• Shopping Cart
    There are no items in your cart

CSA IEC 61558-2-2:20

Current

Current

The latest, up-to-date edition.

Safety of power transformers, power supplies, reactors and similar products — Part 2-2: Particular requirements and tests for control transformers and power supplies incorporating control transformers (Adopted CEI/IEC 61558-2-2:2007, second edition, 2007-01) | Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues — Partie 2-2 : Règles particulières et essais pour les transformateurs de commande et les alimentations incorporant les transformateurs de commande (norme CEI/IEC 61558-2-2:2007 adoptée, deuxième édition, 2007-01)

Available format(s)

Hardcopy , PDF

Language(s)

English - French

Published date

01-01-2020

€76.27
Excluding VAT

CSA Preface This is the second edition of CSA IEC 61558-2-2, Safety of power transformers, power supplies, reactors and similar products — Part 2-2: Particular requirements and tests for control transformers and power supplies incorporating control transformers, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61558-2-2 (second edition, 2007-01). It supersedes the previous edition published in 2003 as CAN/CSA-E61558-2-2 (adopted IEC 61558-2-2:1997), Safety of power transformers, power supply units and similar — Part 2-2: Particular requirements for control transformers. This Standard is intended to be used in conjunction with CAN/CSA-E61558-1:12, Safety of power transformers, power supplies, reactors and similar products — Part 1: General requirements and tests (adopted IEC 61558-1:2005+A1:2009, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope Replacement: This part of IEC 61558 deals with safety aspects of control transformers and power supplies incorporating control transformers such as electrical, thermal and mechanical safety. This Part 2-2 is applicable to control transformers and power supplies incorporating both control transformers and electronic circuits. This Part 2-2 is not applicable to external circuits and their components intended to be connected to the input terminals, output terminals or socket-outlets of the transformer and power supplies. This Part 2-2 does not apply to transformers covered by IEC 60076-11. This Part 2-2 applies to stationary or portable, single-phase or poly-phase, air-cooled (natural or forced), independent or associated control transformers and power supplies incorporating a control transformer, having a rated supply voltage not exceeding 1 000 V a.c. and rated supply and internal operating frequency not exceeding 500 Hz. The rated thermal output does not exceed: – 25 kVA for single-phase control transformers and power supplies incorporating control transformers; – 40 kVA for poly-phase control transformers and power supplies incorporating control transformers. This Part 2-2 is applicable to control transformers and power supplies incorporating control transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. This Part 2-2 is applicable to dry-type transformers. The windings may be encapsulated or non-encapsulated. The no-load output voltage or the rated output voltage does not exceed 1 000 V a.c. or 1 415 V ripple-free d.c. For independent control transformers and independent power supplies incorporating control transformers, the no-load output voltage and / or the rated output voltage is not less than 50 V a.c., or 120 V ripple free d.c. Control transformers covered by this Part 2-2 are used only in applications where double or reinforced insulation between circuits is not required by the installation rules or by the end product standard. NOTE 1 Normally, the control transformers and power supplies incorporating control transformers are intended to be used with equipment to provide voltages different from the supply voltage for the functional requirements of the equipment. The protection against electric shock may be provided (or completed) by other features of the equipment, such as the body. Parts of output circuits may be connected to the input circuits or to protective earth. This Part 2-2 is applicable to control transformers and power supplies incorporating control transformers associated with specific equipment, to the extent decided upon by the relevant IEC technical committees. NOTE 2 Attention is drawn to the following: – for control transformers and power supplies incorporating control transformers intended to be used in vehicles, on board ships and on board aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary; – measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered ; – the different conditions for transportation, storage, and operation of the control transformers and power supplies incorporating control transformers should also be considered; – additional requirements in accordance with other appropriate standards and national rules may be applicable to control transformers and power supplies incorporating control transformers intended for use in special environments, such as tropical environments. NOTE 3 Future technological development of control transformers and power supplies incorporating control transformers may necessitate a need to increase the upper limit of the frequencies, until then this Part 2-2 may be used as a guidance document. