CSA IEC 61558-2-4:20
Current
The latest, up-to-date edition.
Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V — Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers (Adopted IEC 61558-2-4:2009, second edition 2009-02) | Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et produits analogues pour des tensions d’alimentation jusqu’à 1 100 V — Partie 2-4: Règles particulières et essais pour les transformateurs de séparation des circuits et les blocs d’alimentation incorporant des transformateurs de séparation des circuits (norme IEC 61558-2-4:2009 adoptée, deuxième édition, 2009-02)
Hardcopy , PDF
English - French
01-01-2020
CSA Preface This is the second edition of CSA IEC 61558-2-4, Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100V — Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61558-2-4 (second edition, 2009-02). It supersedes the previous edition published in 2003 as CAN/CSA-E61558-2-4 (adopted IEC 61558-2-4:1997), Safety of power transformers, power supply units and similar — Part 2: Particular requirements for isolating transformers for general use. This Standard is intended to be used in conjunction with CAN/CSA-E61558-1:12, Safety of power transformers, power supplies, reactors and similar products — Part 1: General requirements and tests (adopted IEC 61558-1:2005+A1:2009, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope Replacement: This part of IEC 61558 deals with the safety of isolating transformers for general applications and power supply units incorporating isolating transformers for general applications. Transformers incorporating electronic circuits are also covered by this standard. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers isolating transformers for general applications and power supply units incorporating isolating transformers for general applications. NOTE 2 For power supply units (linear) this part is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this part. This part is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry- type transformers. The windings may be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 100 V a.c., and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated output does not exceed: – 25 kVA for single-phase transformers; – 40 kVA for polyphase transformers. This part is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 3 Transformers intended to supply distribution networks are not included in the scope. The no-load output voltage or the rated output voltage does exceed 50 V a.c. or 120 V ripple-free d.c., and where applicable, does not exceed 500 V a.c. or 708 V ripple-free d.c. The no-load output voltage and the rated output voltage may be up to 1 000 V a.c. or 1 415 V ripple-free d.c. for special applications. This part is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the end product standard. NOTE 4 Attention is drawn to the following: - for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary; - measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered; - the different conditions for transportation, storage, and operation of the transformers should also be considered; - additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments. NOTE 5 Future technological development of transformers may necessitate a need to increase the upper limit of the frequencies, until then this part may be used as a guidance document. --------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de CSA IEC 61558-2-4, Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et produits analogues pour des tensions d’alimentation jusqu’à 1 100 V — Partie 2-4 : Règles particulières et essais pour les transformateurs de séparation des circuits et les blocs d’alimentation incorporant des transformateurs de séparation des circuits. Il s’agit de l’adoption, sans modification, de la norme IEC (Commission Électrotechnique Internationale) 61558-2-4 (deuxième édition, 2009-02), qui porte le même titre. Il remplace l’édition antérieure publiée en 2003 qui portait la désignation CAN/CSA-E61558-2-4 (norme IEC 61558-2-4:1997 adoptée), Sécurité des transformateurs, blocs d’alimentation et analogues — Partie 2 : Règles particulières pour les transformateurs de séparation des circuits pour usage général. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-E61558-1:12, Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues — Partie 1 : Exigences générales et essais (norme IEC 61558-1:2005+A1:2009 adoptée, avec exigences propres au Canada). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application Remplacement: La présente partie de la CEI 61558 traite de la sécurité des transformateurs de séparation des circuits pour applications d’ordre général et des blocs d’alimentation incorporant des transformateurs de séparation des circuits pour applications d’ordre général. Les transformateurs incorporant des circuits électroniques sont également couverts par cette norme. NOTE 1 La sécurité comprend les aspects électrique, thermique et mécanique. Sauf spécification contraire, dans la suite de ce document, le terme transformateur couvre les transformateurs de séparation des circuits pour applications d\'ordre général et les blocs d\'alimentation incorporant des transformateurs de séparation des circuits pour application d\'ordre général. NOTE 2 Pour les blocs d’alimentation (linéaires) cette partie est applicable. Pour les blocs d’alimentation à découpage, la CEI 61558-2-16 s’applique conjointement avec cette partie. La présente partie s’applique aux transformateurs secs fixes ou mobiles, monophasés ou polyphasés, à refroidissement par air (naturel ou forcé) indépendants ou associés. Les enroulements peuvent être enrobés ou non