les dispositifs de commande des systèmes d’automatisation des bâtiments relevant du domaine d’application de l’ISO 16484-2. La présente partie 2-14 ne s’applique pas aux actionneurs électriques automatiques prévus exclusivement pour des applications industrielles, sauf mention particulière dans la partie 2 applicable ou la norme du matériel. La présente partie 2-14 s\'applique aux actionneurs électriques alimentés par des piles primaires ou secondaires, les exigences qui les concernent étant contenues dans la norme, y compris dans l\'Annexe V. 1.1.1 La présente partie 2-14 s\'applique à la sécurité intrinsèque, aux valeurs de fonctionnement, aux temps de fonctionnement et aux séquences de fonctionnement dans la mesure où ils interviennent dans la sécurité du matériel, ainsi qu\'aux essais des actionneurs électriques utilisés dans, ou avec le matériel. NOTE Des exigences relatives à des valeurs de fonctionnement, temps de fonctionnement et séquences de fonctionnement spécifiques peuvent être données dans les normes relatives aux appareils et matériels. La présente norme s’applique également aux systèmes et dispositifs de commande de sécurité fonctionnelle et de sécurité peu complexe. La présente partie 2-14 ne s\'applique pas aux actionneurs électriques qui sont mécaniquement intégrés dans des vannes, couverts par une partie 2 distincte, par exemple l’IEC 60730-2-8. La présente partie 2-14 ne s\'applique pas aux moteurs électriques dont les exigences font l\'objet de l’IEC 60034. 1.1.2 Les exigences relatives aux interrupteurs manuels ne faisant pas partie d\'un actionneur électrique sont contenues dans l’IEC 61058-1. 1.1.3 Remplacement La présente partie 2-14 s\'applique aux actionneurs électriques à courant alternatif ou continu dont la tension assignée ne dépasse pas 690 V en courant alternatif et 600 V en courant continu. 1.1.4 Remplacement La présente partie 2-14 ne prend pas en considération la valeur de réponse d\'une action automatique d\'un actionneur électrique lorsque cette valeur de réponse est influencée par la méthode de montage de l\'actionneur électrique dans le matériel. Lorsqu\'une valeur de réponse est importante du point de vue de la protection de l\'utilisateur ou de l\'environnement, la valeur spécifiée dans le matériel domestique approprié ou déterminée par le fabricant doit s\'appliquer. 1.1.5 Vacant. 1.1.6 Vacant. 1.1.7 Remplacement: La présente partie 2-14 s\'applique également aux actionneurs électriques incorporant des dispositifs électroniques, dont les exigences sont données à l\'Annexe H. 1.1.8 Remplacement: La présente partie 2-14 s\'applique également aux actionneurs électriques utilisant des thermistances CTN ou CTP, dont les exigences sont données à l\'Annexe J. 1.1.9 Remplacement: La présente partie 2-14 s\'applique à la sécurité électrique et fonctionnelle des actionneurs électriques capables de recevoir et de répondre à des signaux de communication, y compris les signaux propres au taux de facturation de l’électricité et à la gestion de la demande. Les signaux peuvent être transmis à des unités externes ou reçus de telles unités qui font partie intégrante de l\'actionneur électrique (câblé), ou vers et depuis des unités externes qui ne font pas partie intégrante de l\'actionneur électrique (non câblé) en essai. 1.1.10 Remplacement: La présente partie 2-14 ne traite pas de l\'intégrité du signal de sortie transmis aux dispositifs de réseau, comme l’interopérabilité avec d’autres dispositifs, à moins qu’elle n’ait été évaluée comme partie intégrante du système de commande.

