CSA S413 : 2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
PARKING STRUCTURES
Hardcopy , PDF
16-11-2019
English
01-01-2014
Preface
0 Introduction
1 Scope
2 Reference publications
3 Definitions
4 Corrosion and leakage protection
5 Drawings and related documents
6 Materials
7 Design requirements
8 Additional requirements for cast-in-place, post-tensioned
concrete construction
9 Additional requirements for steel structures
10 Construction
11 Inspection and testing
12 Maintenance
Annex A (informative) - Moisture barriers
Annex B (informative) - Cathodic protection
Annex C (informative) - Corrosion inhibitors
Annex D (informative) - Testing and inspection
Annex E (informative) - Maintenance
Annex F (informative) - Responsibilities
Annex G (informative) - Structural considerations
Annex H (informative) - Commentary
Defines special requirements for the durability aspects of the design and construction of new parking structures and parts of buildings subject to vehicular traffic.
DocumentType |
Standard
|
Pages |
130
|
PublisherName |
Canadian Standards Association
|
Status |
Superseded
|
Supersedes |
ACI SP 315 : 2017 | ACI/FIB INTERNATIONAL SYMPOSIUM ON PUNCHING SHEAR IN STRUCTURAL CONCRETE SLABS: HONORING NEIL M. HAWKINS |
CSA S448.1 : 2010 : R2015 | REPAIR OF REINFORCED CONCRETE IN BUILDINGS AND PARKING STRUCTURES |
CSA S448.1 : 2010 | REPAIR OF REINFORCED CONCRETE IN BUILDINGS AND PARKING STRUCTURES |
C22.1-15 PACKAGE | Consists of C22.1-15, Canadian electrical code, part I (23rd edition), safety standard for electrical installations; C22.1HB-15, Canadian electrical code handbook - an explanation of rules of the Canadian electrical code, part I and the 2015 Electrical quick reference |
C22.1HB-18 | Canadian Electrical Code Handbook - An Explanation of the Rules of the Canadian Electrical Code, Part I |
CSA A23.4-A251 : 0 | PRECAST CONCRETE - MATERIALS AND CONSTRUCTION/QUALIFICATION CODE FOR ARCHITECTURAL AND STRUCTURAL PRECAST CONCRETE PRODUCTS |
CSA S806: 2012 | DESIGN AND CONSTRUCTION OF BUILDING STRUCTURES WITH FIBRE-REINFORCED POLYMERS |
CSA CE CODE SAFETY PACKAGE : 2012 | CE CODE SAFETY PACKAGE |
CSA A23.4 : 2016 | PRECAST CONCRETE - MATERIALS AND CONSTRUCTION |
CSA S478 : 0 | GUIDELINE ON DURABILITY OF BUILDINGS |
CSA A23.1 A23.2 : 2014 | CONCRETE MATERIALS AND METHODS OF CONCRETE CONSTRUCTION/TEST METHODS AND STANDARD PRACTICES FOR CONCRETE |
ASTM A 518/A518M : 1999 | Standard Specification for Corrosion-Resistant High-Silicon Iron Castings |
ACI PRC-308 : 2016 | GUIDE TO EXTERNAL CURING OF CONCRETE |
ACI 362.1R : 2012 | GUIDE FOR THE DESIGN AND CONSTRUCTION OF DURABLE CONCRETE PARKING STRUCTURES |
ACI SP 126 : 1991 | DURABILITY OF CONCRETE |
NACE 01102 : 0 | STATE-OF-THE-ART REPORT: CRITERIA FOR CATHODIC PROTECTION OF PRESTRESSED CONCRETE STRUCTURES |
ACI SP 151 : 1994 | CONCRETE BRIDGES IN AGGRESSIVE ENVIRONMENTS |
ACI SP 100 : 1987 | CONCRETE DURABILITY - PROCEEDINGS OF THE KATHARINE AND BRYANT MATHER INTERNATIONAL SYMPOSIUM |
ASTM A 123/A123M : 2017 : REDLINE | Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products |
CGSB 37.68 : M87 | MASTIC ASPHALT (HOT PROCESS) FOR WATERPROOFING |
CSA A3000 : 2013 | CEMENTITIOUS MATERIALS COMPENDIUM |
ISO 12944-5:2007 | Paints and varnishes Corrosion protection of steel structures by protective paint systems Part 5: Protective paint systems |
CSA S16 : 2014 | DESIGN OF STEEL STRUCTURES |
ACI 224.3R : 1995 | JOINTS IN CONCRETE CONSTRUCTION |
CGSB 37.51 : M90 | APPLICATION FOR HOT-APPLIED RUBBERIZED ASPHALT, FOR ROOFING AND WATERPROOFING |
CGSB 37.65 : M88 | MASTIC ASPHALT (HOT PROCESS) FOR FLOORING |
CGSB 37.50 : M89 | HOT APPLIED, RUBBERIZED ASPHALT FOR ROOFING AND WATERPROOFING |
NACE SP 01 87 : 2017 | DESIGN FOR CORROSION CONTROL OF REINFORCING STEEL IN CONCRETE |
ACI SP 113 : 1989 | CRACKING IN PRESTRESSED CONCRETE STRUCTURES |
ACI SP 65 : 1980 | PERFORMANCE OF CONCRETE IN MARINE ENVIRONMENTS |
ASTM C 957/C957M : 2017 : REDLINE | Standard Specification for High-Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane With Integral Wearing Surface |
CSA A23.4 : 2016 | PRECAST CONCRETE - MATERIALS AND CONSTRUCTION |
NACE SP 02 90 : 2007 | IMPRESSED CURRENT CATHODIC PROTECTION OF REINFORCING STEEL IN ATMOSPHERICALLY EXPOSED CONCRETE STRUCTURES |
CSA S478 : 0 | GUIDELINE ON DURABILITY OF BUILDINGS |
ASTM G 180 : 2013 : REDLINE | TEST METHOD FOR CORROSION INHIBITING ADMIXTURES FOR STEEL IN CONCRETE BY POLARIZATION RESISTANCE IN CEMENTITIOUS SLURRIES |
ASTM C 876 : 2015 : REDLINE | Standard Test Method for Corrosion Potentials of Uncoated Reinforcing Steel in Concrete |
ACI 318M : 2014 | BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318M-14) AND COMMENTARY (ACI 318RM-14) |
ACI 224R : 2001 | CONTROL OF CRACKING OF CONCRETE STRUCTURES |
NACE TM 02 94 : 2016 | TESTING OF EMBEDDABLE IMPRESSED CURRENT ANODES FOR USE IN CATHODIC PROTECTION OF ATMOSPHERICALLY EXPOSED STEEL-REINFORCED CONCRETE |
ACI 222R : 2001 | PROTECTION OF METALS IN CONCRETE AGAINST CORROSION |
ACI 515.2R : 2013 | GUIDE TO SELECTING PROTECTIVE TREATMENTS FOR CONCRETE |
ASTM D 4263 : 1983 : R2018 | Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method |
ACI 423.7 : 2014 | SPECIFICATION FOR UNBONDED SINGLE-STRAND TENDON MATERIALS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.