enrobés. La tension primaire assignée ne dépasse pas 1 100 V courant alternatif, et la fréquence primaire assignée et les fréquences de fonctionnement interne ne dépassent pas 500 Hz. La puissance assignée ne dépasse pas: – 25 kVA pour les transformateurs monophasés; – 40 kVA pour les transformateurs polyphasés. La présente partie est applicable aux transformateurs sans limitation de puissance assignée, objet d’un accord entre l’acheteur et le constructeur. NOTE 3 Les transformateurs destinés à alimenter les réseaux de distribution ne font pas partie du domaine d’application. La tension secondaire à vide ou la tension secondaire assignée dépasse 50 V courant alternatif ou 120 V courant continu lissé, et lorsque cela est applicable, elle ne dépasse pas 500 V courant alternatif ou 708 V courant continu lissé. La tension secondaire à vide et la tension secondaire assignée peuvent atteindre 1 000 V courant alternatif ou 1 415 V courant continu lissé pour des applications spéciales. La présente partie n\'est pas applicable aux circuits externes et à leurs composants destinés à être connectés aux bornes primaires et bornes secondaires des transformateurs. Les transformateurs couverts par la présente partie sont utilisés dans les applications où la double isolation ou l’isolation renforcée entre circuits est exigée par les règles d\'installation ou par la norme du produit final. NOTE 4 L\'attention est attirée sur les points suivants: – pour les transformateurs destinés à être utilisés dans des véhicules, à bord de navires et d\'avions, des exigences supplémentaires (venant d\'autres normes applicables, de règles nationales, etc) peuvent être nécessaires; – il convient également de prendre des mesures pour protéger l\'enveloppe et les composants à l\'intérieur de l\'enveloppe contre les influences externes telles que les champignons, la vermine, les termites, le rayonnement solaire et le givre; – Il convient également de prendre en considération les différentes conditions de transport, de stockage et de fonctionnement des transformateurs; – des exigences supplémentaires en conformité avec les autres normes appropriées et règles nationales peuvent être appliquées aux transformateurs destinés à être utilisés dans un environnement particulier. NOTE 5 Une augmentation de la limite supérieure des fréquences peut s\'avérer nécessaire pour des besoins de développement technique futur des transformateurs. Jusque là, la présente partie peut être utilisée comme un guide.
DocumentType |
Standard
|
ISBN |
978-1-4883-2954-8
|
Pages |
49
|
PublisherName |
Canadian Standards Association
|
Status |
Current
|
Supersedes |
CSA Preface This is the second edition of CSA IEC 61558-2-4, Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100V — Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers, which is an adoption without modification of the identically titled IEC (International Electrotechnical Commission) Standard 61558-2-4 (second edition, 2009-02). It supersedes the previous edition published in 2003 as CAN/CSA-E61558-2-4 (adopted IEC 61558-2-4:1997), Safety of power transformers, power supply units and similar — Part 2: Particular requirements for isolating transformers for general use. This Standard is intended to be used in conjunction with CAN/CSA-E61558-1:12, Safety of power transformers, power supplies, reactors and similar products — Part 1: General requirements and tests (adopted IEC 61558-1:2005+A1:2009, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope Replacement: This part of IEC 61558 deals with the safety of isolating transformers for general applications and power supply units incorporating isolating transformers for general applications. Transformers incorporating electronic circuits are also covered by this standard. NOTE 1 Safety includes electrical, thermal and mechanical aspects. Unless otherwise specified, from here onward, the term transformer covers isolating transformers for general applications and power supply units incorporating isolating transformers for general applications. NOTE 2 For power supply units (linear) this part is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this part. This part is applicable to stationary or portable, single-phase or polyphase, air-cooled (natural or forced) independent or associated dry- type transformers. The windings may be encapsulated or non-encapsulated. The rated supply voltage does not exceed 1 100 V a.c., and the rated supply frequency and the internal operating frequencies do not exceed 500 Hz. The rated output does not exceed: – 25 kVA for single-phase transformers; – 40 kVA for polyphase transformers. This part is applicable to transformers without limitation of the rated output subject to an agreement between the purchaser and the manufacturer. NOTE 3 Transformers intended to supply distribution networks are not included in the scope. The no-load output voltage or the rated output voltage does exceed 50 V a.c. or 120 V ripple-free d.c., and where applicable, does not exceed 500 V a.c. or 708 V ripple-free d.c. The no-load output voltage and the rated output voltage may be up to 1 000 V a.c. or 1 415 V ripple-free d.c. for special applications. This part is not applicable to external circuits and their components intended to be connected to the input terminals and output terminals of the transformers. Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the end product standard. NOTE 4 Attention is drawn to the following: - for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary; - measures to protect the enclosure and the components inside the enclosure against external influences such as fungus, vermin, termites, solar-radiation, and icing should also be considered; - the different conditions for transportation, storage, and operation of the transformers should also be considered; - additional requirements in accordance with other appropriate standards and national rules may be applicable to transformers intended for use in special environments. NOTE 5 Future technological development of transformers may necessitate a need to increase the upper limit of the frequencies, until then this part may be used as a guidance document. --------------------------------------------------------------- Préface CSA Ce document constitue la deuxième édition de CSA IEC 61558-2-4, Sécurité des transformateurs, bobines d’inductance, blocs d’alimentation et produits analogues pour des tensions d’alimentation jusqu’à 1 100 V — Partie 2-4 : Règles particulières et essais pour les transformateurs de séparation des circuits et les blocs d’alimentation incorporant des transformateurs de séparation des circuits. Il s’agit de l’adoption, sans modification, de la norme IEC (Commission Électrotechnique Internationale) 61558-2-4 (deuxième édition, 2009-02), qui porte le même titre. Il remplace l’édition antérieure publiée en 2003 qui portait la désignation CAN/CSA-E61558-2-4 (norme IEC 61558-2-4:1997 adoptée), Sécurité des transformateurs, blocs d’alimentation et analogues — Partie 2 : Règles particulières pour les transformateurs de séparation des circuits pour usage général. Cette norme est conçue pour être utilisée de concert avec CAN/CSA-E61558-1:12, Sécurité des transformateurs, alimentations, bobines d’inductance et produits analogues — Partie 1 : Exigences générales et essais (norme IEC 61558-1:2005+A1:2009 adoptée, avec exigences propres au Canada). Cette norme a été élaborée conformément aux exigences du Conseil canadien des normes concernant les Normes nationales du Canada. Cette norme a été publiée en tant que Norme nationale du Canada par Groupe CSA. Domaine d’application Remplacement: La présente partie de la CEI 61558 traite de la sécurité des transformateurs de séparation des circuits pour applications d’ordre général et des blocs d’alimentation incorporant des transformateurs de séparation des circuits pour applications d’ordre général. Les transformateurs incorporant des circuits électroniques sont également couverts par cette norme. NOTE 1 La sécurité comprend les aspects électrique, thermique et mécanique. Sauf spécification contraire, dans la suite de ce document, le terme transformateur couvre les transformateurs de séparation des circuits pour applications d\'ordre général et les blocs d\'alimentation incorporant des transformateurs de séparation des circuits pour application d\'ordre général. NOTE 2 Pour les blocs d’alimentation (linéaires) cette partie est applicable. Pour les blocs d’alimentation à découpage, la CEI 61558-2-16 s’applique conjointement avec cette partie. La présente partie s’applique aux transformateurs secs fixes ou mobiles, monophasés ou polyphasés, à refroidissement par air (naturel ou forcé) indépendants ou associés. Les enroulements peuvent être enrobés ou non enrobés. La tension primaire assignée ne dépasse pas 1 100 V courant alternatif, et la fréquence primaire assignée et les fréquences de fonctionnement interne ne dépassent pas 500 Hz. La puissance assignée ne dépasse pas: – 25 kVA pour les transformateurs monophasés; – 40 kVA pour les transformateurs polyphasés. La présente partie est applicable aux transformateurs sans limitation de puissance assignée, objet d’un accord entre l’acheteur et le constructeur. NOTE 3 Les transformateurs destinés à alimenter les réseaux de distribution ne font pas partie du domaine d’application. La tension secondaire à vide ou la tension secondaire assignée dépasse 50 V courant alternatif ou 120 V courant continu lissé, et lorsque cela est applicable, elle ne dépasse pas 500 V courant alternatif ou 708 V courant continu lissé. La tension secondaire à vide et la tension secondaire assignée peuvent atteindre 1 000 V courant alternatif ou 1 415 V courant continu lissé pour des applications spéciales. La présente partie n\'est pas applicable aux circuits externes et à leurs composants destinés à être connectés aux bornes primaires et bornes secondaires des transformateurs. Les transformateurs couverts par la présente partie sont utilisés dans les applications où la double isolation ou l’isolation renforcée entre circuits est exigée par les règles d\'installation ou par la norme du produit final. NOTE 4 L\'attention est attirée sur les points suivants: – pour les transformateurs destinés à être utilisés dans des véhicules, à bord de navires et d\'avions, des exigences supplémentaires (venant d\'autres normes applicables, de règles nationales, etc) peuvent être nécessaires; – il convient également de prendre des mesures pour protéger l\'enveloppe et les composants à l\'intérieur de l\'enveloppe contre les influences externes telles que les champignons, la vermine, les termites, le rayonnement solaire et le givre; – Il convient également de prendre en considération les différentes conditions de transport, de stockage et de fonctionnement des transformateurs; – des exigences supplémentaires en conformité avec les autres normes appropriées et règles nationales peuvent être appliquées aux transformateurs destinés à être utilisés dans un environnement particulier. NOTE 5 Une augmentation de la limite supérieure des fréquences peut s\'avérer nécessaire pour des besoins de développement technique futur des transformateurs. Jusque là, la présente partie peut être utilisée comme un guide.
Standards | Relationship |
IEC 61558-2-4:2009 | Identical |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.