CSA Preface This is the second edition of CSA E60730-2-14, Automatic electrical controls — Part 2-14: Particular requirements for electric actuators , which is an adoption, with Canadian deviations, of the identically titled IEC (International Electrotechnical Commission) Standard 60730-2-14 (edition 2:2017 consolidated with Amendment 1:2019). It supersedes the previous edition, published in 2013 as CAN/CSA-E60730-2-14 (adopted IEC 60730-2-14:1995+A1:2001+A2:2007). This Standard is intended to be used in conjunction with CAN/CSA-E60730-1:15, Automatic electrical controls — Part 1: General requirements (adopted IEC 60730-1:2013, with Canadian deviations); and Amendment 1:2017 to CAN/CSA-E60730-1:15 (adopted IEC Amendment 1:2015, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This clause of Part 1 is applicable except as follows: 1.1 Replacement: This part 2-14 applies to electric actuators for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. NOTE Throughout this standard the word \"equipment\" means \"appliance and equipment.\" EXAMPLE 1 Electric actuators for appliances within the scope of IEC 60335. This International Standard is applicable to controls for building automation within the scope of ISO 16484. This part 2-14 also applies to automatic electrical controls for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. EXAMPLE 2 Controls for commercial catering, heating and air-conditioning equipment. This part 2-14 is also applicable to individual electric actuators utilized as part of a control system or controls, which are mechanically integral with multifunctional controls having non-electrical outputs. EXAMPLE 3 Independently mounted water valves, controls in smart grid systems and controls for building automation systems within the scope of ISO 16484-2. This part 2-14 does not apply to automatic electric actuators intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. This part 2-14 applies to electric actuators powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. 1.1.1 This part 2-14 applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of electric actuators used in or in association with equipment. NOTE Requirements for specific operating values, operating times and operating sequences may be given in the standards for appliances and equipment. This standard is also applicable to the functional safety of low complexity safety related systems and controls. This part 2-14 does not apply to electric actuators which are mechanically integrated with valves covered by a separate part 2, e.g. IEC 60730-2-8. This part 2-14 does not apply to electric motors, requirements for which are contained in IEC 60034. 1.1.2 Requirements for manual switches not integral with an electric actuator are contained in IEC 61058-1. 1.1.3 Replacement This part 2-14 applies to a.c. or d.c. powered electric actuators with a rated voltage not exceeding 690 V a.c. or 600 V d.c. 1.1.4 Replacement This part 2-14 does not take into account the response value of an automatic action of an electric actuator, if such a response value is dependent upon the method of mounting the electric actuator in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment or as determined by the manufacturer shall apply. 1.1.5 Void. 1.1.6 Void. 1.1.7 Replacement: This part 2-14 applies also to electric actuators incorporating electronic devices, requirements for which are contained in Annex H. 1.1.8 Replacement: This part 2-14 applies also to electric actuators using NTC or PTC thermistors, requirements for which are contained in Annex J. 1.1.9 Replacement: This part 2-14 applies to the electrical and functional safety of electric actuators capable of receiving and responding to communications signals, including signals for power billing rate and demand response. The signals may be transmitted to or received from external units being part of the electric actuator (wired), or to and from external units, which are not part of the electric actuator (wireless) under test. 1.1.10 Replacement: This part 2-14 does not address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de CSA E60730-2-14, Dispositifs de commande électrique automatiques — Partie 2-14 : Exigences particulières pour les actionneurs électriques . Il s’agit de l’adoption, avec exigences propres au Canada, de la norme IEC (Commission Électrotechnique Internationale) 60730-2-14 (édition 2:2017 consolidée par l’amendement 1:2019), qui porte le même titre. Il remplace l’édition antérieure publiée en 2013 qui portait la désignation CAN/CSA-E60730-2-14 (norme IEC 60730-2-14:1995+A1:2001+A2:2007 adoptée). Cette norme est conçue pour être utilisée de concert avec CAN/CSA-E60730-1:15, Dispositifs de commande électrique automatiques — Partie 1 : Exigences générales (norme IEC 60730-1:2013 adoptée, avec exigences propres au Canada); et Modification 1:2017 à CAN/CSA-E60730-1:15 (IEC Amendement 1:2015 adopté, avec exigences propres au Canada). