CSA IEC 61000-4-15:12 (R2021)
Current
The latest, up-to-date edition.
Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications (Adopted IEC 61000-4-15:2010, edition 2.0, 2010-08) | Compatibilité électromagnétique (CEM) - Partie 4-15 : Techniques d\'essai et de mesure - Flickermètre - Spécifications fonctionnelles et de conception (norme IEC 61000-4-15:2010 adoptée, édition 2.0, 2010-08)
Hardcopy , PDF
English - French
01-01-2012
CSA Preface This is the second edition of CAN/CSA-IEC 61000-4-15, Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61000-4-15 (second edition, 2010-08). It supersedes the previous edition, published in 2003 as CAN/CSA-CEI/IEC 61000-4-15 (adopted IEC 61000-4-15:1997+A1:2003). This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Low Frequency EMC, under the jurisdiction of the CSA Technical Committee on Electromagnetic Compatibility and the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope and object This part of IEC 61000 gives a functional and design specification for flicker measuring apparatus intended to indicate the correct flicker perception level for all practical voltage fluctuation waveforms. Information is presented to enable such an instrument to be constructed. A method is given for the evaluation of flicker severity on the basis of the output of flickermeters complying with this standard. The flickermeter specifications in this part of IEC 61000 relate only to measurements of 120 V and 230 V, 50 Hz and 60 Hz inputs. Characteristics of some incandescent lamps for other voltages are sufficiently similar to the values in Table 1 and Table 2, that the use of a correction factor can be applied for those other voltages. Some of these correction factors are provided in the Annex B. Detailed specifications for voltages and frequencies other than those given above, remain under consideration. The object of this part of IEC 61000 is to provide basic information for the design and the instrumentation of an analogue or digital flicker measuring apparatus. It does not give tolerance limit values of flicker severity. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-IEC 61000-4-15:12, Compatibilité électromagnétique (CEM) - Partie 4-15 : Techniques d\'essai et de mesure - Flickermètre - Spécifications fonctionnelles et de conception . Il s\'agit de l\'adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 61000-4-15 (deuxième édition, 2010-08) qui porte le même titre. Cette norme a été révisée en vue de son adoption pour le Canada par le Sous-comité technique CSA sur la CÉM à basse fréquence, sous l’autorité du Comité technique CSA sur la compatibilité électromagnétique et du Comité directeur stratégique CSA sur le génie en matière d’énergie et la compatibilité électromagnétique, et a été approuvée par le Comité technique. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d\'application et objet La présente partie de la CEI 61000 traite des spécifications fonctionnelles et de conception d\'un appareil mesurant le flicker, destiné à indiquer le niveau correct de perception du flicker du flux lumineux (le flicker) pour toutes les formes d\'ondes de fluctuation de la tension rencontrées dans la pratique. On y présente des informations permettant de construire un tel instrument. Une méthode d\'évaluation de la sévérité du flicker est fournie à partir des résultats obtenus avec des flickermètres en conformité avec cette norme. Les spécifications du flickermètre dans cette partie concernent uniquement les mesures des entrées de 120 V et 230 V, 50 Hz et 60 Hz. Les caractéristiques de certaines lampes à incandescence pour d\'autres tensions sont suffisamment similaires aux valeurs des Tableaux 1 et 2 pour que l\'utilisation d\'un facteur de correction puisse être appliquée à ces autres tensions. Certains de ces facteurs de correction sont fournis à l\'Annexe B. Des spécifications détaillées pour des tensions et des fréquences autres que celles données ci-dessus sont à l\'étude. L\'objet de la présente partie de la CEI 61000 est de fournir les informations nécessaires à la conception et à la réalisation d\'un flickermètre analogique ou numérique. Elle ne spécifie pas les valeurs limites tolérables du flicker.
DocumentType |
Standard
|
ISBN |
978-1-55491-959-8
|
Pages |
107
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
CSA Preface This is the second edition of CAN/CSA-IEC 61000-4-15, Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61000-4-15 (second edition, 2010-08). It supersedes the previous edition, published in 2003 as CAN/CSA-CEI/IEC 61000-4-15 (adopted IEC 61000-4-15:1997+A1:2003). This Standard was reviewed for Canadian adoption by the CSA Subcommittee on Low Frequency EMC, under the jurisdiction of the CSA Technical Committee on Electromagnetic Compatibility and the CSA Strategic Steering Committee on Power Engineering and Electromagnetic Compatibility, and has been formally approved by the Technical Committee. This Standard has been approved as a National Standard of Canada by the Standards Council of Canada. Scope and object This part of IEC 61000 gives a functional and design specification for flicker measuring apparatus intended to indicate the correct flicker perception level for all practical voltage fluctuation waveforms. Information is presented to enable such an instrument to be constructed. A method is given for the evaluation of flicker severity on the basis of the output of flickermeters complying with this standard. The flickermeter specifications in this part of IEC 61000 relate only to measurements of 120 V and 230 V, 50 Hz and 60 Hz inputs. Characteristics of some incandescent lamps for other voltages are sufficiently similar to the values in Table 1 and Table 2, that the use of a correction factor can be applied for those other voltages. Some of these correction factors are provided in the Annex B. Detailed specifications for voltages and frequencies other than those given above, remain under consideration. The object of this part of IEC 61000 is to provide basic information for the design and the instrumentation of an analogue or digital flicker measuring apparatus. It does not give tolerance limit values of flicker severity. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de la CAN/CSA-IEC 61000-4-15:12, Compatibilité électromagnétique (CEM) - Partie 4-15 : Techniques d\'essai et de mesure - Flickermètre - Spécifications fonctionnelles et de conception . Il s\'agit de l\'adoption, sans modifications, de la norme CEI (Commission Électrotechnique Internationale) 61000-4-15 (deuxième édition, 2010-08) qui porte le même titre. Cette norme a été révisée en vue de son adoption pour le Canada par le Sous-comité technique CSA sur la CÉM à basse fréquence, sous l’autorité du Comité technique CSA sur la compatibilité électromagnétique et du Comité directeur stratégique CSA sur le génie en matière d’énergie et la compatibilité électromagnétique, et a été approuvée par le Comité technique. Cette norme a été approuvée en tant que Norme nationale du Canada par le Conseil canadien des normes. Domaine d\'application et objet La présente partie de la CEI 61000 traite des spécifications fonctionnelles et de conception d\'un appareil mesurant le flicker, destiné à indiquer le niveau correct de perception du flicker du flux lumineux (le flicker) pour toutes les formes d\'ondes de fluctuation de la tension rencontrées dans la pratique. On y présente des informations permettant de construire un tel instrument. Une méthode d\'évaluation de la sévérité du flicker est fournie à partir des résultats obtenus avec des flickermètres en conformité avec cette norme. Les spécifications du flickermètre dans cette partie concernent uniquement les mesures des entrées de 120 V et 230 V, 50 Hz et 60 Hz. Les caractéristiques de certaines lampes à incandescence pour d\'autres tensions sont suffisamment similaires aux valeurs des Tableaux 1 et 2 pour que l\'utilisation d\'un facteur de correction puisse être appliquée à ces autres tensions. Certains de ces facteurs de correction sont fournis à l\'Annexe B. Des spécifications détaillées pour des tensions et des fréquences autres que celles données ci-dessus sont à l\'étude. L\'objet de la présente partie de la CEI 61000 est de fournir les informations nécessaires à la conception et à la réalisation d\'un flickermètre analogique ou numérique. Elle ne spécifie pas les valeurs limites tolérables du flicker.
Standards | Relationship |
IEC 61000-4-15:2010 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.