• Shopping Cart
    There are no items in your cart

CSA IEC 61000-4-9:02 (R2020)

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Electromagnetic compatibility (EMC) — Part 4-9: Testing and measurement techniques — Pulse magnetic field immunity test(Adopted CEI/IEC 61000-4-9:1993 + A1:2000, edition 1.1, 2001-03) | Compatibilité électromagnétique (CEM) - Partie 4-9: Techniques d\'essai et de mesure - Essai d\'immunité au champ magnétique impulsionnel (norme CEI/IEC 61000-4-9:1993 + A1:2000 adoptée, edition 1.1, 2001-03)

Available format(s)

Hardcopy , PDF

Withdrawn date

12-08-2022

Language(s)

English - French

Published date

01-01-2002

€82.85
Excluding VAT

This international standard relates to the immunity requirements of equipment, only under operational conditions, to pulse magnetic disturbances mainly related to: ñ industrial installations and power plants; ñ medium voltage and high voltage sub-stations.

DocumentType
Standard
ISBN
1-55324-864-3
Pages
83
PublisherName
Canadian Standards Association
Status
Withdrawn
Supersedes

CSA Preface This is the first edition of CSA Standard CAN/CSA-CEI/IEC 61000-4-9, Electromagnetic compatibility (EMC) — Part 4-9: Testing and measurement techniques — Pulse magnetic field immunity test , which is an adoption without modification of the identically titled CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) Standard 61000-4-9:1993+A1:2000 (edition 1:1993 consolidated with amendment 1:2000). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope This international standard relates to the immunity requirements of equipment, only under operational conditions, to pulse magnetic disturbances mainly related to: - industrial installations and power plants; - medium voltage and high voltage sub-stations. The applicability of this standard to equipment installed in different locations is determined by the presence of the phenomenon, as specified in clause 3. This standard does not consider disturbances due to capacitive or inductive coupling in cables or other parts of the field installation. Other IEC standards dealing with conducted disturbances cover these aspects. The object of this standard is to establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment for household, commercial and industrial applications when subjected to pulse magnetic fields. The standard defines: - recommended test levels; - test equipment; - test set-up; - test procedure. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la première édition de la norme CAN/CSA-CEI/IEC 61000-4-9, Compatibilité électromagnétique (CEM) — Partie 4-9 : Techniques d’essai et de mesure — Essai d’immunité au champ magnétique impulsionnel . Il s’agit de l’adoption, sans modifications, de la norme CEI/IEC (Commission Électrotechnique Internationale/International Electrotechnical Commission) 61000-4-9:1993+A1:2000 (édition 1:1993 consolidée par l’amendement 1:2000), qui porte le même titre. Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d\'application La présente norme internationale traite des exigences en matière d\'immunité des matériels uniquement dans les conditions d\'utilisation, contre les perturbations magnétiques impulsion-nelles principalement dans les: - installations industrielles et les centrales électriques; - postes moyenne et haute tension. Les conditions d\'application de la présente norme aux matériels installés dans les différents secteurs sont déterminées par la présence du phénomène dans les conditions spécifiées dans l\'article 3. La présente norme ne traite pas des perturbations engendrées par le couplage capacitif ou inductif sur les câbles ou autres parties de l\'installation. D\'autres normes CEI traitant des perturbations conduites couvrent ces aspects. La présente norme a pour objet d\'établir une base commune et reproductible pour évaluer la performance des matériels électriques et électroniques à vocation domestique, commerciale ou industrielle lorsqu\'ils sont soumis à des champs magnétiques impulsionnels. La présente norme a pour objet de définir les éléments suivants: - les niveaux recommandés d\'essai; - le matériel d\'essai; - l\'installation d\'essai; - la procédure d\'essai.

Standards Relationship
IEC 61000-4-9:1993+AMD1:2000 CSV Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.