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application L\'article de la Partie 1 s\'applique avec les exceptions suivantes: 1.1 Remplacement: La présente partie 2-14 s\'applique aux actionneurs électriques utilisés dans, sur ou avec les matériels pour usage domestique et analogue. Le matériel peut utiliser l\'électricité, le gaz, le pétrole, des combustibles solides, l\'énergie thermique solaire, etc. ou une combinaison de ces sources d\'énergie. NOTE Dans la présente norme, le terme «matériel» signifie «appareil et matériel». EXEMPLE 1 Actionneurs électriques pour appareils relevant du domaine d’application de l’IEC 60335. La présente Norme internationale s’applique aux dispositifs de commande pour l’automatisation du bâtiment relevant du domaine d’application de l’ISO 16484. La présente partie 2-14 s’applique également aux dispositifs de commande électrique automatiques des matériels qui peuvent être utilisés par le public tels que les matériels destinés à être utilisés dans des magasins, des bureaux, des hôpitaux, des fermes et des applications commerciales et industrielles. EXEMPLE 2 Dispositifs de commande pour les installations de restauration, de chauffage et d’air conditionné. La présente partie 2-14 est applicable également aux actionneurs électriques individuels utilisés comme partie d’un système de commande ou de dispositifs de commande solidaire mécaniquement de dispositifs de commande multifonctions ayant des sorties non électriques. EXEMPLE 3 Les vannes hydrauliques montées indépendamment, les dispositifs de commande des systèmes de réseau électrique intelligent et les dispositifs de commande des systèmes d’automatisation des bâtiments relevant du domaine d’application de l’ISO 16484-2. La présente partie 2-14 ne s’applique pas aux actionneurs électriques automatiques prévus exclusivement pour des applications industrielles, sauf mention particulière dans la partie 2 applicable ou la norme du matériel. La présente partie 2-14 s\'applique aux actionneurs électriques alimentés par des piles primaires ou secondaires, les exigences qui les concernent étant contenues dans la norme, y compris dans l\'Annexe V. 1.1.1 La présente partie 2-14 s\'applique à la sécurité intrinsèque, aux valeurs de fonctionnement, aux temps de fonctionnement et aux séquences de fonctionnement dans la mesure où ils interviennent dans la sécurité du matériel, ainsi qu\'aux essais des actionneurs électriques utilisés dans, ou avec le matériel. NOTE Des exigences relatives à des valeurs de fonctionnement, temps de fonctionnement et séquences de fonctionnement spécifiques peuvent être données dans les normes relatives aux appareils et matériels. La présente norme s’applique également aux systèmes et dispositifs de commande de sécurité fonctionnelle et de sécurité peu complexe. La présente partie 2-14 ne s\'applique pas aux actionneurs électriques qui sont mécaniquement intégrés dans des vannes, couverts par une partie 2 distincte, par exemple l’IEC 60730-2-8. La présente partie 2-14 ne s\'applique pas aux moteurs électriques dont les exigences font l\'objet de l’IEC 60034. 1.1.2 Les exigences relatives aux interrupteurs manuels ne faisant pas partie d\'un actionneur électrique sont contenues dans l’IEC 61058-1. 1.1.3 Remplacement La présente partie 2-14 s\'applique aux actionneurs électriques à courant alternatif ou continu dont la tension assignée ne dépasse pas 690 V en courant alternatif et 600 V en courant continu. 1.1.4 Remplacement La présente partie 2-14 ne prend pas en considération la valeur de réponse d\'une action automatique d\'un actionneur électrique lorsque cette valeur de réponse est influencée par la méthode de montage de l\'actionneur électrique dans le matériel. Lorsqu\'une valeur de réponse est importante du point de vue de la protection de l\'utilisateur ou de l\'environnement, la valeur spécifiée dans le matériel domestique approprié ou déterminée par le fabricant doit s\'appliquer. 1.1.5 Vacant. 1.1.6 Vacant. 1.1.7 Remplacement: La présente partie 2-14 s\'applique également aux actionneurs électriques incorporant des dispositifs électroniques, dont les exigences sont données à l\'Annexe H. 1.1.8 Remplacement: La présente partie 2-14 s\'applique également aux actionneurs électriques utilisant des thermistances CTN ou CTP, dont les exigences sont données à l\'Annexe J. 1.1.9 Remplacement: La présente partie 2-14 s\'applique à la sécurité électrique et fonctionnelle des actionneurs électriques capables de recevoir et de répondre à des signaux de communication, y compris les signaux propres au taux de facturation de l’électricité et à la gestion de la demande. Les signaux peuvent être transmis à des unités externes ou reçus de telles unités qui font partie intégrante de l\'actionneur électrique (câblé), ou vers et depuis des unités externes qui ne font pas partie intégrante de l\'actionneur électrique (non câblé) en essai. 1.1.10 Remplacement: La présente partie 2-14 ne traite pas de l\'intégrité du signal de sortie transmis aux dispositifs de réseau, comme l’interopérabilité avec d’autres dispositifs, à moins qu’elle n’ait été évaluée comme partie intégrante du système de commande.

DocumentType
Standard
ISBN
978-1-4883-2982-1
Pages
137
ProductNote
THIS STANDARD ALSO REFERS TO CAN/CSA-C22.2 No. 0.17-00 (R2018),CAN/CSA-C22.2 No. 61058-1:17 ,IEC 60730-2-8:2000
PublisherName
Canadian Standards Association
Status
Current
Supersedes

View more information
€284.57
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.