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de CSA IEC 61558-2-2, Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues — Partie 2-2 : Règles particulières et essais pour les transformateurs de commande et les alimentations incorporant les transformateurs de commande. Il s’agit de l’adoption, sans modification, de la norme IEC (Commission Électrotechnique Internationale) 61558-2-2 (deuxième édition, 2007-01), qui porte le même titre. Il remplace l’édition antérieure publiée en 2003 qui portait la désignation CAN/CSA-E61558-2-2 (norme IEC 61558-2-2:1997 adoptée), Sécurité des transformateurs, blocs d’alimentation et analogues — Partie 2-2 : Règles particulières pour les transformateurs de commande. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-E61558-1:12, Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues — Partie 1 : Exigences générales et essais (norme IEC 61558-1:2005+A1:2009 adoptée, avec exigences propres au Canada). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application Remplacement: La présente partie de la CEI 61558 traite des aspects relatifs à la sécurité des transformateurs de commande et des alimentations incorporant des transformateurs de commande tels que les aspects de sécurité électrique, thermique et mécanique. Cette Partie 2-2 est applicable aux transformateurs de commande et aux alimentations incorporant des transformateurs de commande et des circuits électroniques. Cette Partie 2-2 n\'est pas applicable aux circuits externes et à leurs composants destinés à être connectés aux bornes primaires, bornes secondaires ou socles des transformateurs et alimentations. Cette Partie 2-2 ne s\'applique pas aux transformateurs couverts par la CEI 60076-11. Cette Partie 2-2 s\'applique aux transformateurs de commande et alimentations incorporant des transformateurs de commande fixes ou mobiles, monophasés ou polyphasés, à refroidissement par air (naturel ou forcé) indépendants ou associés, ayant une tension primaire assignée ne dépassant pas 1 000 V en courant alternatif, une fréquence d’alimentation assignée et une fréquence de fonctionnement interne ne dépassant pas 500 Hz. La puissance thermique assignée ne doit pas dépasser: – 25 kVA pour les transformateurs de commande monophasés et les alimentations incorporant des transformateurs de commande ; – 40 kVA pour les transformateurs de commande polyphasés et les alimentations incorporant des transformateurs de commande. Cette Partie 2-2 est applicable aux transformateurs de commande et aux alimentations incorporant des transformateurs de commande sans limitation de la puissance assignée dans le cas d’un accord entre l\'acheteur et le constructeur. Cette Partie 2-2 est applicable aux transformateurs secs. Les enroulements peuvent être enrobés ou non enrobés. La tension secondaire à vide ou la tension secondaire assignée ne doit pas dépasser 1 000 V en courant alternatif ou 1 415 V en courant continu lissé. Pour les transformateurs de commande indépendants et les alimentations indépendantes incorporant des transformateurs de commande, la tension secondaire à vide n\'est pas inférieure à 50 V en courant alternatif, ou 120 V en courant continu lissé. Les transformateurs de commande couverts par cette Partie 2-2 sont utilisés uniquement dans les applications où l\'isolation double ou renforcée entre circuits n\'est pas requise par les règles d\'installation ou la norme du produit final. NOTE 1 Normalement, les transformateurs de commande et les alimentations incorporant des transformateurs de commande sont destinés à être utilisés avec des équipements pour procurer des tensions différentes de la tension du réseau pour satisfaire les exigences fonctionnelles de l’équipement. La protection contre les chocs électriques peut être fournie (ou complétée) par d’autres parties de l’équipement telles que la masse. Des parties de circuits secondaires peuvent être connectées aux circuits primaires ou à la terre de protection. Cette Partie 2-2 est applicable aux transformateurs de commande et aux alimentations incorporant des transformateurs de commande associés à des équipements spécifiques, suivant les exigences des comités techniques de la CEI correspondants. NOTE 2 L\'attention est attirée sur les points suivants: - pour les transformateurs de commande et les alimentations incorporant des transformateurs de commande destinés à être utilisés dans des véhicules, à bord de navires ou d\'avions, des exigences supplémentaires (venant d\'autres normes applicables, de règles nationales, etc.) peuvent être nécessaires ; - il convient également de prendre des mesures pour protéger l\'enveloppe et les composants à l\'intérieur de l\'enveloppe contre les influences externes telles que les champignons, la vermine, les termites, le rayonnement solaire et le givre ; - il convient également de prendre en considération les différentes conditions de transport, de stockage et de fonctionnement des transformateurs de commande et des alimentations incorporant des transformateurs de commande ; - des exigences supplémentaires en conformité avec les autres normes appropriées et règles nationales peuvent être appliquées aux transformateurs de commande et alimentations incorporant des transformateurs de commande destinés à être utilisés dans un environnement particulier, tel qu\'un environnement tropical. NOTE 3 Une augmentation de la limite supérieure des fréquences peut s\'avérer nécessaire pour des besoins de développement technique futur des transformateurs de commande et des alimentations incorporant des transformateurs de commande. Dans ce cas, cette Partie 2-2 peut être utilisée comme guide.

DocumentType
Standard
ISBN
978-1-4883-2953-1
Pages
48
ProductNote
THIS STANDARD ALSO REFERS TO CEI 61558-2-16
PublisherName
Canadian Standards Association
Status
Current
Supersedes

CSA Preface This is the second edition of CSA IEC 61558-2-2, Safety of power transformers, power supplies, reactors and similar products — Part 2-2: Particular requirements and tests for control transformers and power supplies incorporating control transformers, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61558-2-2 (second edition, 2007-01). It supersedes the previous edition published in 2003 as CAN/CSA-E61558-2-2 (adopted IEC 61558-2-2:1997), Safety of power transformers, power supply units and similar — Part 2-2: Particular requirements for control transformers. This Standard is intended to be used in conjunction with CAN/CSA-E61558-1:12, Safety of power transformers, power supplies, reactors and similar products — Part 1: General requirements and tests (adopted IEC 61558-1:2005+A1:2009, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope Replacement: This part of IEC 61558 deals with safety aspects of control transformers and power supplies incorporating control transformers such as electrical, thermal and mechanical safety. This Part 2-2 is applicable to control transformers and power supplies incorporating both control transformers and electronic circuits. This Part 2-2 is not applicable to external circuits and their components intended to be connected to the input terminals, output terminals or socket-outlets of the transformer and power supplies. This Part 2-2 does not apply to transformers covered by IEC 60076-11. This Part 2-2 applies to stationary or portable, single-phase or poly-phase, air-cooled (natural or forced), independent or associated control transformers and power supplies incorporating a control transformer, having a rated supply voltage not exceeding 1 000 V a.c. and rated supply and internal operating frequency not exceeding 500 Hz. The rated thermal output does not exceed: – 25 kVA for single-phase control transformers and power supplies incorporating control transformers; – 40 kVA for poly-phase control transformers and power supplies incorporating control transformers. This Part 2-2 is applicable to control transformers and power supplies incorporating control transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. This Part 2-2 is applicable to dry-type transformers. The windings may be encapsulated or non-encapsulated. The no-load output voltage or the rated output voltage does not exceed 1 000 V a.c. or 1 415 V ripple-free d.c. For independent control transformers and independent power supplies incorporating control transformers, the no-load output voltage and / or the rated output voltage is not less than 50 V a.c., or 120 V ripple free d.c. Control transformers covered by this Part 2-2 are used only in applications where double or reinforced insulation between circuits is not required by the installation rules or by the end product standard. NOTE 1 Normally, the control transformers and power supplies incorporating control transformers are intended to be used with equipment to provide voltages different from the supply voltage for the functional requirements of the equipment. The protection against electric shock may be provided (or completed) by other features of the equipment, such as the body. Parts of output circuits may be connected to the input circuits or to protective earth. This Part 2-2 is applicable to control transformers and power supplies incorporating control transformers associated with specific equipment, to the extent decided upon by the relevant IEC technical committees. NOTE 2 Attention is drawn to the following: – for control transformers and power supplies incorporating control transformers intended to be used in vehicles, on board ships and on board aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary; – measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered ; – the different conditions for transportation, storage, and operation of the control transformers and power supplies incorporating control transformers should also be considered; – additional requirements in accordance with other appropriate standards and national rules may be applicable to control transformers and power supplies incorporating control transformers intended for use in special environments, such as tropical environments. NOTE 3 Future technological development of control transformers and power supplies incorporating control transformers may necessitate a need to increase the upper limit of the frequencies, until then this Part 2-2 may be used as a guidance document. -------------------------------------------------------------------------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de CSA IEC 61558-2-2, Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues — Partie 2-2 : Règles particulières et essais pour les transformateurs de commande et les alimentations incorporant les transformateurs de commande. Il s’agit de l’adoption, sans modification, de la norme IEC (Commission Électrotechnique Internationale) 61558-2-2 (deuxième édition, 2007-01), qui porte le même titre. Il remplace l’édition antérieure publiée en 2003 qui portait la désignation CAN/CSA-E61558-2-2 (norme IEC 61558-2-2:1997 adoptée), Sécurité des transformateurs, blocs d’alimentation et analogues — Partie 2-2 : Règles particulières pour les transformateurs de commande. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-E61558-1:12, Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues — Partie 1 : Exigences générales et essais (norme IEC 61558-1:2005+A1:2009 adoptée, avec exigences propres au Canada). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application Remplacement: La présente partie de la CEI 61558 traite des aspects relatifs à la sécurité des transformateurs de commande et des alimentations incorporant des transformateurs de commande tels que les aspects de sécurité électrique, thermique et mécanique. Cette Partie 2-2 est applicable aux transformateurs de commande et aux alimentations incorporant des transformateurs de commande et des circuits électroniques. Cette Partie 2-2 n\'est pas applicable aux circuits externes et à leurs composants destinés à être connectés aux bornes primaires, bornes secondaires ou socles des transformateurs et alimentations. Cette Partie 2-2 ne s\'applique pas aux transformateurs couverts par la CEI 60076-11. Cette Partie 2-2 s\'applique aux transformateurs de commande et alimentations incorporant des transformateurs de commande fixes ou mobiles, monophasés ou polyphasés, à refroidissement par air (naturel ou forcé) indépendants ou associés, ayant une tension primaire assignée ne dépassant pas 1 000 V en courant alternatif, une fréquence d’alimentation assignée et une fréquence de fonctionnement interne ne dépassant pas 500 Hz. La puissance thermique assignée ne doit pas dépasser: – 25 kVA pour les transformateurs de commande monophasés et les alimentations incorporant des transformateurs de commande ; – 40 kVA pour les transformateurs de commande polyphasés et les alimentations incorporant des transformateurs de commande. Cette Partie 2-2 est applicable aux transformateurs de commande et aux alimentations incorporant des transformateurs de commande sans limitation de la puissance assignée dans le cas d’un accord entre l\'acheteur et le constructeur. Cette Partie 2-2 est applicable aux transformateurs secs. Les enroulements peuvent être enrobés ou non enrobés. La tension secondaire à vide ou la tension secondaire assignée ne doit pas dépasser 1 000 V en courant alternatif ou 1 415 V en courant continu lissé. Pour les transformateurs de commande indépendants et les alimentations indépendantes incorporant des transformateurs de commande, la tension secondaire à vide n\'est pas inférieure à 50 V en courant alternatif, ou 120 V en courant continu lissé. Les transformateurs de commande couverts par cette Partie 2-2 sont utilisés uniquement dans les applications où l\'isolation double ou renforcée entre circuits n\'est pas requise par les règles d\'installation ou la norme du produit final. NOTE 1 Normalement, les transformateurs de commande et les alimentations incorporant des transformateurs de commande sont destinés à être utilisés avec des équipements pour procurer des tensions différentes de la tension du réseau pour satisfaire les exigences fonctionnelles de l’équipement. La protection contre les chocs électriques peut être fournie (ou complétée) par d’autres parties de l’équipement telles que la masse. Des parties de circuits secondaires peuvent être connectées aux circuits primaires ou à la terre de protection. Cette Partie 2-2 est applicable aux transformateurs de commande et aux alimentations incorporant des transformateurs de commande associés à des équipements spécifiques, suivant les exigences des comités techniques de la CEI correspondants. NOTE 2 L\'attention est attirée sur les points suivants: - pour les transformateurs de commande et les alimentations incorporant des transformateurs de commande destinés à être utilisés dans des véhicules, à bord de navires ou d\'avions, des exigences supplémentaires (venant d\'autres normes applicables, de règles nationales, etc.) peuvent être nécessaires ; - il convient également de prendre des mesures pour protéger l\'enveloppe et les composants à l\'intérieur de l\'enveloppe contre les influences externes telles que les champignons, la vermine, les termites, le rayonnement solaire et le givre ; - il convient également de prendre en considération les différentes conditions de transport, de stockage et de fonctionnement des transformateurs de commande et des alimentations incorporant des transformateurs de commande ; - des exigences supplémentaires en conformité avec les autres normes appropriées et règles nationales peuvent être appliquées aux transformateurs de commande et alimentations incorporant des transformateurs de commande destinés à être utilisés dans un environnement particulier, tel qu\'un environnement tropical. NOTE 3 Une augmentation de la limite supérieure des fréquences peut s\'avérer nécessaire pour des besoins de développement technique futur des transformateurs de commande et des alimentations incorporant des transformateurs de commande. Dans ce cas, cette Partie 2-2 peut être utilisée comme guide.

Standards Relationship
IEC 61558-2-2:2007 Identical